Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.
BackgroundPyronaridine–artesunate is a novel artemisinin-based combination therapy. The efficacy and safety of pyronaridine–artesunate were compared with artemether–lumefantrine for the treatment of uncomplicated Plasmodium falciparum malaria in children.MethodsThis phase III open-label randomized controlled non-inferiority trial was conducted in Western Kenya. Children aged 6 months to ≤ 12 years with a bodyweight > 5 kg and microscopically confirmed P. falciparum malaria were randomly assigned in a 1:1 ratio to orally receive pyronaridine–artesunate or artemether–lumefantrine, dosed according to bodyweight, for 3 days.ResultsOf 197 participants, 101 received pyronaridine–artesunate and 96 received artemether–lumefantrine. The day-28 adequate clinical and parasitological response in the per-protocol population, PCR-corrected for reinfections, was 98.9% (93/94, 95% CI 94.2–99.8) for pyronaridine–artesunate and 96.4% (81/84, 95% CI 90.0–98.8) for artemether–lumefantrine. Pyronaridine–artesunate was found to be non-inferior to artemether–lumefantrine: the treatment difference was 2.5% (95% CI − 2.8 to 9.0). Adverse events occurred in 41.6% (42/101) and 34.4% (33/96) of patients in the pyronaridine–artesunate group and the artemether–lumefantrine group, respectively. No participants were found to have alanine or aspartate aminotransferase levels > 3 times the upper limit of normal.ConclusionsPyronaridine–artesunate was well tolerated, efficacious and non-inferior to artemether–lumefantrine for the treatment of uncomplicated P. falciparum malaria in Kenyan children. Results are in line with previous reports and inclusion of pyronaridine–artesunate in paediatric malaria treatment programmes should be considered.This study is registered at clinicaltrials.gov under NCT02411994. Registration date: 8 April 2015. https://clinicaltrials.gov/ct2/show/NCT02411994?term=pyronaridine–artesunate&cond=Malaria&cntry=KE&rank=1Electronic supplementary materialThe online version of this article (10.1186/s12936-018-2340-3) contains supplementary material, which is available to authorized users.
BackgroundIron-deficient erythropoiesis results in excess formation of zinc protoporphyrin (ZPP), which can be measured instantly and at low assay cost using portable haematofluorometers. ZPP is used as a screening marker of iron deficiency in individual pregnant women and children, but also to assess population iron status in combination with haemoglobin concentration. We examined associations between ZPP and disorders that are common in Africa. In addition, we assessed the diagnostic utility of ZPP (measured in whole blood and erythrocytes), alone or in combination with haemoglobin concentration, in detecting iron deficiency (plasma ferritin concentration <15 μg/L).MethodsSingle blood samples were collected from a population sample of 470 rural Kenyan women with singleton pregnancies, gestational age 13 to 23 weeks, and haemoglobin concentration ≥90 g/L. We used linear regression analysis to assess associations between ZPP and iron markers (including anaemia), factors known or suspected to be associated with iron status, inflammation markers (plasma concentrations of C-reactive protein and α1-acid glycoprotein), infections (Plasmodium infection, HIV infection), and other disorders (α+-thalassaemia, plasma concentrations of total bilirubin, and lactate dehydrogenase). Subsequently, in those without inflammation, Plasmodium infection, or HIV infection, we used logistic discriminant analysis and examined receiver operating characteristics curves with corresponding area-under-the-curve to assess diagnostic performance of ZPP, alone and in combination with haemoglobin concentration.ResultsIndividually, whole blood ZPP, erythrocyte ZPP, and erythrocyte protoporphyrin had limited ability to discriminate between women with and without iron deficiency. Combining each of these markers with haemoglobin concentration had no additional diagnostic value. Conventional cut off points for whole blood ZPP (>70 μmol/mol haem) resulted in gross overestimates of the prevalence of iron deficiency.ConclusionsErythrocyte ZPP has limited value to rule out iron deficiency when used for screening in conditions with a low prevalence (e.g., 10%). ZPP is of unreliable diagnostic utility when discriminating between pregnant women with and without iron deficiency. Based on these findings, guidelines on the use of ZPP to assess iron status in individuals or populations of pregnant women need review.Trial registrationNCT01308112 (2 March 2011).
Since its introduction, contrast-enhanced ultrasonography (CEUS) has significantly extended the value of ultrasonography (US). CEUS can be used to more accurately determine pancreatic lesions compared to conventional US or to characterize lesions already detectable by US. Thus, CEUS can aid in the differential diagnosis of pancreatic tumors. Using US contrast media, it is possible to visually detect microvessels in the majority of pancreatic ductal adenocarcinomas. Thus, the use of quantitatively evaluated transabdominal CEUS can help in the differentiation of patients with mass-forming pancreatitis from patients with pancreatic adenocarcinomas. In neuroendocrine pancreatic tumors, different enhancement patterns can be observed in relation to the tumor mass: larger ones show a rapid early enhancement sometimes combined with necrotic central structures, and smaller ones disclose a capillary-blush enhancement. Pseudocysts, the most widespread cystic lesions of the pancreas, are not vascularized. They do not show any signal in CEUS and remain entirely anechoic in all phases, while true cystic pancreatic tumors usually have vascularized septa and parietal nodules. In summary, CEUS is effective for differentiating solid pancreatic tumors in most cases. CEUS is safe and cost effective and can better discriminate solid from cystic pancreatic lesions, thereby directing further imaging modalities.
