IntroductionThree-dimensional (3D) printing has become an affordable tool for assisting heart surgeons in the aorta endovascular field, both in surgical planning, education and training of residents and students. This technique permits the construction of physical prototypes from conventional medical images by converting the anatomical information into computer aided design (CAD) files.ObjectiveTo present the 3D printing feature on developing prototypes leading to improved aortic endovascular surgical planning, as well as transcatheter aortic valve implantation, and mainly enabling training of the surgical procedure to be performed on patient's specific condition.MethodsSix 3D printed real scale prototypes were built representing different aortic diseases, taken from real patients, to simulate the correction of the disease with endoprosthesis deployment.ResultsIn the hybrid room, the 3D prototypes were examined under fluoroscopy, making it possible to obtain images that clearly delimited the walls of the aorta and its details. The endovascular simulation was then able to be performed, by correctly positioning the endoprosthesis, followed by its deployment.ConclusionThe 3D printing allowed the construction of aortic diseases realistic prototypes, offering a 3D view from the two-dimensional image of computed tomography (CT) angiography, allowing better surgical planning and surgeon training in the specific case beforehand.
Introduction The coronavirus disease 2019 (COVID-19) pandemic brought an unprecedented lack of control of what was to come. The intent of this document is to provide a balance of how much was ceased to be done for patients with aortic disease, to assess the mortality of these patients, and to show what happened to those who became COVID-19 positive during their hospitalization. Methods From April 1st to July 31st 2020, the worst period of the pandemic in São Paulo, Brazil, the Institute’s aortic surgical patients operated on were evaluated and those were compared with patients operated during the same period in 2019. Results In 2019, 88 surgeries were performed; most of them were elective (66 [75%]), 10 were urgent, and 12 were emergency surgeries. In 2020, during the COVID-19 pandemic, we operated on only 31 patients, being 74.2% non-elective surgeries ( P <0,001). There was a higher mortality for patients operated on during the pandemic surge of COVID-19 ( P <0,001), but it was not specifically related to infected patients. Conclusion The COVID-19 pandemic had an impact on surgical volume and outcome of patients with aortic disease, although it did not directly increase mortality.
Rev Bras Cir Cardiovasc 2012;27(1):66-74
ObjectiveAortic valve replacement with Braile bovine pericardial prosthesis has been routinely done at the Heart Institute of the Universidade de São Paulo Medical School since 2006. The objective of this study is to analyze the results of Braile Biomédica® aortic bioprosthesis in patients with aortic valve disease.MethodsWe retrospectively evaluated 196 patients with aortic valve disease submitted to aortic valve replacement with Braile Biomédica® bovine pericardial prosthesis, between 2006 and 2010. Mean age was 59.41±16.34 years and 67.3% were male. Before surgery, 73.4% of patients were in NYHA functional class III or IV.ResultsHospital mortality was 8.16% (16 patients). Linearized rates of mortality, endocarditis, reintervention, and structural dysfunction were 1.065%, 0.91%, 0.68% and 0.075% patients/year, respectively. Actuarial survival was 90.59±2.56% in 88 months. Freedom from reintervention, endocarditis and structural dysfunction was respectively 91.38±2.79%, 89.84±2.92% and 98.57±0.72% in 88 months.ConclusionThe Braile Biomédica® pericardial aortic valve prosthesis demonstrated actuarial survival and durability similar to that described in the literature, but further follow up is required to assess the incidence of prosthetic valve endocarditis and structural dysfunction in the future.
We present a patient with an acute type A aortic dissection that involves the aortic root. The high mortality of patients with this condition is often associated with operations performed by surgeons with minimal experience dealing with aortic diseases. Therefore, less-experienced surgeons often opt for less complicated techniques like supracoronary ascending aortic replacement. However, according to the latest guidelines for the management of aortic diseases, the aortic root should be replaced when it is compromised by the dissection. The Bentall–de Bono technique treats the aortic root and demands less experience than valve-sparing aortic surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.