This study was conducted according to the method presented in the Republic of Korea Pharmacopoeia 11th Revision, aseptic test method to evaluate the suitability of sterilization for a sterile needle (4 Pin Multi-needle). In this study, four tests were conducted: sterility test, cytotoxicity test, acute toxicity test, skin sensitization test. First, in the aseptic test, the microorganism was not proliferated in the aseptic test of the medium. As a result of the performance test of the medium, it was confirmed that the microorganism developed within 3 days and the fungus was evident within 5 days. Based on this, it was confirmed that the medium was suitable, and as a result of the aseptic test, the development of microorganisms was not observed during the total culture period. Based on these results, tests were conducted which were confirmed to be suitable for aseptic testing because the development of bacteria on the provided samples was not recognized. For cytotoxicity tests ISO10993-5; 2009 (Biological Evaluation of Medical Devices, Part 5: Test for in vitro Cytotoxicity). As a result, the MEM eluate of the test substance caused very slight cytotoxicity to the fibroblasts of the mouse and was judged to be Grade 1 (Slightly cytotoxic) according to the judgment standard of ISO 10993-5. On the other hand, solvent control, negative control and positive control showed the expected results on the test. Acute Toxicity Test Results: It was judged that there was no systemic toxicity change when ICR mice were treated with 50 mL/kg B.W. of the eluate of sterile injectable needle for 72 hours. Skin sensitization test result: The Hartley guinea pig was evaluated as a substance which is evaluated as a substance which does not induce any skin reaction when skin sensitization is applied to the dissected material of the sterile injectable needle and is weak in skin sensitivity. Based on the above tests, we will study the stability and efficacy of more reliable medical devices based on the verification and performance of medical devices.
At relatively low effort level tasks, surface electromyogram (sEMG) spectral parameters have demonstrated an inconsistent ability to monitor localized muscle fatigue and predict endurance capacity. The main purpose of this study was to assess the potential of the endurance time (Tend) prediction using logarithmic parameters compared to raw data. Ten healthy subjects performed five sets of voluntary isotonic contractions until their exhaustion at 20% of their maximum voluntary contraction (MVC) level. We extracted five sEMG spectral parameters namely the power in the low frequency band (LFB), the mean power frequency (MPF), the high-to-low ratio between two frequency bands (H/L-FB), the Dimitrov spectral index (DSI), and the high-to-low ratio between two spectral moments (H/L-SM), and then converted them to logarithms. Changes in these ten parameters were monitored using area ratio and linear regressive slope as statistical predictors and estimating from onset at every 10% of Tend. Significant correlations (r > 0.5) were found between log(Tend) and the linear regressive slopes in the logarithmic H/L-SM at every 10% of Tend. In conclusion, logarithmic parameters can be used to describe changes in the fatigue content of sEMG and can be employed as a better predictor of Tend in comparison to the raw parameters.
Abstract. In this study, the radiation generated in the diagnosis of scoliosis, to solve the problems by using an infrared camera and an optical marker system that can diagnose scoliosis developed. System developed by the infrared camera attached to the optical spinal curvature is recognized as a marker to shoot the angle between the two optical markers are measured. Measurement of angle, we used the Cobb's Angle method used in the diagnosis of spinal scoliosis. We developed a software to be able to output to the screen using an infrared camera to diagnose spinal scoliosis. Software is composed of camera output unit was manufactured in Labview, angle measurement unit, in Cobb's Angle measurement unit .In the future, kyphosis, Hallux Valgus, such as the diagnosis of orthopedic disorders that require the use of a diagnostic system is expected case.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.