Summary
Background
Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes.
Methods
For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813.
Findings
Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79).
Interpretation
In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws.
Funding
National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
The stabilizing capacity of the ligaments and articular surface in the ankle was determined under defined physiologic loading conditions. The concept of primary and secondary constraints was adapted to the ankle. With physiologic loading, the articular surface accounted for 30% and 100% of stability in rotation and version, respectively. That the articular surface was the sole source of inversion and eversion stability under the prescribed physiologic loading conditions has not been previously reported. The demonstration that the articular surface resists inversion displacement in the loaded ankle supports the conclusion of previous studies that rotation, rather than inversion, may account for a type of clinically symptomatic ankle instability. Further, ankle instability may occur during loading and unloading but not once the ankle is fully loaded. The results of our study confirm the importance of the anterior talofibular and calcaneofibular ligaments and suggest an important role for the deltoid ligament.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.