Insulin secretion rates can be accurately estimated from plasma C-peptide levels with a two-compartment model for C-peptide distribution and degradation. In previous studies, the kinetic parameters of C-peptide clearance were derived in each subject from the decay curve observed after bolus intravenous injection of biosynthetic human C-peptide. To determine whether standard parameters for C-peptide clearance could be defined and used to calculate insulin secretion without obtaining a decay curve in each subject, we analyzed 200 decay curves of biosynthetic human C-peptide obtained in normal, obese, and non-insulin-dependent diabetes mellitus subjects studied in our laboratory. This analysis showed that the volume of distribution and kinetic parameters of C-peptide distribution and metabolism vary by less than 30% in a population highly heterogeneous in terms of age, sex, degree of obesity, and degree of glucose tolerance. The volume of distribution correlated with the degree of obesity as quantified by body surface area (BSA). This dependence of C-peptide distribution volume on BSA was more marked in men than in women. The long half-life was slightly longer in elderly subjects than in younger adults. When effects of BSA, sex, and age were taken into account, the parameters of C-peptide kinetics were very similar in normal, obese, and diabetic subjects. Based on these findings, a simple procedure to derive standard parameters for C-peptide clearance taking into account degree of obesity, sex, and age was defined. These standard parameters resulted in estimations of mean insulin secretion rates, which differed in each subject by only 10-12% from those obtained with individual parameters. The approach of using standard rather than individual parameters did not systematically underestimate or overestimate insulin secretion so that group values for the fasting secretion rate, the mean 24-h secretion rate, and the number and the amplitude of secretory pulses obtained with standard parameters differed by only 1-2% from the values obtained with individual parameters. Furthermore, the accuracy of measurements based on standard parameters was not different from that associated with replicate determinations of the parameters of C-peptide clearance in the same subject. We conclude that it is possible to estimate insulin secretion rates from plasma C-peptide levels with standard parameters for C-peptide clearance rather than individually derived parameters without significant loss of accuracy.
Glucagon-like peptide 1 (GLP-1) is potentially a very attractive agent for treating type 2 diabetes. We explored the effect of short-term (1 week) treatment with a GLP-1 derivative, liraglutide (NN2211), on 24-h dynamics in glycemia and circulating free fatty acids, islet cell hormone profiles, and gastric emptying during meals using acetaminophen. Furthermore, fasting endogenous glucose release and gluconeogenesis (3-3 Hglucose infusion and 2 H 2 O ingestion, respectively) were determined, and aspects of pancreatic islet cell function were elucidated on the subsequent day using homeostasis model assessment and first-and second-phase insulin response during a hyperglycemic clamp (plasma glucose ϳ16 mmol/l), and, finally, on top of hyperglycemia, an arginine stimulation test was performed. For accomplishing this, 13 patients with type 2 diabetes were examined in a double-blind, placebo-controlled crossover design. Liraglutide (6 g/kg) was administered subcutaneously once daily. Liraglutide significantly reduced the 24-h area under the curve for glucose (P ؍ 0.01) and glucagon (P ؍ 0.04), whereas the area under the curve for circulating free fatty acids was unaltered. Twenty-four-hour insulin secretion rates as assessed by deconvolution of serum C-peptide concentrations were unchanged, indicating a relative increase. Gastric emptying was not influenced at the dose of liraglutide used. Fasting endogenous glucose release was decreased (P ؍ 0.04) as a result of a reduced glycogenolysis (P ؍ 0.01), whereas gluconeogenesis was unaltered. First-phase insulin response and the insulin response to an arginine stimulation test with the presence of hyperglycemia were markedly increased (P < 0.001), whereas the proinsulin/insulin ratio fell (P ؍ 0.001). The disposition index (peak insulin concentration after intravenous bolus of glucose multiplied by insulin sensitivity as assessed by homeostasis model assessment) almost doubled during liraglutide treatment (P < 0.01). Both during hyperglycemia per se and after arginine exposure, the glucagon responses were reduced during liraglutide administration (P < 0.01 and P ؍ 0.01). Thus, 1 week's treatment with a single daily dose of the GLP-1 derivative liraglutide, operating through several different mechanisms including an ameliorated pancreatic islet cell function in individuals with type 2 diabetes, improves glycemic control throughout 24 h of daily living, i.e., prandial and nocturnal periods. This study further emphasizes GLP-1 and its derivatives as a promising novel concept for treatment of type 2 diabetes.
