A technique using the single-string, closed-loop fixation method to reposit dislocated triple-looped haptic intraocular lens (IOL)–capsular bag complex is described. The long needle or curved needle with a 10-0/8-0 polypropylene suture and a 27/30-gauge needle were used as the guide needle to pass through the fenestrated haptics twice. The scleral interlaminar course was used as the fixed point. Last, a fixation knot was created in the sclerotomy by the 2 ends of the thread to close the suture loop for IOL fixation. Another knot was created about 2 to 3 mm from the exit point and was intrasclerally anchored by the aid of the attached needle. 4 eyes from 4 consecutive patients were studied retrospectively; during all follow-up visits, the IOLs were well centered and stable, and no suture erosion, hypotony, scleral atrophy, chronic inflammation, retinal tears, and/or detachments were observed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.