Formic acid is a promising energy carrier for on-demand hydrogen generation. Because the reverse reaction is also feasible, formic acid is a form of stored hydrogen. Here we present a robust, reusable iridium catalyst that enables hydrogen gas release from neat formic acid. This catalysis works under mild conditions in the presence of air, is highly selective and affords millions of turnovers. While many catalysts exist for both formic acid dehydrogenation and carbon dioxide reduction, solutions to date on hydrogen gas release rely on volatile components that reduce the weight content of stored hydrogen and/or introduce fuel cell poisons. These are avoided here. The catalyst utilizes an interesting chemical mechanism, which is described on the basis of kinetic and synthetic experiments.
Controlling oxygen concentration at a microscale level can benefit experimental investigations involving oxidative stress, ischemia, and reactive oxygen species (ROS) mediated cellular pathways. Here, we report the application of microfluidic gradient generation in an open-well culture model, in which a gradient of gas is delivered via diffusion through a gas permeable substrate that separates cells from the gas microchannels below. By using diffusion to localize oxygen delivery, microgradients of oxygen concentrations can be rapidly and controllably applied without exposing cells to mechanical stresses or reducing culture volumes inside microfluidic culture chambers. Furthermore, we demonstrate the modulation of intracellular ROS levels in Madin-Darby canine kidney (MDCK) cells by applying these oxygen microgradients. Increases in ROS levels consistent with both oxidative stress and hypoxic exposures were observed in MDCK cells. The measured ROS increases were comparable to 100 μM hydrogen peroxide exposure in a control comparison, which is within the range of standard ROS induction methods. Incubation with 200 μM vitamin C was able to demodulate the ROS response at both hypoxic and hyperoxic exposures. By providing microfluidic controlled gradients, constant ROS exposure, and a shear-free open well design, the devices introduced here greatly improve upon standard oxygen-based culturing methods. Illustration Content List Entry with Summary Sentence The devices presented here can generate complex oxygen gradients over rapid timescales, permitting investigation of a number of difficult-to-model physiological systems.
Simultaneous stimulation of ex vivo pancreatic islets with dynamic oxygen and glucose is a critical technique for studying how hypoxia alters glucose-stimulated response, especially in transplant environments. Standard techniques using a hypoxic chamber cannot provide both oxygen and glucose modulations while monitoring stimulus-secretion coupling factors in real-time. Using novel microfluidic device with integrated glucose and oxygen modulations, we quantified hypoxic impairment of islet response by calcium influx, mitochondrial potentials, and insulin secretion. Glucose-induced calcium response magnitude and phase were suppressed by hypoxia, while mitochondrial hyperpolarization and insulin secretion decreased in coordination. More importantly, hypoxic response was improved by preconditioning islets to intermittent hypoxia (IH, 1min/1min 5%–21% cycling for 1 hour), translating to improved insulin secretion. Moreover, blocking mitochondrial KATP channels removed preconditioning benefits of IH, similar to mechanisms in preconditioned cardiomyocytes. Additionally, the multimodal device can be applied to a variety of dynamic oxygen-metabolic studies in other ex vivo tissues.
In this report, we present a novel microfluidic islet array based on a hydrodynamic trapping principle. The lab-on-a-chip studies with live-cell multiparametric imaging allow understanding of physiological and pathophysiological changes of microencapsulated islets under hypoxic conditions. Using this microfluidic array and imaging analysis techniques, we demonstrate that hypoxia impairs the function of microencapsulated islets at single islet level, showing a heterogeneous pattern reflected in intracellular calcium signaling, mitochondrial energetic, and redox activity. Our approach demonstrates an improvement over conventional hypoxia chambers that is able to rapidly equilibrate to true hypoxia levels through the integration of dynamic oxygenation. This work demonstrates the feasibility of array-based cellular analysis and opens up new modality to conduct informative analysis and cell-based screening for microencapsulated pancreatic islets.
Carbon fiber-reinforced polymers (CFRPs) are structural composites used in the aerospace and sporting goods industries. Their chief appeal lies in their high specific properties, which generally outperform metallic counterparts. There is a contemporary need for viable methods for recycling CRFPs at the end of their lifecycles and for utilizing the considerable production waste (ca. 30%) of CFRP part manufacturing. The cost associated with these waste streams is a principal economic driver inhibiting the penetration of CRFPs into larger-scale manufacturing, particularly in the automotive industry. Reported techniques for CRFP degradation involve pyrolysis or mechanical grinding of the CFRP, processes which are outlawed in some jurisdictions and can reduce the thermomechanical properties of the recycled products. In this study, we report a conceptually different approach to degrading a commercial blended benzoxazine/epoxy resin under mild, oxidative conditions. The thermosetting resin is polymerized, characterized, and then catalytically depolymerized via hydride abstraction with a ruthenium catalyst. These results demonstrate a concept for sustainable recycling of CFRP composites.
β-cells respond to blood glucose by secreting insulin to maintain glucose homeostasis. Perifusion enables manipulation of biological and chemical cues in elucidating the mechanisms of β-cell physiology. Recently, microfluidic devices made of polydimethylsiloxane and Borofloat glass have been developed as miniaturized perifusion setups and demonstrated distinct advantages over conventional techniques in resolving rapid secretory and metabolic waveforms intrinsic to β-cells. In order to enhance sensing and monitoring capabilities, these devices have been integrated with analytical tools to increase assay throughput. The spatio-temporal resolutions of these analyses have been improved through enhanced flow control, valves and compartmentalization. For the first time, this review provides an overview of current devices used in islet studies and analyzes their strengths and experimental suitability. To realize the potential of microfluidic islet applications, it is essential to bridge the gap in design and application between engineers and biologists through the creation of standardized bioassays and user-friendly interfaces.
Restoring tissue oxygenation has the potential to improve poorly healing wounds with impaired microvasculature. Compared to more established wound therapy using hyperbaric oxygen chambers, topical oxygen therapy has lower cost and better patient comfort, although topical devices have provided inconsistent results. To provide controlled topical oxygen while minimizing moisture loss, a major issue for topical oxygen, we’ve devised a novel wound bandage based on microfluidic diffusion delivery of oxygen. In addition to modulating oxygen from 0–100% in 60s rise time, the microfluidic oxygen bandage provides a conformal seal around the wound. When 100% oxygen is delivered, it penetrates wound tissues as measured in agar phantom and in vivo wounds. Using this microfluidic bandage, we applied the oxygen modulation to 8 mm excisional wounds prepared on diabetic mice. Treatment with the microfluidic bandage demonstrated improved collagen maturity in the wound bed, although only marginal differences were observed in total collagen, microvasculature, and external closure rates. Our results show that proper topical oxygen can improve wound parameters underneath the surface. Because of the ease of fabrication, the oxygen bandage represents an economical yet practical method for oxygen wound research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.