The durability of rheumatic mitral valve repair in the current era has improved and is comparable to the outstanding durability of repairs for degenerative disease, even in the adult rheumatic population. Modifications of standard repair techniques, adherence to the importance of good leaflet coaptation, and strict quality control with stringent use of intraoperative transesophageal echocardiography have all contributed to the improved long-term results.
The durability of MV repair for rheumatic disease in the current era has improved and is comparable with the outstanding durability of repairs for degenerative disease. Modifications of standard repair techniques, adherence to the importance of good leaflet coaptation and strict quality control with stringent use of intraoperative transoesophageal echocardiography have all contributed to the improved long-term results.
Repair with leaflet extension in rheumatic disease resulted in good early and mid-term outcomes. A wider utilization of this technique may increase the feasibility and durability of repair in complex rheumatic mitral valve disease.
MV repair can be successfully applied to both congenital and acquired MV disease in children. Aggressive repair techniques and avoidance of residual MR have improved durability and survival.
This case report describes a 20-year-old woman with Turner's syndrome who presented with reduced effort tolerance limited by dyspnea. She had previously been on pediatric cardiology follow-up for congenital subvalvular aortic stenosis first diagnosed at age 7. Unfortunately she defaulted after two visits before any intervention could be done. Transthoracic echocardiography demonstrated severe aortic incompetence (AI) with a membrane-like structure in the left ventricular outflow tract (LVOT). The mean pressure gradient across the LVOT on continuous wave Doppler was 41 mmHg. The membranous interventricular septum appeared aneurysmal and it was observed that the "subaortic membrane" had a connection to the anterolateral papillary muscle via a strand of chordal tissue. Further images were captured using two-dimensional and three-dimensional transthoracic and transesophageal echocardiography (iE33, Philips Medical Systems, Andover, MA, USA). After a review of the literature it was concluded that this appeared to be an accessory mitral valve (AMV) leaflet causing LVOT obstruction associated with AI. AMV tissue is a rare congenital malformation causing LVOT obstruction. Because it is so unusual, it may not be immediately recognizable even in a high volume echocardiography laboratory. The clue which helped with the diagnosis was the strand of chordal tissue which connected the mass to the papillary muscle. This anomaly is often associated with LVOT obstruction.
Twenty-three years of follow-up shows that MV repair is superior to MMVR in children with RHD. Hence, the rheumatic MV should be repaired when technically feasible to maximize the survival and reduce the valve-related morbidity with comparable durability to MMVR.
Background: The European System for Cardiac Operative Risk (EuroSCORE) II was developed in 2011 to replace the aging EUROScore for predicting in-house mortality after cardiac surgery. Our aim was to validate EuroSCORE II in Malaysian patients undergoing coronary artery bypass graft (CABG) surgery at our Institute. Methods: A retrospective single-center study was performed. A database was created to include EuroSCORE II values and actual mortality of 1718 patients undergoing CABG surgery in Malaysia from 1st January to 31st December 2016. The goodness-of-fit of EuroSCORE II was determined by the Hosmer-Lemeshow goodness-of-fit test and discriminatory power with the areas under the receiver operating characteristics (ROC) curve (AUC). Results: Observed mortality rate was 4.66% (80 out of 1718 patients). The median EuroSCORE II value was 2.06% (Inter Quartile Range: 1.94%) (1st quartile: 1.45%, 3rd quartile: 3.39%). The AUC for EuroSCORE II was 0.7 (95% CI 0.640 – 0.759) indicating good discriminatory power. The Hosmer-Lemeshow goodness-of-fit test did not show significant difference between expected and observed mortality in accordance to the EuroSCORE II model (Chi-square = 13.758, p = 0.089) suggesting good calibration of the model in this population. Cross-tabulation analysis showed that there is slight overestimation of EuroSCORE II in low-risk groups (0-10%) and slight underestimation in high-risk groups (>20%). Multivariate logistic regression analysis showed that gender, age, total hospital stay, serum creatinine and critical pre-operative state are significant predictors of mortality post-CABG surgery. Conclusion: This study indicated that the EuroSCORE II is a good predictor of post-operative mortality in the context of Malaysian patients undergoing CABG surgery. Our study also showed that certain independent variables might possess higher weightage in predicting mortality among this patient group. Therefore, it is suggested that EuroSCORE II can be safely used for risk assessment while ideally, clinical consideration should be applied on an individual basis.
Physiologically, blood ejected from the left ventricle in systole exhibited spiral flow characteristics. This spiral flow has been proven to have several advantages such as lateral reduction of directed forces and thrombus formation, while it also appears to be clinically beneficial in suppressing neurological complications. In order to deliver spiral flow characteristics during cardiopulmonary bypass operation, several modifications have been made on an aortic cannula either at the internal or at the outflow tip; these modifications have proven to yield better hemodynamic performances compared to standard cannula. However, there is no modification done at the inlet part of the aortic cannula for inducing spiral flow so far. This study was carried out by attaching a spiral inducer at the inlet of an aortic cannula. Then, the hemodynamic performances of the new cannula were compared with the standard straight tip end-hole cannula. This is achieved by modeling the cannula and attaching the cannula at a patient-specific aorta model. Numerical approach was utilized to evaluate the hemodynamic performance, and a water jet impact experiment was used to demonstrate the jet force generated by the cannula. The new spiral flow aortic cannula has shown some improvements by reducing approximately 21% of impinging velocity near to the aortic wall, and more than 58% reduction on total force generated as compared to standard cannula.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.