This study tested whether a self-etching surface agent and the conventional hydrofluoric acid (HF) would provide the same bonding capacity between resin cement and feldspathic (Fd) and lithium disilicate (Ld) ceramics. Ceramic blocks were cut with a low-speed diamond saw with water cooling (Isomet 1000, Buehler, Lake Bluff, IL, USA) into 20 blocks of 5 × 7 × 4 mm, which were ground flat in a polishing machine (EcoMet/AutoMet 250, Buehler) under water cooling. The blocks were randomly divided into eight groups (n=5), according to ceramic type (Ld or Fd), surface conditioning (HF + Monobond Plus or Etch and Prime), and aging by thermocycling (TC or absence-baseline). After 24 hours in 37°C distilled water, blocks were embedded into acrylic resin and 1-mm cross-section beams composed of ceramic/cement/composite were obtained. The microtensile test was performed in a universal testing machine (DL-1000, EMIC, São José dos Campos, Brazil; 0.5 mm.min, 50 kgf load cell). Bond strength (MPa) was calculated by dividing the load at failure (in N) by the bonded area (mm). The fractured specimens were examined under stereomicroscopy, and one representative sample of each group was randomly selected before the cementation and was further used for analysis using scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS). The self-etching agent showed the highest bond strength for Fd (24.66±4.5) and Ld (24.73±6.9) ceramics and a decrease in surface wettability. SEM and EDS showed the presence of similar components in the tested materials with different topographies for both. Therefore, the self-etching primer was able to deliver even higher bonding than HF+silane to a resin cement.
Objective
To study the fracture resistance and stress distribution pattern of translucent zirconia and fiber-reinforced composite cantilever resin-bonded fixed dental prostheses (RPFDPs) with two retainer designs.
Materials and methods
Forty human mandibular molars were divided into two groups according to the retainer design. The restorations included a premolar pontic and 2 retainer designs: (D1) inlay ring retainer and (D2) lingual coverage retainer. Each main group was then divided according to the material used (n = 10): zirconia (Z) or fiber-reinforced composite (FRC) (F). Restorations were cemented using dual polymerizing adhesive luting resin. All specimens were thermo-cycled (5–55 °C for 10,000 cycles), then subjected to dynamic loading (50 N, 240,000, and 1.6 Hz) and fracture resistance test. The finite element analysis includes the two models of retainer designs used in the in vitro test. Modified von Mises stress values on enamel, dentin, luting resin, and restorations were examined when the restorations failed.
Results
A significantly higher failure load was recorded for zirconia groups (505.00 ± 61.50 and 548.00 ± 75.63 N for D1Z and D2Z, respectively) than for FRC groups (345.00 ± 42.33 and 375.10 ± 53.62 N for D1F and D2F, respectively) (P = 0.001). With regard to failure mode, D2 showed a more favorable failure pattern than D1. Model D2 resulted in lower stresses in tooth structure than model D1, and zirconia transmitted more stresses to the tooth structure than FRC.
Conclusions
The lingual coverage retainer (D2) enhanced the biomechanical performance of the restoration/tooth complex. Considering the failure mode and tooth stress, FRC is a promising treatment option when constructing a cantilever RPFDP.
Clinical relevance
Dentists should be aware of the biomechanical behavior during the selection of the material and for the replacement of a single missing mandibular premolar tooth with minimally invasive RBFDP.
To evaluate the fracture load and stress magnitude of different retainer designs of minimally invasive cantilever resin-bonded fixed dental prostheses (RBFDPs) after artificial aging. Materials and methods: Fifty caries-free human mandibular molars were prepared as abutments for cantilever fixed dental prostheses using different retainer designs: one wing (OW), two wings (TW), inlay ring (IR), lingual coverage (LC), and occlusal coverage (OC). Computer-aided design and computer-aided manufacturing were used for milling the RBFDPs using fiber-reinforced composite (FRC), and the restorations were adhesively bonded. The specimens were then subjected to thermomechanical aging and loaded until failure. The 3D finite element analysis (FEA) was performed with five models of retainer designs similar to the in vitro test. Modified von Mises stress values on enamel, dentine, luting resin, and restorations were examined. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests (p < 0.001). Results: A statistically significant difference (p < 0.001) was found between all groups except between IR and LC and between OW and TW designs, with the highest mean failure load detected for OC (534.70 N) and the lowest detected for OW (129.80 N). With regard to failure mode, OW, TW, and LC showed more incidences of favorable failure patterns than IR and OC designs. FEA showed that FRC transmitted low stresses in tooth structure and high stresses to the luting resin. Conclusions: LC and OC designs can be used to design cantilever RBFDPs in premolar area. IR design transmitted more stresses to the tooth structure and resulted in 30% catastrophic failure. OW and TW were below the normal occlusal force and should be carefully used.
The goal of this study was to compare the mechanical response of resin-bonded fixed dental prosthesis (RBFDP) made in zirconia, metal, lithium disilicate and composite resin cemented using resin cements with different elastic modulus. For the finite element analysis, a three-dimensional model of partial right maxilla was used to create a model with edentulous space in the second premolar and the cavity's preparation on the first pre-molar and first molar to receive a RBFDP. The model was imported to the analysis software in which they were divided into mesh composed by nodes (371,101) and tetrahedral elements (213,673). Each material was considered isotropic, elastic and homogeneous. No-separation contacts were considered between restoration/resin cement and resin cement/tooth. For all other structures the contacts were considered ideal. The model fixation occurred at the base of the bone and an axial load of 300 N was applied on the pontic occlusal surface. To simulate polymerization shrinkage effects on the cement, the thermal expansion approach was used. The displacement and maximum principal stress (in MPa) were selected as failure criteria. The prosthesis made in composite resin showed higher displacement, while in zirconia showed higher stress concentration. Tensile stress between restoration/cement, cement and cement/cavity was directly proportional to the restorative material's elastic modulus. The more rigid cement increases the tensile zones in the cement layer but decreases the stress between prosthesis and cement. The molar cavity showed higher stress concentration between restoration/cement than the preparation in the pre-molar tooth. The use of composite resin for the manufacturing of RBFDP increases the displacement of the set during the loading. However, it reduces the amount of stress concentration at the adhesive interface in comparison with the other materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.