In clinical routine, lower limb analysis relies on conventional X-ray (2D view) or computerised tomography (CT) Scan (lying position). However, these methods do not allow 3D analysis in standing position. The aim of this study is to propose a fast and accurate 3D-reconstruction-method based on parametric models and statistical inferences from biplanar X-rays with clinical measurements' (CM) assessment in standing position for a clinical routine use. For the reproducibility study, the 95% CI was under 2.7° for all lower limbs' angular measurements except for tibial torsion, femoral torsion and tibiofemoral rotation ( < 5°). The 95% CI were under 2.5 mm for lower limbs' lengths and 1.5 to 3° for the pelvis' CM. Comparisons between X-rays and CT-scan based 3D shapes in vitro showed mean differences of 1.0 mm (95% CI = 2.4 mm). Comparisons of 2D lower limbs' and 3D pelvis' CM between standing 'Shifted-Feet' and 'Non-Shifted-Feet' position showed means differences of 0.0 to 1.4°. Significant differences were found only for pelvic obliquity and rotation. The reconstruction time was about 5 min.
is an open access repository that collects the work of Arts et Métiers ParisTech researchers and makes it freely available over the web where possible.This is an author-deposited version published in: http://sam.ensam.eu Handle
Accurate localization of joint centers is essential in movement analysis. However, joint centers cannot be directly palpated and alternative methods must be used. To assess the relative merits of these methods, a medical image based reference should be used. The EOS(®) system, a new low dose bi-planar X-rays imaging technique may be considered. The aim of this study was to evaluate the accuracy of hip joint center (HJC) localization using the EOS(®) system. Seventeen healthy young adults participated in the study. Femoral heads and pelvic external markers were localized using the EOS(®) system and the HJCs were expressed in the movement analysis coordinate system. Results showed that external marker localization was reliable within 0.15 mm for trained assessors. Mean accuracy for HJC localization was 2.9 mm (SD: 1.3, max: 6.2). The EOS based method therefore appeared reliable and may be used for femoral head localization or as a reference to assess the accuracy of other methods for HJC localization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.