By providing three-dimensional visualization of tissues and instruments at high resolution, live volumetric optical coherence tomography (4D-OCT) has the potential to revolutionize ophthalmic surgery. However, the necessary imaging speed is accompanied by increased noise levels. A high data rate and the requirement for minimal latency impose major limitations for real-time noise reduction. In this work, we propose a low complexity neural network for denoising, directly incorporated into the image reconstruction pipeline of a microscope-integrated 4D-OCT prototype with an A-scan rate of 1.2 MHz. For this purpose, we trained a blind-spot network on unpaired OCT images using a self-supervised learning approach. With an optimized U-Net, only a few milliseconds of additional latency were introduced. Simultaneously, these architectural adaptations improved the numerical denoising performance compared to the basic setup, outperforming non-local filtering algorithms. Layers and edges of anatomical structures in B-scans were better preserved than with Gaussian filtering despite comparable processing time. By comparing scenes with and without denoising employed, we show that neural networks can be used to improve visual appearance of volumetric renderings in real time. Enhancing the rendering quality is an important step for the clinical acceptance and translation of 4D-OCT as an intra-surgical guidance tool.
Towards computer-assisted neurosurgery, scene understanding algorithms for microscope video data are required. Previous work utilizes optical flow to extract spatiotemporal context from neurosurgical video sequences. However, to select an appropriate optical flow method, we need to analyze which algorithm yields the highest accuracy for the neurosurgical domain. Currently, there are no benchmark datasets available for neurosurgery. In our work, we present an approach to generate synthetic data for optical flow evaluation on the neurosurgical domain. We simulate image sequences and thereby take into account domainspecific visual conditions such as surgical instrument motion. Then, we evaluate two optical flow algorithms, Farneback and PWC-Net, on our synthetic data. Qualitative and quantitative assessments confirm that our data can be used to evaluate optical flow for the neurosurgical domain. Future work will concentrate on extending the method by modeling additional effects in neurosurgery such as elastic background motion.
Previously introduced deep learning classifiers were able to support diabetic biomarker detection in OCTA en face images, but require pixel-by-pixel expert labeling, which is a labor-intensive and expensive process. We present a multiple-instance learning-based network, MIL-ResNet,14 that detects clinically relevant diabetic retinopathy biomarkers in a wide-angle (65°) OCTA dataset with high accuracy without annotation. We evaluated our proposed architecture against two well-established machine learning classifiers, ResNet14 and VGG16. The dataset we used for this study was acquired with a MHz A-scan rate swept source OCT device. We used a total of 352 en face images representing the retinal vasculature over an 18 mm x 18 mm field of view. MIL-ResNet14 outperformed the other two networks with an F-score of 0.95, a precision of 0.909 and an area under the curve of 0.973. In addition, we were able to demonstrate that MIL-ResNet14 paid special attention to relevant biomarkers such as ischemic areas and retinal vascular abnormalities by saliency overlay of gradient-weighted class activation maps on top of the en face images. Thus, OCTA could be used as a powerful diagnostic decision support tool for clinical ophthalmic screening in combination with our MIL approach.
Diabetic retinopathy (DR), a pathologic change of the human retinal vasculature, is the leading cause of blindness in working-age adults with diabetes mellitus. Optical coherence tomography angiography (OCTA), a functional extension of optical coherence tomography, has shown potential as a tool for early diagnosis of DR through its ability to visualize the retinal vasculature in all spatial dimensions. Previously introduced deep learning-based classifiers were able to support the detection of DR in OCTA images, but require expert labeling at the pixel level, a labor-intensive and expensive process. We present a multiple instance learning-based network, MIL-ResNet,14 that is capable of detecting biomarkers in an OCTA dataset with high accuracy, without the need for annotations other than the information whether a scan is from a diabetic patient or not. The dataset we used for this study was acquired with a diagnostic ultra-widefield swept-source OCT device with a MHz A-scan rate. We were able to show that our proposed method outperforms previous state-of-the-art networks for this classification task, ResNet14 and VGG16. In addition, our network pays special attention to clinically relevant biomarkers and is robust against adversarial attacks. Therefore, we believe that it could serve as a powerful diagnostic decision support tool for clinical ophthalmic screening.
Noise decreases image quality in optical coherence tomography (OCT) and can obscure important features in real-time visualizations. In this work, we show that a neural network can be applied to denoise volumetric OCT data for intra-surgical visualization in real-time. We adapt a self-supervised training approach, not requiring any paired data for training. Several optimizations and trade-offs in deployment are required, with which we achieved processing times of only few milliseconds. While still being limited by the real-time requirements, denoising in this scenario can enhance surface visibility, and therefore allow guidance for more precise intra-surgical maneuvers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.