Background Until recently, investigations of the normal patterns of motility of the healthy human colon have been limited by the resolution of in vivo recording techniques. Methods We have used a new, high-resolution fiber-optic manometry system (72 sensors at 1-cm intervals) to record motor activity from colon in 10 healthy human subjects. Key Results In the fasted colon, on the basis of rate and extent of propagation, four types of propagating motor pattern could be identified: (i) cyclic motor patterns (at 2–6/min); (ii) short single motor patterns; (iii) long single motor patterns; and (iv) occasional retrograde, slow motor patterns. For the most part, the cyclic and short single motor patterns propagated in a retrograde direction. Following a 700 kCal meal, a fifth motor pattern appeared; high-amplitude propagating sequences (HAPS) and there was large increase in retrograde cyclic motor patterns (5.6±5.4/2 h vs 34.7±19.8/2 h; p < 0.001). The duration and amplitude of individual pressure events were significantly correlated. Discriminant and multivariate analysis of duration, gradient, and amplitude of the pressure events that made up propagating motor patterns distinguished clearly two types of pressure events: those belonging to HAPS and those belonging to all other propagating motor patterns. Conclusions & Inferences This work provides the first comprehensive description of colonic motor patterns recorded by high-resolution manometry and demonstrates an abundance of retrograde propagating motor patterns. The propagating motor patterns appear to be generated by two independent sources, potentially indicating their neurogenic or myogenic origin.
In patients with STC a meal fails to induce the normal increase in the distal colonic cyclic propagating motor patterns. We propose that these data may indicate that the normal extrinsic parasympathetic inputs to the colon are attenuated in these patients.
Excitatory and inhibitory enteric neural input to intestinal muscle acting on ongoing myogenic activity determines the rich repertoire of motor patterns involved in digestive function. The enteric neural activity cannot yet be established during movement of intact intestine in vivo or in vitro. We propose the hypothesis that is possible to deduce indirectly, but reliably, the state of activation of the enteric neural input to the muscle from measurements of the mechanical state of the intestinal muscle. The fundamental biomechanical model on which our hypothesis is based is the “three-element model” proposed by Hill. Our strategy is based on simultaneous video recording of changes in diameters and intraluminal pressure with a fiber-optic manometry in isolated segments of rabbit colon. We created a composite spatiotemporal map (DPMap) from diameter (DMap) and pressure changes (PMaps). In this composite map rhythmic myogenic motor patterns can readily be distinguished from the distension induced neural peristaltic contractions. Plotting the diameter changes against corresponding pressure changes at each location of the segment, generates “orbits” that represent the state of the muscle according to its ability to contract or relax actively or undergoing passive changes. With a software developed in MatLab, we identified twelve possible discrete mechanical states and plotted them showing where the intestine actively contracted and relaxed isometrically, auxotonically or isotonically, as well as where passive changes occurred or was quiescent. Clustering all discrete active contractions and relaxations states generated for the first time a spatio-temporal map of where enteric excitatory and inhibitory neural input to the muscle occurs during physiological movements. Recording internal diameter by an impedance probe proved equivalent to measuring external diameter, making possible to further develop similar strategy in vivo and humans.
Distal gut motility becomes markedly hyperactive with colonic surgery, dominated by cyclic motor patterns. This hyperactivity likely represents a novel pathophysiological aspect of the surgical stress response. Hyperactive motility may contribute to gut dysfunction after surgery, potentially offering a new therapeutic target to enhance recovery.
