Overall, the amplitude-binning algorithm for 4DCT reconstruction reduced the severity of tumor distortion and image artifacts compared to the phase-binning algorithm. However, the full range of motion may not be characterized using amplitude-binning algorithms. Despite superior performance, amplitude binning can still be susceptible to motion artifacts caused by large variations in amplitude of respiratory waves.
By implementing MRI for EPB, we eliminate reliance on approximations of the eye and tumor shape and the assumption of idealized plaque placement. With MRI, one can perform preimplant as well as postimplant imaging, facilitating EPB treatment planning based on the actual patient-specific geometry and dose-delivery verification based on the imaged plaque position.
Purpose
Our purpose was to describe the risk of radiation-induced brachial plexopathy (RIBP) in patients with breast cancer who received comprehensive adjuvant radiation therapy (RT).
Methods and Materials
Records for 498 patients who received comprehensive adjuvant RT (treatment of any residual breast tissue, the underlying chest wall, and regional nodes) between 2004 and 2012 were retrospectively reviewed. All patients were treated with conventional 3 to 5 field technique (CRT) until 2008, after which intensity modulated RT (IMRT) was introduced. RIBP events were determined by reviewing follow-up documentation from oncologic care providers. Patients with RIBP were matched (1:2) with a control group of patients who received CRT and a group of patients who received IMRT. Dosimetric analyses were performed in these patients to determine whether there were differences in ipsilateral brachial plexus dose distribution between RIBP and control groups.
Results
Median study follow-up was 88 months for the overall cohort and 92 months for the IMRT cohort. RIBP occurred in 4 CRT patients (1.6%) and 1 IMRT patient (0.4%) (
P
= .20). All patients with RIBP in the CRT cohort received a posterior axillary boost. Maximum dose to the brachial plexus in RIBP, CRT control, and IMRT control patients had median values of 56.0 Gy (range, 49.7-65.1), 54.8 Gy (47.4-60.5), and 54.8 Gy (54.2-57.3), respectively.
Conclusions
RIBP remains a rare complication of comprehensive adjuvant breast radiation and no clear dosimetric predictors for RIBP were identified in this study. The IMRT technique does not appear to adversely affect the development of this late toxicity.
The purpose of this study was to describe the clinical implementation of a magnetic resonance image (MRI)‐based approach for adaptive intracavitary brachytherapy (ICBT) of cervix cancer patients. Patients were implanted with titanium tandem and colpostats. MR imaging was performed on a 1.5‐T Philips scanner using T2‐weighted (T2W), proton‐density weighted (PDW), and diffusion‐weighted (DW) imaging sequences. Apparent diffusion coefficient (ADC) maps were generated from the DW images. All images were fused. T2W images were used for the definition of organs at risk (OARs) and dose points. ADC maps in conjunction with T2W images were used for target delineation. PDW images were used for applicator definition. Forward treatment planning was performed using standard source distribution rules normalized to Point A. Point doses and dose‐volume parameters for the tumor and OARs were exported to an automated dose‐tracking application. Brachytherapy doses were adapted for tumor shrinkage and OAR variations during the course of therapy. The MRI‐based ICBT approach described here has been clinically implemented and is carried out for each brachytherapy fraction. Total procedure time from patient preparation to delivery of treatment is typically 2 hrs. Implementation of our technique for structure delineation, applicator definition, dose tracking, and adaptation is demonstrated using treated patient examples. Based on published recommendations and our clinical experience in the radiation treatment of cervix cancer patients, we have refined our standard approach to ICBT by 1) incorporating a multisequence MRI technique for improved visualization of the target, OARs, and applicator, and by 2) implementing dose adaptation by use of automated dose tracking tools.PACS numbers: 87.61.‐c, 87.53.Jw, 87.19.xj
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.