Biomass burning (BB) is a significant source of atmospheric particles in many parts of the world. Whereas many studies have demonstrated the importance of BB emissions in central and northern Europe, especially in rural areas, its impact in urban air quality of southern European countries has been sparsely investigated. In this study, highly time resolved multi-wavelength absorption coefficients together with levoglucosan (BB tracer) mass concentrations were combined to apportion carbonaceous aerosol sources. TheAethalometer model takes advantage of the different spectral behaviour of BB and fossil fuel (FF) combustion aerosols. The model was found to be more sensitive to the assumed value of the aerosol Ångström exponent (AAE) for FF (AAEff) than to the AAE for BB (AAEbb). As result of various sensitivity tests the model was optimized with AAEff = 1.1 and AAEbb = 2. The Aethalometer model and levoglucosan tracer estimates were in good agreement. The Aethalometer model was further applied to data from three sites in Granada urban area to evaluate the spatial variation of CMff and CMbb (carbonaceous matter from FF or BB origin, respectively) concentrations within the city. The results showed that CMbb was lower in the city centre while it has an unexpected profound impact on the CM levels measured in the suburbs (about 40%). Analysis of BB tracers with respect to wind speed suggested that BB was dominated by sources outside the city, to the west in a rural area. Distinguishing whether it corresponds to agricultural waste burning or with biomass burning for domestic heating was not possible. This study also shows that although traffic restrictions measures contribute to reduce carbonaceous concentrations, the extent of the reduction is very local. Other sources such as BB, which can contribute to CM as much as traffic emissions, should be targeted to reduce air pollution.
Abstract. Radiation fog occurs over many locations around the world in stable atmospheric conditions. Air traffic at busy airports can be significantly disrupted because low visibility at the ground makes it unsafe to take off, land and taxi on the ground. Current numerical weather prediction forecasts are able to predict general conditions favorable for fog formation, but not the exact time or location of fog occurrence. A selected set of observations available in near-real time at strategic locations could also be useful to track the evolution of key processes and key parameters that drive fog formation. Such observations could complement the information predicted by numerical weather prediction (NWP) models that is made available to airport forecasters in support of their fog forecast. This paper presents an experimental setup based on collocated automatic lidar and ceilometer measurements, relative humidity measurements and horizontal visibility measurements to study hygroscopic growth of fog condensation nuclei. This process can take several minutes to hours, and can be tracked using lidar-or ceilometer-attenuated backscatter profiles. Based on hygroscopic growth laws we derive a set of parameters that can be used to provide alerts minutes to hours prior to formation of radiation fog. We present an algorithm that uses the temporal evolution of attenuated backscatter measurements to derive pre-fog formation alerts. The performance of the algorithm is tested on 45 independent pre-fog situations at two locations (near Paris, France, and Brussels, Belgium). We find that an alert for pre-fog conditions predominantly occurs 10-50 min prior to fog formation at an altitude ranging 0 to 100 m above ground. In a few cases, alerts can occur up to 100 min prior to fog formation. Alert durations are found to be sensitive to the relative humidity conditions found a few hours prior to the fog.
