Frailty is characterized by a loss of functionality and is expected to affect 9.9% of people aged 65 and over. Here, current frailty classification is compared with a collection of selected kinematic parameters. A total of 718 elderly subjects (319 males and 399 females; age: 75.4 ± 6.1 years), volunteered to participate in this study and were classified according to Fried's criteria. Both the 30-s chair stand test (CST) and the 3-m walking test were performed and a set of kinematic parameters were obtained from a single inertial unit. A decision tree analysis was used to: 1) identify the most relevant frailty-related parameters and 2) compare validity of this classification. We found that a selected set of parameters from the 30-s CST (i.e., range of movement, acceleration, and power) were better at identifying frailty status than both the actual outcome of the test (i.e., cycles' number) and the normally used criteria (i.e., gait speed). For the pre-frail status, AUC improves from 0.531 using the actual test outcome and 0.516 with gait speed to 0.938 with the kinematic parameters criteria. In practice, this could improve the presyndrome identification and perform the appropriate actions to postpone the progression into the frail status.
Progress in micro-electromechanical systems has turned inertial sensor units (IUs) into a suitable tool for vertical jumping evaluation. In total, 9 men and 8 women were recruited for this study. Three types of vertical jumping tests were evaluated in order to determine if the data provided by an IU placed at the lumbar spine could reliably assess jumping biomechanics and to examine the validity of the IU compared with force plate platform recordings. Robust correlation levels of the IU-based jumping biomechanical evaluation with respect to the force plate across the entire analysed jumping battery were found. In this sense, significant and extremely large correlations were found when raw data of both IU and force plate-derived normalised force-time curves were compared. Furthermore, significant and mainly moderate correlation levels were also found between both instruments when isolated resultant forces' peak values of predefined jumping phases of each manoeuvre were analysed. However, Bland and Altman graphical representation demonstrated a systematic error in the distribution of the data points within the mean ±1.96 SD intervals. Using IUs, several biomechanical variables such as the resultant force-time curve patterns of the three different vertical jumps analysed were reliably measured.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.