The number of used batteries is expected to dramatically increase in the near future due to the expansion of the electric vehicle (EV) market globally. Accordingly, the Korean government has improved the supporting structures for the recycling system for used batteries, and in particular, in the field of repurposing, various studies are being conducted with a focus on effective evaluation methods that can secure the performance and safety of batteries after use. The repurposing of used batteries is mostly adapted in the field of energy storage systems for normally used EV batteries and a total inspection before repurposing is required due to battery characteristics that can vary depending on the operational environments of and accidents involving medium- and large-sized batteries for EVs and energy storage systems (ESSs) that have been occurring continuously for the past few years. Therefore, this paper investigates the operating mechanisms of the internal resistance test method and implements a test device for middle- and large-sized cells and packs. Based on the proposed test method, the internal resistance of nickel manganese cobalt (NMC)-type commercial large batteries is analyzed according to the SOC (state of charge), SOH (state of health), ambient temperature, and connection degradation of batteries. The distribution degrees of the alternative current (AC) internal resistance (IR) and direct current (DC) internal resistance (IR) measurement methods under state of health (SOH) test conditions are about 7% and 50%. It was found that the DC IR measurement method is more effective in diagnosing battery cell degradation. The distribution degree of DC IR measurements for the degraded connection condition shows an increase of less than 1% regardless of the state of charge (SOC), while the distribution degree of the AC IR measurements shows an increase of up to 319%, indicating that the AC IR method is more effective than the DC IR method in identifying connection degradation. It is confirmed that the proposed method is effective in internal resistance measurement and safety evaluations for the repurposing of batteries.
Generally, PV (photovoltaic) modules are known as devices which are used semi-permanently for more than 20 years, but the electrical performance and lifespan of PV modules can be significantly degraded due to various environmental factors. Thus, a proper evaluation method for aging phenomenon of PV modules is required. Although there already are methods which compare adjusted PV output power based on STC (standard test condition) with initial PV module specification, or perform direct comparison by conducting the test under STC, there are issues with objectivity or efficiency in the existing evaluation method of aging phenomenon due to the data distortion while adjusting measured data or difficulties in implementation. Therefore, in order to overcome the above-mentioned disadvantage of the existing evaluation method for deterioration in PV modules and evaluate the aging characteristics of PV modules based on on-site measurement data in an accurate and efficient manner, this paper implements a test device for aging diagnosis to measure and collect actual data from a PV module section, and presents a modeling of data analysis for aging phenomenon with MATLAB S/W in order to minimize the variability of PV output, communication error, delay, etc. Furthermore, this paper confirms the usefulness of the presented test device for aging diagnosis of the PV modules which is accurately evaluated by considering on-site measurement of PV output power by season.
In general, severe load imbalances in small AC micro-grid systems can degrade their operational performance and their maintenance. This is because the unbalanced load in the micro-grid affects the energy flow and the voltage regulation functions of each phase. In order to solve the voltage imbalance problem, several algorithms for the 3-phase 4-leg CVCF inverter have been proposed, but the control algorithms are not enough to operate the 4-leg CVCF inverter in a stable manner. Therefore, this paper proposes a single-phase voltage and power control algorithm for the 3-phase 4-leg CVCF inverter based on a dq control in order to improve the voltage imbalance problem caused by a severely unbalanced load, where the single phase voltage control algorithm is composed of an αβ-dq and a dq-αβ transformer, a voltage and a current controller, and an off-set controller and a PWM, and the single-phase power control algorithm is also composed of an αβ-dq and a dq-αβ transformer, an active/reactive power and a current controller, and an off-set controller and a PWM. Additionally, this paper performs modeling of the single-phase voltage and the power controller for a 4-leg CVCF inverter using the Matlab/Simulink S/W. From the simulation results, it is confirmed that the transient stability of the proposed single voltage control algorithm can be improved compared to the conventional control algorithm, and voltage control can also be maintained in a stable manner under extremely unbalanced conditions. Further, it is confirmed that 3-phase currents of the proposed single-phase power control algorithm are controlled in a stable manner under extremely unbalanced conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.