Introduction: Clinical laboratories offer several multipurpose tests, such as the erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), which are not intended to diagnose any specific disease but are used by clinicians in multiple fields. The results and laboratory interpretation (normal/abnormal) of these multipurpose tests are based on laboratory-reported normal thresholds, which vary across clinical laboratories. In 2018, the International Consensus Meeting on Musculoskeletal Infection (2018 ICM) provided a gold-standard definition to diagnose periprosthetic joint infection (PJI) which included many multipurpose laboratory tests, along with thresholds optimized to diagnose PJI. The discrepancy between laboratory-reported normal thresholds and 2018 ICM-recommended PJI-optimized test thresholds has never been studied. The purpose of this study was to assess the existing variation in laboratory-reported normal thresholds for tests commonly used to diagnose PJI and evaluate the potential diagnostic impact of using laboratory-reported normal thresholds instead of 2018 ICM-recommended PJI-optimized thresholds.Methods: Clinical laboratories (N=85) were surveyed to determine the laboratory-reported units of measure and normal thresholds for common multipurpose tests to diagnose PJI, including the ESR, CRP, D-dimer, synovial fluid white blood cells (SF-WBC), and polymorphonuclear cell percent (SF-PMN%). The variability of units of measure and normal thresholds for each test was then assessed among the 85 included clinical laboratories. A representative dataset from patients awaiting a revision arthroplasty was used to determine the clinical significance of the existing discrepancy between laboratory-reported normal test interpretations and 2018 ICM-recommended PJI-optimized test interpretations.Results: Two units of measure for the CRP and six units of measure for the D-dimer were observed, with only 59% of laboratories reporting the CRP in terms of mg/L and only 16% reporting the D-dimer in ng/ml, as needed to utilize the 2018 ICM definition of PJI. Across clinical laboratories surveyed, the mean laboratoryreported normal thresholds for the ESR (20 mm/h), CRP (7.69 mg/L), D-dimer (500 ng/mL), SF-WBC (5 cells/uL), and SF-PMN% (25%) were substantially lower than the 2018 ICM-recommended PJI-optimized thresholds of 30 mm/h, 10 mg/L, 860 ng/mL, 3,000 cells/uL, and 70%, respectively. Interpretation of test results from a representative PJI dataset using each laboratory's normal test thresholds yielded mean falsepositive rates of 14% (ESR), 18% (CRP), 42% (D-dimer), 93% (SF-WBC), and 36% (SF-PMN%) versus the ICMrecommended PJI-optimized thresholds.Conclusion: When reporting the results for multipurpose laboratory tests, such as the ESR, CRP, D-dimer, SF-WBC, and SF-PMN%, clinical laboratories utilize laboratory-reported units of measure and normal thresholds that are not intended to diagnose PJI, and therefore may not match the 2018 ICM recommendations. Our findings reveal that laboratory-reported normal thresh...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.