In the ultrasound medical imaging system, blurring which occurs after passing through ultrasound scanner system, represents Point Spread Function (PSF) that describes the response of the ultrasound imaging system to a point source distribution. So, de-blurring can be achieved by de-convolving the images with an estimated of PSF. However, it is hard to attain an accurate estimation of PSF due to the unknown properties of the tissues of the human body through the ultrasound signal propagates. In addition to, the complexity is very high in order to estimate point spread function and de-convolve the ultrasound image with estimated PSF for real-time implementation of ultrasound imaging. Therefore, conventional methods of ultrasound image restoration are based on a simple 1D PSF estimation [8] that axial direction only by restoring the performance improvement is not in the direction of Lateral. And, in case of 2D PSF estimation, PSF estimation and restoration of the high complexity is not being widely used. In this paper, we proposed new method for selection of the 2D PSF (estimated PSF of the average speed sound and depth) simultaneously with performing fast non-blind 2D de-convolution in the ultrasound imaging system. Our algorithm works on the beam-formed uncompressed radio-frequency data, with pre-measured and estimated 2D PSFs database from actual probe used. In the 2d PSF database, there are pre-measured and estimated 2D PSFs that classified the each different depth (about 5 different depths) and speed of sound (about 1450 or 1540m/s). Using a minimum variance and simple Weiner filter method, we present a novel way to select the optimal 2D PSF in pre-measured and estimated 2D PSFs database that acquired from the actual transducer being used. For de-convolution part with the chosen PSF, we focused on the low complexity issue. So, we are using the Weiner Filter and fast de-convolution technique using hyper-Laplacian priors [11], [12] which is several orders of magnitude faster than existing techniques that use hyper-Laplacian priors. Then, in order to prevent discontinuities between the differently restored each depth image regions, we use the piecewise linear interpolation on overlapping regions. We have tested our algorithm with vera-sonic system and commercial ultrasound scanner (Philips C4-2), in known speed of sound phantoms and unknown speeds in vivo scans. We have applied a non-blind de-convolution with 2D PSFs database for ultrasound imaging system. Using the real PSF from actual transducer being used, our algorithm produces a better restoration of ultrasound image than de-convolution by simulated PSF, and has low complexity for real-time ultrasound imaging. This method is robust and easy to implement. This method may be a realistic candidate for real-time implementation.
In the ultrasound imaging system, blurring which occurs after passing through ultrasound scanner system, represents point spread function (PSF) that describes the response of the ultrasound imaging system to a point source distribution. So, de-blurring can be achieved by de-convolving the ultrasound images with an estimated of corresponding PSF. However, it is hard to attain an accurate estimation of PSF due to the unknown properties of the tissues of the human body through the ultrasound signal propagates. In this paper, we present a new method for PSF estimation in the Fourier domain (FD) based on parametric minimum phase information, and simultaneously, it performs fast 2D de-convolution in the ultrasound imaging system. Although most of complex cepstrum methods [14], are obtained using complex 2D phase unwrapping [18] [19] in order to estimate the FD-phase information of PSF, our algorithm estimates the 2D PSF using 2D FD-phase information with the parametric weighting factor α and β. They affect the feature of PSF shapes. This makes the computations much simpler and the estimation more accurate. Our algorithm works on the beam-formed uncompressed radio-frequency data, with pre-measured and estimated 2D PSFs database from actual probe used. We have tested our algorithm with vera-sonic system and commercial ultrasound scanner (Philips C4-2), in known speed of sound phantoms and unknown speeds in vivo scans.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.