Magnetic compression technique (MCT) is a popular new anastomosis method. In this paper, we aimed to explore the feasibility of use of MCT for performing cystotomy in rabbits. The parent magnets and daughter magnets for rabbit cystostomy were designed and manufactured according to the anatomical characteristics of rabbit lower urinary tract. Twelve female New Zealand rabbits were used as animal models. After anesthesia, a daughter magnet was inserted into the bladder through the urethra, and the parent magnet was placed on the body surface projection of the bladder over the abdominal wall. The two magnets automatically attract each other. Postoperatively, the state of magnets was monitored daily, and the time when the magnets fell off was recorded. Cystostomy with MCT was successfully performed in all twelve rabbits. The mean operation time was 4.46 ± 0.75 min. The magnets fell off from the abdominal wall after a mean duration of 10.08 ± 1.62 days, resulting in the formation of bladder fistula. Macroscopic and microscopic examination showed that the fistula was well formed and unobstructed. The junction between bladder and abdominal wall was tight and smooth. We provide preliminary experimental evidence of the safety and feasibility of cystostomy based on MCT.
Magnetic anchor device based on the principle of magnet heteropolar attraction can assist laparoscopic surgery and reduce abdominal wall trauma. This study explored the feasibility of use of our self-designed magnetic anchor device for reduced-port laparoscopic cholecystectomy (LC) through animal experiments. Twelve experimental pigs (15–20 kg) were randomly divided into study group (magnetic anchor technique assisted 2-port LC, n = 6) and control group (conventional 3-port LC, n = 6). Operative time, intraoperative blood loss, and postoperative complications were compared between the two groups. LC was successfully performed in all 12 pigs. There was no significant between-group difference with respect to operative time (study group: 35.83 ± 5.12 min; control group: 34.50 ± 5.13 min, P = 0.662) or intraoperative blood loss (< 50 mL per animal in both groups). In the experimental group, there was no malfunction of the magnetic anchoring device, the use process was smooth, and the tissue traction and surgical field exposure were satisfactory. There were no perioperative complications such as bile duct injury, bile leakage, or bleeding in both groups. We demonstrated the feasibility of use of the self-designed magnetic anchor device in reduced-port LC. The device has important clinical application value.
Magnetic compression technique (MCT) is a popular new anastomosis method. In this paper, we aimed to explore the feasibility of use of MCT for performing cystotomy in rabbits. The parent magnets and daughter magnets for rabbit cystostomy were designed and manufactured according to the anatomical characteristics of rabbit lower urinary tract. Twelve female New Zealand rabbits were used as animal models. After anesthesia, a daughter magnet was inserted into the bladder through the urethra, and the parent magnet was placed on the body surface projection of the bladder over the abdominal wall. The two magnets automatically attract each other. Postoperatively, the state of magnets was monitored daily, and the time when the magnets fell off was recorded. Cystostomy with MCT was successfully performed in all twelve rabbits. The mean operation time was 4.46 ± 0.75 min. The magnets fell off from the abdominal wall after a mean duration of 10.08 ± 1.62 days, resulting in the formation of bladder fistula. Macroscopic and microscopic examination showed that the fistula was well formed and unobstructed. The junction between bladder and abdominal wall was tight and smooth. We provide preliminary experimental evidence of the safety and feasibility of cystostomy based on MCT.
above the posterior aponeurosis; intraperitoneal (IPOM) -mesh adjacent to the transversalis fascia. After 60 days of the act, adhesions, tensiometry (maximum tension strengh; MTS), histology and immunohistochemistry (mannose receptors and CD 68 expression) were evaluated.RESULTS: IPOM obtained the highest number of adhesions, with an average of 3.4 (p <0.0001). SL presented higher values in the tensiometric evaluation, mean of 36.75 N and lower mean IPOM, 6.58 N (p <0.0001). Histology demonstrated greater expression of the production of inflammatory, polymorphonuclear cells and fibroblasts in SL (p <0.0001). Immunohistochemical findings showed greater expression of mannose receptors and CD68 receptors in the SL group (p 0,01 and p 0,001, respectively). CONCLUSION:The mesh in the retromuscular compartment caused an increase in tensiometry. The intraperitoneal group showed an exacerbated intensity of adhesions. The histological and immunohistochemical findings reinforce demonstrate an optimized healing process in the SL group. We affirm that corrections of incisional hernias by the retromuscular technique generate a better fibrogenesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.