Standardized visualization of electro-or mechanoanatomical data allows easy inter-and intra-patient comparison. For this purpose, we developed the opensource and freely available UNISYS (Universal Ventricular Bullseye Visualization) software. A patientspecific mesh of the ventricular anatomy typically consists of a certain number of vertices and their associated values. Based on a limited amount of user inputs, the algorithm transforms these 3D single-layer coordinates to a circular 2D disk ('bullseye') through a number of translations and rotations, and interpolates them to achieve a continuous standardized visualization. The algorithm shows a high degree of bidirectionality and a robust spatial preservation of points of interest.
Background: The optimal way to determine repolarization time (RT) from the intracardiac unipolar electrogram (UEG) has been a topic of debate for decades. RT is typically determined by either the Wyatt method or the “alternative method,” which both consider UEG T-wave slope, but differently.Objective: To determine the optimal method to measure RT on the UEG.Methods: Seven pig hearts surrounded by an epicardial sock with 100 electrodes were Langendorff-perfused with selective cannulation of the left anterior descending (LAD) coronary artery and submersed in a torso-shaped tank containing 256 electrodes on the torso surface. Repolarization was prolonged in the non-LAD-regions by infusing dofetilide and shortened in the LAD-region using pinacidil. RT was determined by the Wyatt (tWyatt) and alternative (tAlt) methods, in both invasive (recorded with epicardial electrodes) and in non-invasive UEGs (reconstructed with electrocardiographic imaging). tWyatt and tAlt were compared to local effective refractory period (ERP).Results: With contact mapping, mean absolute error (MAE) of tWyatt and tAlt vs. ERP were 21 ms and 71 ms, respectively. Positive T-waves typically had an earlier ERP than negative T-waves, in line with theory. tWyatt -but not tAlt-shortened by local infusion of pinacidil. Similar results were found for the non-invasive UEGs (MAE of tWyatt and tAlt vs. ERP were 30 ms and 92 ms, respectively).Conclusion: The Wyatt method is the most accurate to determine RT from (non) invasive UEGs, based on novel and historical analyses. Using it to determine RT could unify and facilitate repolarization assessment and amplify its role in cardiac electrophysiology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.