Three-dimensional (3D) reconstruction in single-particle cryo-electron microscopy (cryo-EM) is a significant technique for recovering the 3D structure of proteins or other biological macromolecules from their two-dimensional (2D) noisy projection images taken from unknown random directions. Class averaging in single-particle cryo-EM is an important procedure for producing high-quality initial 3D structures, where image alignment is a fundamental step. In this paper, an efficient image alignment algorithm using 2D interpolation in the frequency domain of images is proposed to improve the estimation accuracy of alignment parameters of rotation angles and translational shifts between the two projection images, which can obtain subpixel and subangle accuracy. The proposed algorithm firstly uses the Fourier transform of two projection images to calculate a discrete cross-correlation matrix and then performs the 2D interpolation around the maximum value in the cross-correlation matrix. The alignment parameters are directly determined according to the position of the maximum value in the cross-correlation matrix after interpolation. Furthermore, the proposed image alignment algorithm and a spectral clustering algorithm are used to compute class averages for single-particle 3D reconstruction. The proposed image alignment algorithm is firstly tested on a Lena image and two cryo-EM datasets. Results show that the proposed image alignment algorithm can estimate the alignment parameters accurately and efficiently. The proposed method is also used to reconstruct preliminary 3D structures from a simulated cryo-EM dataset and a real cryo-EM dataset and to compare them with RELION. Experimental results show that the proposed method can obtain more high-quality class averages than RELION and can obtain higher reconstruction resolution than RELION even without iteration.
Single-particle analysis (SPA) in cryo-electron microscopy has become a powerful tool for determining and studying the macromolecular structure at an atomic level. However, since the SPA problem is a non-convex optimization problem with enormous search space and there is high level of noise in the input images, the existing methods may produce biased or even wrong final models. In this work, to deal with the problem, consistent constraints from the input data are explored in an embedding space, a 3D spherical surface. More specifically, the orientation of a projection image is represented by two intersection points of the normal vector and the local X-axis vector of the projection image on the unit spherical surface. To determine the orientations of the projection images, the global consistency constraints of the relative orientations of all the projection images are satisfied by two spherical embeddings which estimate the normal vectors and the local X-axis vectors of the projection images respectively. Compared to the traditional methods, the proposed method is shown to be able to rectify the initial computation errors and produce a more accurate estimation of the projection angles, which results in a better final model reconstruction from the noisy image data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.