Spatial distortion results in image deformation that can degrade accurate targeting and dose calculations in MRI-guided adaptive radiotherapy. The authors present a comprehensive assessment of a 0.35 T MRI-guided radiotherapy system’s spatial distortion using two commercially-available phantoms with regularly spaced markers. Images of the spatial integrity phantoms were acquired using five clinical protocols on the MRI-guided radiotherapy machine with the radiotherapy gantry positioned at various angles. Software was developed to identify and localize all phantom markers using a template matching approach. Rotational and translational corrections were implemented to account for imperfect phantom alignment. Measurements were made to assess uncertainties arising from susceptibility artifacts, image noise, and phantom construction accuracy. For a clinical 3D imaging protocol with a 1.5 mm reconstructed slice thickness, 100% of spheres within a 50 mm radius of isocenter had a 3D deviation of 1 mm or less. Of the spheres within 100 mm of isocenter, 99.9% had a 3D deviation less than 1 mm. 94.8% and 100% of the spheres within 175 mm were found to be within 1 mm and 2 mm of the expected positions in 3D respectively. Maximum 3D distortions within 50 mm, 100 mm and 175 mm of isocenter were 0.76 mm, 1.15 mm and 1.88 mm respectively. Distortions present in images acquired using the real-time imaging sequence were less than 1 mm for 98.1% and 95.0% of the cylinders within 50 mm and 100 mm of isocenter. The corresponding maximum distortion in these regions was 1.10 mm and 1.67 mm. These results may be used to inform appropriate planning target volume (PTV) margins for 0.35 T MRI-guided radiotherapy. Observed levels of spatial distortion should be explicitly considered when using PTV margins of 3 mm or less or in the case of targets displaced from isocenter by more than 50 mm.
PurposeMagnetic resonance image (MRI) guided radiotherapy enables gating directly on the target position. We present an evaluation of an MRI‐guided radiotherapy system's gating performance using an MRI‐compatible respiratory motion phantom and radiochromic film. Our evaluation is geared toward validation of our institution's clinical gating protocol which involves planning to a target volume formed by expanding 5 mm about the gross tumor volume (GTV) and gating based on a 3 mm window about the GTV.MethodsThe motion phantom consisted of a target rod containing high‐contrast target inserts which moved in the superior‐inferior direction inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical planning target volume, and delivered to the phantom at rest and in motion with and without gating. Both sinusoidal trajectories and tumor trajectories measured during MRI‐guided treatments were used. Similarity of the gated dose distribution to the planned, motion‐frozen, distribution was quantified using the gamma technique.ResultsWithout gating, gamma pass rates using 4%/3 mm criteria were 22–59% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% target allowed outside the gating boundary, the gamma pass rate was 97.8% with 3%/3 mm gamma criteria. Using a 3 mm window and 10% allowed excursion, all of the patient tumor motion trajectories at actual speed resulting in at least 95% gamma pass rate at 4%/3 mm.ConclusionsOur results suggest that the device can be used to compensate respiratory motion using a 3 mm gating margin and 10% allowed excursion results in conjunction with repeated breath holds. Full clinical validation requires a comprehensive evaluation of tracking performance in actual patient images, outside the scope of this study.
This work demonstrates the concept of model-interpolated gating for MRI-guided radiation therapy. The technique was found to be potentially sufficiently accurate for clinical use. Further development is needed to accommodate out-of-plane motion and the use of an internal MR-based respiratory surrogate.
Purpose To develop and evaluate a novel motion prediction method for magnetic resonance image (MRI)‐guided radiotherapy applications. This method, which we deem “image regression,” predicts future tissue motion based on a weighted combination of previously observed motion states. Motion predictions are derived from a sliding window of recent motion states which are defined by a temporal sequence of images. A key advantage of this method compared to other motion prediction methods is that its computational complexity scales weekly with the number of spatial points predicted. Applications of gating latency reduction and improvement in deformable registration‐based target tracking are demonstrated. Methods The image regression (IR) motion prediction method was developed and evaluated using 26.9 h of real‐time imaging acquired from eight healthy volunteers and 13 patients using a 0.35 T MRI‐guided radiotherapy system. Motion predictions were performed 0.25–0.33 s into the future using a weighted sum of previously observed motion states with image similarity‐derived weights. The set of previously observed motion states were continuously updated to incorporate the changes in breathing patterns. The accuracy of the predicted radiotherapy gating decision, beam‐on positive predictive value (PPV), and predicted vs ground‐truth target centroid position errors are reported. The IR technique was compared against no prediction, linear extrapolation, and an established autoregressive linear prediction algorithm. The usage of IR to initialize the deformable registration and enhance the target tracking was demonstrated in the healthy volunteer studies. Deformable registration with IR initialization was compared to the initialization performed by current clinical software: no initialization, previous image registration initialization and linear motion extrapolation initialization. Results The average IR‐predicted radiation beam gating decision accuracy was 95.8%, with a PPV of 95.7%, and median and 95th percentile centroid position errors of 0.63 and 2.08 mm, respectively. Compared to the autoregressive linear prediction method, gating accuracy was 1.15% greater, PPV was 1.61% greater, and median and 95th percentile centroid distances were 0.21 and 0.23 mm smaller. The IR‐initialized registration on average converged within 0.50 mm of the ground‐truth position in fewer than 10 iterations whereas the next best initialization method required more than 25 iterations. Conclusions Image regression motion prediction has the potential to reduce the gating latencies and improve the speed and accuracy of deformable registration‐based target tracking in MRI‐guided radiotherapy.