In this paper we present an approach for the profiling of aerosol microphysical and optical properties combining ceilometer and sun/sky photometer measurements in the GRASP code (General Retrieval of Aerosol and Surface Properties). For this objective, GRASP is used with sun/sky photometer measurements of aerosol optical depth (AOD) and sky radiances, both at four wavelengths and obtained from AErosol RObotic NETwork (AERONET), and ceilometer measurements of range corrected signal (RCS) at 1064 nm. A sensitivity study with synthetic data evidences the capability of the method to retrieve aerosol properties such as size distribution and profiles of volume concentration (VC), especially for coarse particles. Aerosol properties obtained by the mentioned method are compared with airborne in-situ measurements acquired during two flights over Granada (Spain) within the framework of ChArMEx/ADRIMED (Chemistry-Aerosol Mediterranean Experiment/Aerosol Direct Radiative Impact on the regional climate in the MEDiterranean region) 2013 campaign. The retrieved aerosol VC profiles agree well with the airborne measurements, showing a mean bias error (MBE) and a mean absolute bias error (MABE) of 0.3 µm 3 /cm 3 (12%) and 5.8 µm 3 /cm 3 (25%), respectively. The differences between retrieved VC and airborne in-situ measurements are within the uncertainty of GRASP retrievals. In addition, the retrieved VC at 2500 m a.s.l. is shown and compared with in-situ measurements obtained during summer 2016 at a high-atitude mountain station in the framework of the SLOPE I campaign (Sierra Nevada Lidar AerOsol Profiling Experiment). VC from GRASP presents high correlation (r=0.91) with the in-situ measurements, but overestimates them, MBE and MABE being equal to 23% and 43%.
Abstract. This study focuses on the analysis of aerosol hygroscopic growth during the Sierra Nevada Lidar AerOsol Profiling Experiment (SLOPE I) campaign by using the synergy of active and passive remote sensors at the ACTRIS Granada station and in situ instrumentation at a mountain station (Sierra Nevada, SNS). To this end, a methodology based on simultaneous measurements of aerosol profiles from an EARLINET multi-wavelength Raman lidar (RL) and relative humidity (RH) profiles obtained from a multi-instrumental approach is used. This approach is based on the combination of calibrated water vapor mixing ratio (r) profiles from RL and continuous temperature profiles from a microwave radiometer (MWR) for obtaining RH profiles with a reasonable vertical and temporal resolution. This methodology is validated against the traditional one that uses RH from colocated radiosounding (RS) measurements, obtaining differences in the hygroscopic growth parameter (γ ) lower than 5 % between the methodology based on RS and the one presented here. Additionally, during the SLOPE I campaign the remote sensing methodology used for aerosol hygroscopic growth studies has been checked against Mie calculations of aerosol hygroscopic growth using in situ measurements of particle number size distribution and submicron chemical composition measured at SNS. The hygroscopic case observed during SLOPE I showed an increase in the particle backscatter coefficient at 355 and 532 nm with relative humidity (RH ranged between 78 and 98 %), but also a decrease in the backscatter-related Ångström exponent (AE) and particle linear depolarization ratio (PLDR), indicating that the particles became larger and more spherical due to hygroscopic processes. Vertical and horizontal wind analysis is performed by means of a co-located Doppler lidar system, in order to evaluate the horizontal and vertical dynamics of the air masses. Finally, the Hänel parameterizaPublished by Copernicus Publications on behalf of the European Geosciences Union. 7002A. E. Bedoya-Velásquez et al.: Hygroscopic growth study in the framework of the SLOPE I campaign tion is applied to experimental data for both stations, and we found good agreement on γ measured with remote sensing (γ 532 = 0.48 ± 0.01 and γ 355 = 0.40 ± 0.01) with respect to the values calculated using Mie theory (γ 532 = 0.53 ± 0.02 and γ 355 = 0.45 ± 0.02), with relative differences between measurements and simulations lower than 9 % at 532 nm and 11 % at 355 nm.
Abstract. The interest in the use of ceilometers for optical aerosol characterization has increased in the last few years. They operate continuously almost unattended and are also much less expensive than lidars; hence, they can be distributed in dense networks over large areas. However, due to the low signal-to-noise ratio it is not always possible to obtain particle backscatter coefficient profiles, and the vast number of data generated require an automated and unsupervised method that ensures the quality of the profiles inversions.In this work we describe a method that uses aerosol optical depth (AOD) measurements from the AERONET network that it is applied for the calibration and automated quality assurance of inversion of ceilometer profiles. The method is compared with independent inversions obtained by colocated multiwavelength lidar measurements. A difference smaller than 15 % in backscatter is found between both instruments. This method is continuously and automatically applied to the Iberian Ceilometer Network (ICENET) and a case example during an unusually intense dust outbreak affecting the Iberian Peninsula between 20 and 24 February 2016 is shown. Results reveal that it is possible to obtain quantitative optical aerosol properties (particle backscatter coefficient) and discriminate the quality of these retrievals with ceilometers over large areas. This information has a great potential for alert systems and model assimilation and evaluation.
