For patients undergoing craniotomy, it is desirable to have stable and easily controllable hemodynamics during intense surgical stimulation. However, rapid postoperative recovery is essential to assess neurologic function. Remifentanil, an ultra-short-acting mu-opioid receptor agonist, may be the ideal agent to confer the above characteristics. In this prospective randomized study, we compared the hemodynamic stability, recovery characteristics, and the dose of propofol required for maintaining anesthesia supplemented with an infusion of remifentanil, alfentanil, or fentanyl in 34 patients scheduled for supratentorial craniotomy. With routine monitors in place, anesthesia was induced with propofol (2-3 mg/kg), atracurium (0.5 mg/kg), and either remifentanil (1 microg/kg), alfentanil (10 microg/kg), or fentanyl (2 micro/kg). The lungs were ventilated with O2/air to mild hypocapnia. Anesthesia was maintained with infusions of propofol (50-100 microg/kg/min) and either remifentanil (0.2 microg/kg/min), alfentanil (20 microg/kg/h), or fentanyl (2 microg/kg/h). There were no significant differences among the groups in the dose of propofol maintenance required, heart rate, or mean arterial pressure. However, the time to eye opening (minutes) was significantly shorter in the remifentanil compared to the alfentanil group (6+/-3; 21+/-14; P = 0.0027) but not the fentanyl group (15+/-9). We conclude that remifentanil is an appropriate opioid to use in combination with propofol during anesthesia for supratentorial craniotomy.
Neurosurgery in the sitting position is used for resection of tumors located in the cerebellopontine angle, pineal region, other technically difficult tumors in the infratentorial region, as well as surgeries of the cervical spine. Since its inception, the use of this particular position has been contentious due its risk-benefit analysis. With improved microsurgical equipment and surgical and anesthetic techniques, as well as advanced monitoring techniques to assure patient safety, many centers are revisiting the sitting position for its potential benefits. Abstract Keywords ► patent foramen ovale ► sitting position ► venous air embolismTo ensure patient safety and a successful outcome, a thorough preoperative anesthetic evaluation to decide if the sitting position is suitable for the patient is essential. As in any neurosurgical case, all patients need to be evaluated preoperatively for physical and neurological status, as well J Neuroanaesthesiol Crit
ObjectiveThe use of open reduction and internal fixation (ORIF) for unstable pelvic injuries is associated with extensive blood loss, iatrogenic neurovascular injury, and infection. Moreover, the placement of sacroiliac (SI) screws is a blinded procedure, guided primarily by palpation and two-dimensional radiological screening, which demands expertise. The complex three-dimensional anatomy of SI joint and its proximity to neurovascular structure require a safe and precise technique. Computed tomography (CT)-guided SI joint stabilization allows an accurate intra-operative assessment of screw placement. This study demonstrated a technique of CT-guided closed reduction and screw fixation of the SI joint in unstable pelvic fractures.MethodsThis was a retrospective non-randomized cohort study conducted at a tertiary care hospital. Six patients with unstable pelvic fractures were operated; the anterior rim was stabilized first by ORIF with plate on the superior and anterior aspects of the pubic symphysis. Subsequently, the posterior stabilization was made percutaneously under CT guidance with a 7-mm cannulated cancellous screw.ResultsThe mean operative time was 48 min (35–90 min), the mean effective radiation dose was 9.32 (4.97–13.27), and the mean follow-up was 26 months (6–72 months). All patients had satisfactory healing, with near-anatomic reduction and no complications, except in one case where the plate broke at 61 months post surgery, but no intervention was required. The mean VAS score at the final follow-up was 1.8, and all patients returned to their original occupation without any limitations.ConclusionCT-guided SI joint stabilization offers many advantages, including safe and accurate screw placement, reduced operating time, decreased blood loss, early definitive fixation, immediate mobilization, and fewer infections and wound complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.