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Purpose On‐board magnetic resonance imaging (MRI) greatly enhances real‐time target tracking capability during radiotherapy treatments. However, multislice and volumetric MRI techniques are frame rate limited and introduce unacceptable latency between the target moving out of position and the beam being turned off. We present a technique to estimate continuous volumetric tissue motion using motion models built from a repeated acquisition of a stack of MR slices. Applications including multislice target visualization and out‐of‐slice motion estimation during MRI‐guided radiotherapy are demonstrated. Methods Eight healthy volunteer studies were performed using a 0.35 T MRI‐guided radiotherapy system. Images were acquired at three frames per second in an interleaved fashion across ten adjacent sagittal slice positions covering 4.5 cm using a balanced steady‐state–free precession sequence. A previously published five‐dimensional (5D) linear motion model used for MRI‐guided radiotherapy gating was extended to include multiple slices. This model utilizes an external respiratory bellows signal recorded during imaging to simultaneously estimate motion across all imaged slices. For comparison to an image‐based approach, the manifold learning technique local linear embedding (LLE) was used to derive a respiratory surrogate for motion modeling. Manifolds for every slice were aligned during LLE in a group‐wise fashion, enabling motion estimation outside the current imaged slice using a motion model, a process which we denote as mSGA. Additionally, a method is developed to evaluate out‐of‐slice motion estimates. The multislice motion model was evaluated in a single slice with each newly acquired image using a leave‐one‐out approach. Model‐generated gating decision accuracy and beam‐on positive predictive value (PPV) are reported along with the median and 95th percentile distance between model and ground truth target centroids. Results The average model gating decision accuracy and PPV across all volunteer studies was 93.7% and 92.8% using the 5D model, and 96.8% and 96.1% using the mSGA model, respectively. The median and 95th percentile distance between model and ground truth target centroids was 0.91 and 2.90 mm, respectively, using the 5D model and 0.58 and 1.49 mm using the mSGA model, averaged over all eight subjects. The mSGA motion model provided a statistically significant improvement across all evaluation metrics compared to the external surrogate‐based 5D model. Conclusion The proposed techniques for out‐of‐slice target motion estimation demonstrated accuracy likely sufficient for clinical use. Results indicate the mSGA model may provide higher accuracy, however, the external surrogate‐based model allows for unbiased in vivo accuracy evaluation.
Purpose: Motion prediction can compensate for latency in image-guided radiotherapy and has been an active area of research. However, motion predictions are subject to error and variations. We have developed and evaluated a novel motion prediction confidence estimation framework to improve the efficacy and robustness of prediction-based radiotherapy gating decision-making. The specific scenario of adaptive gating in magnetic resonance imaging (MRI)-guided radiotherapy is studied as an example, but the method generalizes to other modalities and motion management setups. Methods: The proposed prediction confidence estimator is based on a generic training/testing paradigm and consists of a weighted combination of three components: the prediction model's goodness of fit, variation in the prediction using a leave-one-out process and the velocity of the tracked target. Roughly, these terms quantify respectively the consistency between prediction and the training data, the robustness of model inference, and the stability due to target speed. The weight parameters and the action level in triggering beam-off decision are optimized. The method is assessed and validated in 8 healthy volunteer and 13 patient studies using a 0.35T MRI-guided radiotherapy system predicting 0.25-0.33 s ahead. The effect of the action level on the predicted gating decision accuracy, beam-on positive predictive value (PPV) and median distance between the predicted and ground-truth target centroids were evaluated. Statistical significance was evaluated using a paired t-test. The tradeoff between these performance metrics and gating duty cycle was assessed. Results: Use of the confidence estimator threshold increased gating accuracy by up to 2.42%, increased PPV by up to 3.00%, and reduced the median centroid distance up to 0.28 mm. The confidence estimator threshold on average increased gating accuracy to 96.5% (P = 2.08 9 10 À4 ), increased PPV to 96.7% (P = 1.46 9 10 À5 ), reduced the median centroid distance to 0.54 mm (P = 1.71 9 10 À5 ) at the cost of reducing the gating duty cycle by 14.3% to 48.5%. Hyperparameter tuning revealed that contrary to intuition, the velocity term offered only minimal performance improvement in some cases but also introduced potential stability issues. The combination of goodness of fit and leave-one-out prediction variation provided the most effective confidence estimator, yielding universally better performance in gating decisions. Conclusion: Confidence estimation utilizing prediction model fitness criterion and validation principles can complement prediction methods to guide MRI-guided radiotherapy gating. Results from both volunteer and patient studies showed improved gating quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.