TAE of the prostate can induce shrinkage of the prostate without compromising the sexual desire and erectile function of animals. This finding suggests that TAE has potential as an alternative treatment for symptomatic benign prostatic hyperplasia in humans.
In conclusion, the cortical bone thickness and Schneider membrane characteristics in Merina sheep and Murciano-Granadina goat allow a perfect training for the modified Caldwell-Luc procedure. However, the approach from the oral cavity needs, in these species, a previous enlargement of the buccal vestibule. The excessive thickness of the cortical bone restricts the use of pigs for this technique.
Suturing technique is of paramount importance in microsurgery. Basic training in this technique can be done using the practice card, a purpose-made polyurethane card. A practice card has been designed in the Minimally Invasive Surgery Centre to closely resemble microsurgical requirements in order to practice and learn correct microsuturing maneuvers. This practice card is a key part of microsurgical training. After many years of experience, and based on a survey we conducted, we can conclude that this practice card is essential for step-by-step microsurgical training. Using this card, the number of animals required to attain necessary microsurgical skills is reduced significantly. Furthermore, costs are also reduced, and the trainee can avoid mistakes during training with live animals, thus optimizing results.
Transarterial prostatic embolization is a safe procedure that can induce prostatic infarction and ablate the prostate. The findings suggest the procedure has potential clinical applications in the care of patients with benign prostatic hyperplasia.
Virtual reality simulators need haptic devices with force feedback capability if tissue consistency information is to be delivered. On the other hand, the visual haptics concept has been associated with a kind of tactile memory developed by surgical experience.
The purpose of this study was to develop an abdominal aortic aneurysm model that more closely resembles the morphology of human aneurysms with potential for further growth of the sac. An infrarenal abdominal aortic aneurysm (AAA) model was created with a double-layered peritoneal patch in 27 domestic swine. The patch, measuring in average from 6 to 12 cm in length and from 2 to 3 cm in width, was sutured to the edge of an aortotomy. Pre- and postsurgical digital subtraction aortograms (DSA) were obtained to document the appearance and dimensions of the aneurysm. All animals were followed with DSA for up to 5 months. Laparoscopic examination enhanced by the use of laparoscopic ultrasound was also carried out in 2 animals to assess the aneurysm at 30 and 60 days following surgery. Histological examination was performed on 4 animals. All the animals that underwent the surgical creation of the AAA survived the surgical procedure. Postsurgical DSA demonstrated the presence of the AAA in all animals, defined as more than 50% increase in diameter. The aneurysmal mean diameter increased from the baseline of 10.27 +/- 1.24 to 16.69 +/- 2.29 mm immediately after surgery, to 27.6 +/- 6.59 mm at 14 days, 32.45 +/- 8.76 mm at 30 days (p < 0.01), and subsequently decreased to 25.98 +/- 3.75 mm at 60 days. A total of 15 animals died of aneurysmal rupture that occurred more frequently in the long aneurysms (> or =6 cm in length) than the short aneurysms (<6 cm in length) during the first 2 weeks after surgery (p <0.05). No rupture occurred beyond 16 days after surgery. Four animals survived and underwent 60-day angiographic follow-up. Laparoscopic follow-up showed strong pulses, a reddish external appearance and undetectable suture lines on the aneurysmal wall. On pathology, the patches were well incorporated into the aortic wall, the luminal wall appeared almost completely endothelialized, and cellular and matrix proliferation were noted in the aneurysmal wall. A reproducible technique for the creation of an infrarenal AAA model was developed using a peritoneal patch in swine. The aneurysm model proved to have potential for further growth of the sac and a tendency to rupture. Because of the growth potential, this might be a better model than those with a noncompliant aneurysmal wall for the preclinical evaluation of stent-graft devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.