Abstract. This study evaluates the potential of the GRASP algorithm (Generalized Retrieval of Aerosol and Surface Properties) to retrieve continuous day-to-night aerosol properties, both column-integrated and vertically resolved. The study is focused on the evaluation of GRASP retrievals during an intense Saharan dust event that occurred during the Sierra Nevada Lidar aerOsol Profiling Experiment I (SLOPE I) field campaign. For daytime aerosol retrievals, we combined the measurements of the ground-based lidar from EARLINET (European Aerosol Research Lidar Network) station and sun–sky photometer from AERONET (Aerosol Robotic Network), both instruments co-located in Granada (Spain). However, for night-time retrievals three different combinations of active and passive remote-sensing measurements are proposed. The first scheme (N0) uses lidar night-time measurements in combination with the interpolation of sun–sky daytime measurements. The other two schemes combine lidar night-time measurements with night-time aerosol optical depth obtained by lunar photometry either using intensive properties of the aerosol retrieved during sun–sky daytime measurements (N1) or using the Moon aureole radiance obtained by sky camera images (N2). Evaluations of the columnar aerosol properties retrieved by GRASP are done versus standard AERONET retrievals. The coherence of day-to-night evolutions of the different aerosol properties retrieved by GRASP is also studied. The extinction coefficient vertical profiles retrieved by GRASP are compared with the profiles calculated by the Raman technique at night-time with differences below 30 % for all schemes at 355, 532 and 1064 nm. Finally, the volume concentration and scattering coefficient retrieved by GRASP at 2500 m a.s.l. are evaluated by in situ measurements at this height at Sierra Nevada Station. The differences between GRASP and in situ measurements are similar for the different schemes, with differences below 30 % for both volume concentration and scattering coefficient. In general, for the scattering coefficient, the GRASP N0 and N1 show better results than the GRASP N2 schemes, while for volume concentration, GRASP N2 shows the lowest differences against in situ measurements (around 10 %) for high aerosol optical depth values.
A large part of the European population is still exposed to ambient nitrogen dioxide (NO) levels exceeding the European Union (EU) air quality standards, being a key challenge to reduce NO concentrations across many European urban areas, particularly close to roads. In this work, a trend analysis of pollutants involved in NO processes was done for the period 2003-2014 in traffic sites from three Spanish cities (Barcelona, Madrid and Granada) that still exceed the European NO air quality standard limits. We also estimated the contributions of primary NO emissions and photo-chemically formed NO to the observed ambient NO concentrations in order to explore their possible role in the observed NO concentration trends. The NO and NO concentrations at these traffic sites showed significant decreasing trends during the period 2003-2014, especially at Barcelona (BAR) and Madrid (MAD) traffic stations. The NO concentrations showed statistically significant downward trends at BAR and MAD and remained unchanged at Granada traffic station (GRA) during the study period. Despite the significant decrease in NO concentrations in BCN and MAD during the analysed period, the NO concentrations observed over these sites still above the annual NO standard limit of 40 μg m and, therefore, more efficient measures are still needed. Primary NO emissions significantly influence NO concentrations at the three analysed sites. However, as no drastic changes are expected in the after-exhaust treatment technology that can reduce primary NO emissions to zero in the near future, only a substantial reduction in NO emissions will help to comply with the NO European air quality standards. Reduction of 78%, 56% and 16% on NO emissions in Barcelona, Madrid and Granada were estimated to be necessary to comply with the NO annual limit of 40 μg m.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.