Chitin, the second most important natural polymer in the world, and its N-deacetylated derivative chitosan, have been identified as versatile biopolymers for a broad range of applications in medicine, agriculture and the food industry. Two of the main reasons for this are firstly the unique chemical, physicochemical and biological properties of chitin and chitosan, and secondly the unlimited supply of raw materials for their production. These polymers exhibit widely differing physicochemical properties depending on the chitin source and the conditions of chitosan production. The presence of reactive functional groups as well as the polysaccharide nature of these biopolymers enables them to undergo diverse chemical modifications. A complete chemical and physicochemical characterization of chitin, chitosan and their derivatives is not possible without using spectroscopic techniques. This review focuses on the application of spectroscopic methods for the structural analysis of these compounds.
We investigated the primary biodegradation of different N-imidazoles, imidazolium, pyridinium and 4-(dimethylamino)pyridinium compounds substituted with various alkyl side chains and their analogues containing functional groups principally based on OECD guideline 301 D. For the experiments we used two different types of inocula, a freeze-dried mix of bacteria and activated sludge microorganisms from a wastewater treatment plant. The aim of this study was to improve the knowledge base for the structural design of ionic liquids with respect to an increased biodegradability combined with a reduced (eco)toxicological hazard potential. We found a significant primary biodegradation for (eco)toxicologically unfavourable compounds carrying long alkyl side chains (C6 and C8). In contrast for (eco)toxicologically more recommendable imidazolium ionic liquids with short alkyl ((C6) and short functionalised side chains, no biological degradation could be found. The introduction of different functional groups into the side chain moiety thus offering a higher chemical reactivity did not lead to the expected improvement of the biological degradation. After an incubation period of 24 days for the 1-methyl-3-octylimidazolium cation we identified different biological transformation products carrying hydroxyl, carbonyl and carboxyl groups. Furthermore, shortened side chain moieties were identified indicating the degradation of the octyl side chain via b-oxidation. Moreover, we propose an electrochemical wastewater treatment as part of an alternative disposal strategy for non-biodegradable ionic liquids. We show for the first time that the 1-butyl-3-methylimidazolium cation was completely destroyed within four hours using an electrolysis double-cell (volume = 1.2 L) equipped with electrodes made of iridium oxide (anode), stainless steel (cathode), and a boron-doped diamond-coated bipolar electrode. The products formed electrochemically were easily accessible to biological degradation.
Motivated by the prevailing need for a sustainable development and taking the principles of Green Chemistry as a starting point, the present paper describes new and updated findings regarding a sustainable product design for ionic liquids. The focus is on environmental risk. Nevertheless, cytotoxicity testing and first indicative results from a genotoxicity study extend present knowledge also with regard to possible effects on humans. The structural variability of commercially available ionic liquids as well as the abundance of theoretically accessible ionic liquids is illustrated and the consequences for an integrated risk assessment accompanying the development process are discussed. The side chain effect on toxicity for imidazolium type ionic liquids was confounded by more complex biological testing. Also, an influence of an anion on cytotoxicity is shown for the first time. Testing of presumed metabolites of the imidazolium type cations showed a significantly lower biological activity in cytotoxicity studies than their parent compounds. The importance of a purity assessment for ionic liquids is pointed out and a collection of methods that is believed to be adequate is presented. In addition to risk analysis, the use of life cycle analysis for the multi-objective problem of designing ionic liquids is sketched and an eco-design scheme for ionic liquids is proposed. In conclusion, the paper illustrates the complex nature of the development processes ionic liquids are currently undergoing and provides guidance on which aspects have to be kept in mind.
The chemical and thermal stability of ionic liquids (ILs) makes them interesting for a large variety of applications in nearly all areas of the chemical industry. However, this stability is often reflected in their recalcitrance towards biodegradation, which comes with the risk of persistence when they are released into the environment. In this study we carried out a systematic investigation of the biodegradability of pyrrolidinium, morpholinium, piperidinium, imidazolium and pyridinium-based IL cations substituted with different alkyl or functionalised side chains and using halide counterions. We examined their primary degradability by specific analysis and/or their ultimate biodegradability using biochemical oxygen demand tests according to OECD guideline 301F. Biological transformation products were investigated using mass spectrometry. A comparison of the biodegradation potential of these ILs shows that for all five head groups, representatives can be found that are readily or inherently biodegradable, thus permitting the structural design of ILs with a reduced environmental hazard. † Electronic supplementary information (ESI) available. See
Abstract:The physicochemical nature of chitin and chitosan, which influences the biomedical activity of these compounds, is strongly related to the source of chitin and the conditions of the chitin/chitosan production process. Apart from widely described key factors such as weight-averaged molecular weight (M W ) and degree of N-acetylation (DA), other physicochemical parameters like polydispersity (M W /M N ), crystallinity or the pattern of acetylation (P A ) have to be taken into consideration. From the biological point of view, these parameters affect a very important factor-the solubility of chitin and chitosan in water and organic solvents. The physicochemical properties of chitosan solutions can be controlled by manipulating solution conditions (temperature, pH, ionic strength, concentration, solvent). The degree of substitution of the hydroxyl and the amino groups or the degree of quaternization of the amino groups also influence the mechanical and biological properties of chitosan samples. Finally, a considerable research effort has been directed towards developing safe and efficient chitin/chitosan-based products because many factors, like the size of nanoparticles, can determine the biomedical characteristics of medicinal products. The influence of these factors on the biomedical activity of chitin/chitosan-based products is presented in this report in more detail. OPEN ACCESSPolymers 2011, 3 1876
Liquid Organic Hydrogen Carrier (LOHC) systems offer a very attractive way to store and transport hydrogen, a technical feature that is highly desirable to link unsteady energy production from renewables with the vision of a sustainable, CO 2 -free, hydrogen-based energy system. LOHCs can be charged and discharged with considerable amounts of hydrogen in cyclic, catalytic hydrogenation and dehydrogenation processes. As their physico-chemical properties are very similar to diesel, today's infrastructure for liquid fuels can be used for their handling thus greatly facilitating the step-wise transition from today's fossil system to a CO 2 emission free energy supply for both, stationary and mobile applications. However, for a broader application of these liquids it is mandatory to study in addition to their technical performance also their potential impact on the environment and human health. This paper presents the first account on the toxicological profile of some potential LOHC structures. Moreover, it documents the importance of an early integration of hazard assessment in technology development and reveals for the specific case of LOHC structures the need for additional research in order to overcome some challenges in the hazard assessment for these liquids. Broader contextDue to increasing environmental awareness, many countries try to optimize their economies for a low-carbon growth turning towards renewable energy sources. Nevertheless, to fully exploit these sources fundamental change in our energy supplies is needed. Hydrogen is considered a main player in future energy systems, especially for mobile applications but its storage poses a technological challenge. Liquid Organic Hydrogen Carrier (LOHC) systems offer a very attractive way to store and transport hydrogen that links unsteady energy production from renewables with the vision of a sustainable, CO 2 -free, hydrogen-based energy system. LOHCs can be charged and discharged with considerable amounts of hydrogen in cyclic, catalytic hydrogenation and dehydrogenation processes. As their physico-chemical properties are very similar to those of diesel, today's infrastructure for liquid fuels can be used for their handling thus greatly facilitating the step-wise transition from today's fossil system to a CO 2 emission free energy supply for both, stationary and mobile applications. However, for a broader application of these liquids it is mandatory to study in addition to their technical performance also their potential impact on the environment and human health.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.