Colonic cyclic motor patterns (CMPs) have been hypothesized to act as a brake to limit rectal filling. However, the spatiotemporal profile of CMPs, including anatomic origins and distributions, remains unclear. This study characterized colonic CMPs using high-resolution (HR) manometry (72 sensors, 1-cm resolution) and their relationship with proximal antegrade propagating events. Nine healthy volunteers were recruited. Recordings were performed over 4 h, with a 700-kcal meal given after 2 h. Propagating events were visually identified and analyzed by pattern, origin, amplitude, extent of propagation, velocity, and duration. Manometric data were normalized using anatomic landmarks identified on abdominal radiographs. These were mapped over a three-dimensional anatomic model. CMPs comprised a majority of detected propagating events. Most occurred postprandially and were retrograde propagating events (84.9 ± 26.0 retrograde vs. 14.3 ± 11.8 antegrade events/2 h, = 0.004). The dominant sites of initiation for retrograde CMPs were in the rectosigmoid region, with patterns proximally propagating by a mean distance of 12.4 ± 0.3 cm. There were significant differences in the characteristics of CMPs depending on the direction of travel and site of initiation. Association analysis showed that proximal antegrade propagating events occurred independently of CMPs. This study accurately characterized CMPs with anatomic correlation. CMPs were unlikely to be triggered by proximal antegrade propagating events in our study context. However, the distal origin and prominence of retrograde CMPs could still act as a mechanism to limit rectal filling and support the theory of a "rectosigmoid brake." Retrograde cyclic motor patterns (CMPs) are the dominant motor patterns in a healthy prepared human colon. The major sites of initiation are in the rectosigmoid region, with retrograde propagation, supporting the idea of a "rectosigmoid brake." A significant increase in the number of CMPs is seen after a meal. In our study context, the majority of CMPs occurred independent of proximal propagating events, suggesting that CMPs are primarily controlled by external innervation.
SNS modulates colonic motility in patients with faecal urge incontinence. These data suggest that SNS may improve continence and urgency through alteration of colonic motility, particularly by increasing retrograde PSs in the left colon.
The design of a fibre Bragg grating based manometry catheter for in-vivo diagnostics in the human colon is presented. The design is based on a device initially developed for use in the oesophagus, but in this instance, longer sensing lengths and increased flexibility were required to facilitate colonoscopic placement of the device and to allow access to the convoluted regions of this complex organ. The catheter design adopted allows the number of sensing regions to be increased to cover extended lengths of the colon whilst maintaining high flexibility and the close axial spacing necessary to accurately record pertinent features of peristalsis. Catheters with 72 sensing regions with an axial spacing of 1 cm have been assembled and used in-vivo to record peristaltic contractions in the human colon over a 24hr period. The close axial spacing of the pressure sensors has, for the first time, identified the complex nature of propagating sequences in both antegrade (towards the anus) and retrograde (away from the anus) directions in the colon. The potential to miss propagating sequences at wider sensor spacings is discussed and the resultant need for close axial spacing of sensors is proposed.
Propulsive contractions of circular muscle are largely responsible for the movements of content along the digestive tract. Mechanical and electrophysiological recordings of isolated colonic circular muscle have demonstrated that localized distension activates ascending and descending interneuronal pathways, evoking contraction orally and relaxation anally. These polarized enteric reflex pathways can theoretically be sequentially activated by the mechanical stimulation of the advancing contents. Here, we test the hypothesis that initiation and propagation of peristaltic contractions involves a neuromechanical loop; that is an initial gut distension activates local and oral reflex contraction and anal reflex relaxation, the subsequent movement of content then acts as new mechanical stimulus triggering sequentially reflex contractions/relaxations at each point of the gut resulting in a propulsive peristaltic contraction. In fluid filled isolated rabbit distal colon, we combined spatiotemporal mapping of gut diameter and intraluminal pressure with a new analytical method, allowing us to identify when and where active (neurally-driven) contraction or relaxation occurs. Our data indicate that gut dilation is associated with propagating peristaltic contractions, and that the associated level of dilation is greater than that preceding non-propagating contractions (2.7 ± 1.4 mm vs. 1.6 ± 1.2 mm; P < 0.0001). These propagating contractions lead to the formation of boluses that are propelled by oral active neurally driven contractions. The propelled boluses also activate neurally driven anal relaxations, in a diameter dependent manner. These data support the hypothesis that neural peristalsis is the consequence of the activation of a functional loop involving mechanical dilation which activates polarized enteric circuits. These produce propulsion of the bolus which activates further anally, polarized enteric circuits by distension, thus closing the neuromechanical loop.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.