An isolated heart setup including an RBP was developed, which combines the advantages of in silico/vitro methods and animal experiments. This tool thus provides further insight into the interaction between the heart and an RBP.
Ventricular assist devices (VADs) are an established therapeutic option for patients with chronic heart failure. Continuous monitoring of VAD parameters and their adherence to guidelines are crucial to detect problems in an early stage to optimize outcomes. A telephone intervention algorithm for VAD outpatients was developed, clinically implemented and evaluated. During the phone calls, a structured inquiry of pump parameters, alarms, blood pressure, INR, body weight and temperature, exit‐site status and heart failure symptoms was performed and electronically categorized by an algorithm into 5 levels of severity. VAD outpatient outcomes without (n = 71) and with bi‐weekly telephone interviews in their usual care (n = 25) were conducted using proportional hazard Cox regression, with risk adjustment based on a propensity score model computed from demographics and risk factors. From February 2015 through October 2017, 25 patients (n = 3 HeartMate II, n = 4 HeartMate 3 and n = 18 HeartWare HVAD) underwent 637 telephone interventions. In 57.5% of the calls no problems were identified, 3.9% were recalled on the next day because of alarms. In 26.5% (n = 169), the VAD Coordinator had to refer to the physician due to elevated blood pressure (n = 125, >85 mm Hg), INR < 2.0 or > 4.0 (n = 24) or edema (n = 10), 11.9% of the calls led to a follow‐up because of equipment or exit‐site problems. Propensity‐adjusted 2‐year survival (89% vs. 57%, P = 0.027) was significantly higher for the telephone intervention group. Continuous, standardized communication with VAD outpatients is important for early detection of upcoming problems and leads to significantly improved survival.
BACKGROUND
There is an increasing use of extracorporeal life support in refractory cardiac arrest. Recent studies highlighted the importance of an early and accurate patient selection for this invasive procedure.
OBJECTIVES
The aim of this study was to retrospectively validate a six-criteria-screening-checklist (witnessed collapse, bystander-cardiopulmonary resuscitation/first medical contact <5 min, shockable, age <70 years, end tidal carbon dioxide >14 mmHg and pupils not anisocoric/distorted/mydriatic) as an early screening tool in patients treated with extracorporeal cardiopulmonary resuscitation (eCPR) at the emergency department.
DESIGN
Retrospective observational study.
SETTING/PATIENTS
All patients at least 18 years of age with nontraumatic cardiac arrest and without return of spontaneous circulation before eCPR treatment at our department between January 2013 and December 2018 were included in this retrospective observational study.
INTERVENTION
No specific intervention was set in this observational study.
MAIN OUTCOME MEASURES
Primary outcome was the rate of patients who fulfilled all criteria, secondary outcome was 30-day and 6-month survival in accordance with the criteria.
RESULTS
Overall, data from a total of 92 patients were eligible for analyses. Out of these, 27 patients (29%) met all criteria. Patients, who fulfilled all criteria, showed significantly higher odds for 30-day survival [OR 6.0 (95% CI 1.78 to 20.19)] P
= 0.004. Patients, who did not fulfil all criteria, showed significantly higher rates of early mortality after eCPR initiation [OR 4.57 (95% CI 1.69 to 12.37)] P
= 0.003.
CONCLUSION
Patients fulfilling all inclusion criteria showed higher rates of survival after eCPR. Our results affirm that there is a possibility and even an obvious necessity for early patient selection based on standardised criteria before eCPR treatment. Large randomised trials are urgently needed to answer this question accurately.
Even small linguistic differences can lead to critical differences in the usability and, thus, the safety of VAD peripherals. Detailed discussions with professional translators and/or practical tests of failure scenarios may optimize usability.
Polycytemia vera (PV) is a rare myeloproliferative neoplasm associated with microcirculatory disturbances, thrombosis and bleeding. Patients suffering from PV have a high risk of perioperative adverse events, but the literature regarding on‐pump procedures in PV patients is scarce. We report two cases of acute and severe oxygenator failure during cardiopulmonary bypass and present valid exit scenarios.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.