Maritime infrastructure is at high risk for corrosion-related damage over its service life. These assets are routinely subjected to harsh exposures and heavy usage that can degrade ordinary protective measures for reinforced concrete and steel elements. For owners and operators of ports and other maritime facilities, beginning with a strategic corrosion management plan is a proactive approach for maintenance and replacement needs. A corrosion management plan begins with understanding a few key items. First, identify what infrastructure elements are present and should be inventoried. Second, identify what construction materials and corrosion protection measures are already in place. Third, understand the nature and severity of environmental and usage-related exposures and impact on corrosion. Corrosion management plans have been adopted widely over the years by the oil, gas, and process industries for maintenance of various kinds of equipment, piping, and other needs. However, adoption of these techniques and procedures for civil and maritime infrastructure is still in its early stages. This paper presents the common types of techniques, methods, and documents available for inspecting maritime assets, evaluating exposures, and calculating service life of maritime infrastructure.
Chloride-induced corrosion of steel reinforcing bars is a major cause of deterioration in concrete bridge decks in northern climates. Corrosion-resistant epoxy-coated reinforcing (ECR) bars were introduced in the 1970s. In 1993, the West Virginia Department of Transportation (DOT) performed surveys of bridge decks treated with ECR and uncoated bars built in the mid-1970s. While deterioration was observed on uncoated bar decks, deterioration of decks built with ECR was found to be limited. The current investigation consisted of a questionnaire and review of the condition reports of the decks examined by the West Virginia DOT in 1993, followed by field condition surveys of six decks built with ECR to determine how the ECR was performing. The six bridge decks inspected were in good to excellent condition, with the exception of two spans of Bridge 2930, which were reinforced with uncoated black bars. The decks with ECR exhibited less than 0.15% corrosion-induced deterioration. Any deterioration observed on ECR decks was concentrated at cracks or construction joints. All actively corroding ECR bars had an average coating thickness less than 7 mil (0.007 in.), the current minimum specified thickness. Decks reinforced with uncoated black bars included in the 1993 study had an initial service life of 18 to 21 years, and an overlay was applied to all of these decks to address corrosion-related damage. The decks constructed with ECR are now 33 to 35 years old, and none have required rehabilitation to address corrosion-related deterioration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.