Cranioplasties are performed to protect the brain and correct cosmetic defects, but there is growing evidence that this procedure may result in neurological improvement. We prospectively studied cranioplasties performed at our hospital over a 5-year period. The National Institute of Health Stroke Scale and Barthel index were recorded prior to and within 72 h after the cranioplasty. A perfusion computed tomography (PCT) and transcranial Doppler sonography (TCDS) were performed prior to and 72 h after the surgery. For the PCT, regions irrigated by the anterior cerebral artery, the middle cerebral artery (MCA), the posterior cerebral artery, and the basal ganglia were selected, as well as the mean values for the hemisphere. The sonography was performed in the sitting and the supine position for the MCA and internal carotid. The velocities, pulsatility index, resistance index, and Lindegaard ratio (LR) were obtained, as well as a variation value for the LR (DLR = LR sitting -LR supine). Fifty-four patients were included in the study. Of these, 23 (42.6%) patients presented with objective improvement. The mean cerebral blood flow of the defective side (m-CBF-d) increased from 101.86 to 117.17 mL/100 g/min ( p = 0.064), and the m-CBF of the healthy side (m-CBF-h) increased from 128.14 to 145.73 mL/100 g/min ( p = 0.028). With regard to the TCDS, the DLR was greater on the defective side prior the surgery in those patients who showed improvement (1.295 vs. -0.714; p = 0.002). Cranioplasty resulted in clinical improvement in 40% of the patients, with an increase in the post-surgical CBF. The larger variations in the LR when the patient is moved from the sitting to the supine position might predict the clinical improvement.
We report on a 46-year-old woman who was involved in a road traffic accident. Neurological examination demonstrated paraplegia, while initial CT showed bilateral pneumothorax and hemothorax, rib fractures, a C2 vertebral body fracture with C2-C3 dislocation and active arterial bleeding at the sacral level. Given the fact that her neurological status did not particularly correspond with what we observed on CT scan, MRI was obtained due to the suspicion that a much more severe occult injury could be present. MRI showed a complete rupture of the posterior ligamentous complex along with the intervertebral disk and the posterior longitudinal ligament at T8-T9 level. The patient underwent minimally invasive posterior fixation with pedicle screws. Chance fractures of the thoracic spine are uncommon. To our knowledge, this is the first report of a pure soft-tissue Chance fracture located in the thoracic spine. Given that the initial CT showed no fracture evidence or vertebral malalignment, a high index of suspicion, based on the mechanism of injury, clinical examination and/or concomitant lesions, is necessary to identify such extremely unstable injury. Early recognition is crucial for appropriate therapy and to minimize the extent of neurological deficit.
Study Design. A prospective single center observational study.Objectives. The aim of this study was to examine the potential role of sonication in the diagnosis of low-grade infections and its association with pedicle screw (PS) loosening, and to describe risk factors and radiological findings associated with spinal implant infection. Summary of Background Data. Although PS loosening has mainly been attributed to mechanical overload, implant colonization and biofilm formation have recently been suggested. Culturing of sonication fluid implants is promising in the field of spine instrumentation infection, but little data are available. Methods. We prospectively included all patients who were subjected to implant removal. PS loosening was assessed with computed tomography (CT) scan. Different clinical and radiological parameters which could serve as indicators of implant infection were studied. Results. Thirty-eight patients were included in the study and 11 of them (29%) had a positive sonication result. Patients with spinal implant infection were associated with screw loosening (P ¼ 0.005). Particularly, those screws with a positive microbiological culture showed signs of screw loosening in the preoperative CT scan (P < 0.001). Our results also showed that radiological screw loosening at L1-L3 level, and loosened larger constructs were associated with screw microbial colonization. The most common isolated microorganisms were coagulasenegative staphylococci and Cutibacterium acnes. An implantbased multivariate analysis indicated that screw loosening, the absence of prophylactic cefazolin, ICU hospitalization, screw breakage, and L1-L3 spine level were independent risk factors for implant-associated infection. Our model exhibited a high predictive power with an area under the curve of 0.937. Conclusion. As clinical presentation of deep implant chronic infection is unspecific, consideration of these factors enables preoperative prediction and risk stratification of implant colonization, thus helping patient's management.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.