Decreasing malaria transmission warrants the search for highly sensitive point-of-care diagnostics, especially in resource-limited settings. The direct-on-blood PCR nucleic acid lateral flow immunoassay (db-PCR-NALFIA) is a simplified PCR-based technique with a lateral flow readout that does not require sample preparation. Two duplex db-PCR-NALFIAs were developed: a pan-Plasmodium/Plasmodium falciparum (pan/P. falciparum) and a pan-Plasmodium/Plasmodium vivax (pan/P. vivax) assay. Confirmed positive samples (n = 61) and negative controls (n = 40) were used for laboratory validations. A prospective field evaluation of the pan/P. falciparum assay was performed in Kenya (n = 300). In the laboratory validation, sensitivity and specificity of the pan/P. falciparum assay were 100% (95% CI, 94.1%-100%) and 100% (95% CI, 91.2%-100%), respectively. Sensitivity and specificity of the pan/P. vivax assay were 100% (95% CI, 94.1%-100%) and 97.5% (95% CI, 86.8%-99.9%), respectively. In Kenya, sensitivity of the pan/P. falciparum db-PCR-NALFIA was 97.2% (95% CI, 93.0%-99.2%) and specificity was 74.2% (95% CI, 67.0%-81.0%) compared with reference standard microscopy. When using real-time quantitative PCR as a reference standard, sensitivity was 84.5% (95% CI, 78.7%-89.3%) and specificity was 85.4% (95% CI, 77.1%-91.6%). Db-PCR-NALFIA is a sensitive, specific, and easy method for the detection and species differentiation of Plasmodium. This test is especially of interest for malaria control or elimination programs in low-transmission settings that require accurate detection of low parasite densities.
Artemisinin resistance is rapidly rising in Southeast Asia and may spread to African countries, where efficacy estimates are currently still excellent. Extensive monitoring of parasite clearance dynamics after treatment is needed to determine whether responsiveness to artemisinin-based combination therapies (ACT) is changing in Africa. In this study, Kenyan children with uncomplicated malaria were randomly assigned to pyronaridine-artesunate (PA) or artemether-lumefantrine (AL) treatment. Parasite clearance was evaluated over 7 days following the start of treatment by quantitative polymerase chain reaction (qPCR) and direct-on-blood PCR nucleic acid lateral flow immunoassay (db-PCR-NALFIA), a simplified molecular malaria diagnostic. Residual parasitemia at day 7 was detected by qPCR in 37.1% (26/70) of AL-treated children and in 46.1% (35/76) of PA-treated participants ( = 0.275). Direct-on-blood PCR nucleic acid lateral flow immunoassay detected residual parasites at day 7 in 33.3% (23/69) and 30.3% (23/76) of AL and PA-treated participants, respectively ( = 0.692). qPCR-determined parasitemia at day 7 was associated with increased prevalence and density of gametocytes at baseline ( = 0.014 and = 0.003, for prevalence and density, respectively) and during follow-up ( = 0.007 and = 0.011, respectively, at day 7). A positive db-PCR-NALFIA outcome at day 7 was associated with treatment failure (odds ratio [OR]: 3.410, 95% confidence interval [CI]: 1.513-7.689, = 0.003), but this association was not found for qPCR (OR: 0.701, 95% CI: 0.312-1.578, = 0.391). Both qPCR and db-PCR-NALFIA detected substantial residual submicroscopic parasitemia after microscopically successful PA and AL treatment and can be useful tools to monitor parasite clearance. To predict treatment outcome, db-PCR-NALFIA may be more suitable than qPCR.
BackgroundIron-deficient erythropoiesis results in excess formation of zinc protoporphyrin (ZPP), which can be measured instantly and at low assay cost using portable haematofluorometers. ZPP is used as a screening marker of iron deficiency in individual pregnant women and children, but also to assess population iron status in combination with haemoglobin concentration. We examined associations between ZPP and disorders that are common in Africa. In addition, we assessed the diagnostic utility of ZPP (measured in whole blood and erythrocytes), alone or in combination with haemoglobin concentration, in detecting iron deficiency (plasma ferritin concentration <15 μg/L).MethodsSingle blood samples were collected from a population sample of 470 rural Kenyan women with singleton pregnancies, gestational age 13 to 23 weeks, and haemoglobin concentration ≥90 g/L. We used linear regression analysis to assess associations between ZPP and iron markers (including anaemia), factors known or suspected to be associated with iron status, inflammation markers (plasma concentrations of C-reactive protein and α1-acid glycoprotein), infections (Plasmodium infection, HIV infection), and other disorders (α+-thalassaemia, plasma concentrations of total bilirubin, and lactate dehydrogenase). Subsequently, in those without inflammation, Plasmodium infection, or HIV infection, we used logistic discriminant analysis and examined receiver operating characteristics curves with corresponding area-under-the-curve to assess diagnostic performance of ZPP, alone and in combination with haemoglobin concentration.ResultsIndividually, whole blood ZPP, erythrocyte ZPP, and erythrocyte protoporphyrin had limited ability to discriminate between women with and without iron deficiency. Combining each of these markers with haemoglobin concentration had no additional diagnostic value. Conventional cut off points for whole blood ZPP (>70 μmol/mol haem) resulted in gross overestimates of the prevalence of iron deficiency.ConclusionsErythrocyte ZPP has limited value to rule out iron deficiency when used for screening in conditions with a low prevalence (e.g., 10%). ZPP is of unreliable diagnostic utility when discriminating between pregnant women with and without iron deficiency. Based on these findings, guidelines on the use of ZPP to assess iron status in individuals or populations of pregnant women need review.Trial registrationNCT01308112 (2 March 2011).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.