Temporal bone abnormalities such as hypoplasia of the vestibular aqueduct or hypopneumatization of the mastoid have been described in Meniere's disease (MD). Jugular bulb abnormalities (JBA) are one of the most common temporal bone abnormalities. The aim of this study was to evaluate the frequency of JBA in MD. Radiological data obtained by temporal bone high-resolution computed tomography of 200 ears of 167 MD patients (MD group) and 218 ears of 109 patients with normal inner ear function (control group) were analyzed retrospectively. The frequencies of high jugular bulb (HJB), jugular bulb diverticulum (JBD), inner ear adjacent jugular bulb (IAJB) and jugular bulb related inner ear dehiscence (JBID) were evaluated and compared between MD group and control group. IAJB was differentiated into vestibular aqueduct adjacent jugular bulb (VAAJB), cochlear aqueduct adjacent jugular bulb and posterior semicircular canal adjacent jugular bulb. JBID was further analyzed by differentiating into jugular bulb related vestibular aqueduct dehiscence (JBVAD), jugular bulb related cochlear aqueduct dehiscence and jugular bulb related posterior semicircular canal dehiscence. The frequencies of HJB, JBD and IAJB were higher in MD group compared to control group (21, 13.3 %, p = 0.036; 8.5, 3.7 %, p = 0.037; 13.5, 4.6 %, p = 0.001). No differences between both groups were seen in JBID (4.0, 2.3 %, p = 0.315). Most IAJB and JBID were seen in VAAJB and JBVAD. There is a higher frequency of JBA in patients with MD than in patients without inner ear symptoms. Temporal bones of MD patients might be constituted anatomically different, carrying predisposing factors for the development of clinically apparent MD.
The influence of Eustachian tube (ET) dysfunction on the inner ear fluid pressure and thus on the inner ear function in Meniere's disease has been discussed controversially. So far, most of the studies examining ET function in inner ear disorders indirectly analyzed ET function by tympanometric methods. The present study directly studied ET function in inner ear disorders by sonotubometry. Healthy subjects and patients with Meniere's disease, sudden sensorineural hearing loss, cholesteatoma and chronic suppurative otitis media were examined by sonotubometry. Mean increase of sound pressure intensity (dB) and mean duration of sound pressure increase (s) were analyzed. Highest mean increase of sound pressure intensity was seen in healthy subjects when using >5 dB peaks (11.6 ± 0.7 dB) and >0 dB peaks (9.6 ± 0.6 dB). Comparative analysis including bilateral ears showed decreased ET function in patients with cholesteatoma (p = 0.002) and in patients with Meniere's disease (p = 0.003) when using >0 dB peaks. Examination of each specific ET opening maneuver showed impaired ET function in pathological ears of patients with cholesteatoma and with Meniere's disease, during yawning (p = 0.001; p < 0.001), dry swallowing (p = 0.010; p = 0.049), Toynbee maneuver (p = 0.033; p = 0.032) and drinking (p = 0.044; p = 0.027). Mild ET dysfunction is detected in patients with Meniere's disease by direct sonotubometric assessment of ET function.
Since inner ear hair cells are mechano-electric transducers the control of hydrostatic pressure in the inner ear is crucial. Most studies analyzing dynamics and regulation of inner ear hydrostatic pressure performed pressure measurements in the cochlea. The present study is the first one reporting about absolute hydrostatic pressure values in the labyrinth. Hydrostatic pressure of the endolymphatic system was recorded in all three semicircular canals. Mean pressure values were 4.06 cmH(2)O ± 0.61 in the posterior, 3.36 cmH(2)O ± 0.94 in the anterior and 3.85 cmH(2)O ± 1.38 in the lateral semicircular canal. Overall hydrostatic pressure in the vestibular organ was 3.76 cmH(2)O ± 0.36. Endolymphatic hydrostatic pressure in all three semicircular canals is the same (p = 0.310). With regard to known endolymphatic pressure values in the cochlea from past studies vestibular pressure values are comparable to cochlear values. Until now it is not known whether the reuniens duct and the Bast's valve which are the narrowest passages in the endolymphatic system are open or closed. Present data show that most likely the endolymphatic system is a functionally open entity.
Promontory VEMP testing was well tolerated by the patients. Mean latencies for p-c-VEMPs were 10.30 ± 2.23 ms (p1) and 17.86 ± 3.83 ms (n1). Mean latencies for p-o-VEMPs were 7.64 ± 1.24 ms (n1) and 11.2 ± 1.81 ms (p1). The stimulation threshold level was measured at 0.15 ± 0.07 mA for p-c-VEMPs and at 0.19 ± 0.11 mA for p-o-VEMPs. The discomfort level was found to be at 0.78 ± 0.29 mA for p-c-VEMPs and at 0.69 ± 0.25 mA for p-oVEMPs. Mean p1-n1 amplitude in p-c-VEMPs was 124.78 ± 56.55 µV and p-o-VEMPs showed a mean n1-p1 amplitude of 30.94 ± 18.98 µV.
The objective of the present study was to evaluate the cochlear aqueduct (CA) in Meniere's disease (MD) and to disclose radiological differences of CA between MD and non-MD patients by means of high-resolution computed tomography (HRCT) and high-resolution magnetic resonance imaging (HRMRI). Radiological data of 86 ears of MD patients which were separated into 52 ears of diseased side group (MD-D group) and 34 ears of contralateral non-affected side group of unilateral MD (MD-ND group), 27 ears of patients with sensorineural hearing loss (SNHL group) and 56 ears of patients with somatoform dizziness and normal hearing (control group) were analyzed retrospectively. The bony type of CA, the bony length of CA, and the bony width of CA medial orifice was measured in HRCT. The visibility of CA in HRMRI was scored. Fluid length in CA and fluid width in medial orifice were measured in HRMRI. Data were compared between MD-D, MD-ND, SNHL, and control group. There were no significant differences in the bony type of CA, bony length of CA, bony width of CA medial orifice, and fluid width of CA medial orifice between MD-D, MD-ND, SNHL and control group (p > 0.05). However, CA fluid length of MD-D (5.13 ± 1.88 mm) and of MD-ND group (5.44 ± 1.81 mm) was significantly shorter than fluid length of SNHL (6.90 ± 1.55 mm) (p < 0.001, p = 0.001) and of control group (7.43 ± 1.24 mm) (p < 0.001, p < 0.001). The ratio between CA fluid length and CA bony length was the smallest in MD-D group (0.403; p = 0.009). CA bony dimensions of affected ears of MD are normal, but CA fluid length is decreased.
Overall recurrences occurred in 35.0% of patients. Local, regional, and distant recurrences were found in 11.4%, 7.9%, and 15.7%. Hypopharyngeal carcinoma and advanced staged tumor showed highest recurrence rates. In all, 24.5% of all recurrences were treated successfully by salvage therapy. Resection of local, regional, and distant recurrences resulted in 3-year survival rates of 43.8%, 36.4%, and 4.5%. The outcome of secondary therapy worsened with advancing initial primary tumor stage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.