Oscillations in human insulin secretion have been observed in two distinct period ranges, 10-15 min (i.e. rapid) and 100-150 min (i.e., ultradian). The cause of the ultradian oscillations remains to be elucidated. To determine whether the oscillations could result from the feedback loops between insulin and glucose, a parsimonious mathematical model including the major mechanisms involved in glucose regulation was developed. This model comprises two major negative feedback loops describing the effects of insulin on glucose utilization and glucose production, respectively, and both loops include the stimulatory effect of glucose on insulin secretion. Model formulations and parameters are representative of results from published clinical investigations. The occurrence of sustained insulin and glucose oscillations was found to be dependent on two essential features: 1) a time delay of 30-45 min for the effect of insulin on glucose production and 2) a sluggish effect of insulin on glucose utilization, because insulin acts from a compartment remote from plasma. When these characteristics were incorporated in the model, numerical simulations mimicked all experimental findings so far observed for these ultradian oscillations, including 1) self-sustained oscillations during constant glucose infusion at various rates; 2) damped oscillations after meal or oral glucose ingestion; 3) increased amplitude of oscillation after increased stimulation of insulin secretion, without change in frequency; and 4) slight advance of the glucose oscillation compared with the insulin oscillation.(ABSTRACT TRUNCATED AT 250 WORDS)
Insulin secretion rates can be accurately estimated from plasma C-peptide levels with a two-compartment model for C-peptide distribution and degradation. In previous studies, the kinetic parameters of C-peptide clearance were derived in each subject from the decay curve observed after bolus intravenous injection of biosynthetic human C-peptide. To determine whether standard parameters for C-peptide clearance could be defined and used to calculate insulin secretion without obtaining a decay curve in each subject, we analyzed 200 decay curves of biosynthetic human C-peptide obtained in normal, obese, and non-insulin-dependent diabetes mellitus subjects studied in our laboratory. This analysis showed that the volume of distribution and kinetic parameters of C-peptide distribution and metabolism vary by less than 30% in a population highly heterogeneous in terms of age, sex, degree of obesity, and degree of glucose tolerance. The volume of distribution correlated with the degree of obesity as quantified by body surface area (BSA). This dependence of C-peptide distribution volume on BSA was more marked in men than in women. The long half-life was slightly longer in elderly subjects than in younger adults. When effects of BSA, sex, and age were taken into account, the parameters of C-peptide kinetics were very similar in normal, obese, and diabetic subjects. Based on these findings, a simple procedure to derive standard parameters for C-peptide clearance taking into account degree of obesity, sex, and age was defined. These standard parameters resulted in estimations of mean insulin secretion rates, which differed in each subject by only 10-12% from those obtained with individual parameters. The approach of using standard rather than individual parameters did not systematically underestimate or overestimate insulin secretion so that group values for the fasting secretion rate, the mean 24-h secretion rate, and the number and the amplitude of secretory pulses obtained with standard parameters differed by only 1-2% from the values obtained with individual parameters. Furthermore, the accuracy of measurements based on standard parameters was not different from that associated with replicate determinations of the parameters of C-peptide clearance in the same subject. We conclude that it is possible to estimate insulin secretion rates from plasma C-peptide levels with standard parameters for C-peptide clearance rather than individually derived parameters without significant loss of accuracy.
OBJECTIVE—The primary objective of the present study was to investigate the safety, tolerability, and pharmacokinetics of a single dose of NN2211, a long-acting glucagon-like peptide 1 (GLP-1) derivative, in healthy male subjects. The secondary objective was to investigate the pharmacodynamics of NN2211. RESEARCH DESIGN AND METHODS—In a double-blind, randomized dose, escalation, placebo-controlled study, healthy male subjects were enrolled at eight consecutive dose levels (1.25, 2.5, 5.0, 10.0, 12.5, 15.0, 17.5, and 20.0 μg/kg) with eight subjects per dose level at a 3:1 active:placebo randomization. After subcutaneous dosing with NN2211, 48-h pharmacokinetic, and 24-h glucose, insulin and glucagon profiles were assessed. In addition, three subjects at each dose level were randomly assigned (one placebo/two active) to an intravenous glucose tolerance test (IVGTT) 9 h after the dose (corresponding to the time to maximal plasma concentration of NN2211). RESULTS—After subcutaneous administration, the half-life of NN2211 was found to be 11–15 h. Overall, although there were no statistically significant differences compared with placebo in the area under the curve (0–9 h for insulin or glucagon), there was a borderline- significant lowering of glucose levels (P = 0.066). During the IVGTT, there was a statistically significant increase in insulin secretion (P = 0.0002), but there was no significant effect on glucagon levels. Although no significant effect was observed on glucose levels during the IVGTT, there was a dose-dependent increase in the glucose disappearance constant. Whereas no serious adverse events were observed, there was a higher incidence of adverse events after active treatment compared with placebo treatment (notably headache, dizziness, nausea, and vomiting). CONCLUSIONS—This study provides evidence that NN2211 has a pharmacokinetic profile consistent with once-daily dosing in humans.
Pancreatic (-cell function was studied in six subjects with mutations in the enzyme glucokinase (GCK) who were found to have elevated fasting and postprandial glucose levels in comparison to six normoglycemic controls. Insulin secretion rates (ISRs) were estimated by deconvolution of peripheral C-peptide values using a two-compartment model and individual Cpeptide kinetics obtained after bolus intravenous injections of biosynthetic human C-peptide. First-phase insulin secretory responses to intravenous glucose and insulin secretion rates over a 24-h period on a weight maintenance diet were not different in subjects with GCK mutations and controls. However, the dose-response curve relating glucose and ISR obtained during graded intravenous glucose infusions was shifted to the right in the subjects with GCK mutations and average ISRs over a glucose range between 5 and 9 mM were 61% lower than those in controls. In the controls, the ft cell was most sensitive to an increase in glucose at concentrations between 5.5 and 6.0 mM, whereas in the patients with GCK mutations the point of maximal responsiveness was increased to between 6.5 and 7.5 mM. Even mutations that resulted in mild impairment of in vitro enzyme activity were associated with a > 50% reduction in ISR. The responsiveness of the (3 cell to glucose was increased by 45% in the subjects with mutations after a 42-h intravenous glucose infusion at a rate of 4-6 mg/kg per min. During oscillatory glucose infusion with a period of 144 min, profiles from the subjects with mutations revealed reduced spectral power at 144 min for glucose and ISR compared with controls, indicating decreased ability to entrain the 63 cell with exogenous glucose. In conclusion, subjects with mutations in GCK demonstrate decreased responsiveness of the (3 cell to glucose manifest by a shift in the glucose ISR dose-response curve to the right and reduced ability to entrain the ultradian oscillations of insulin secretion with exogenous glucose. These results support a key role for the enzyme GCK in determining the in vivo glucose/ ISR dose-response relationships and define the alterations in ,8-cell responsiveness that occur in subjects with GCK mutations. (J. Clin. Invest. 1994.93:1120-1130
The increased prevalence of non-insulin-dependent diabetes mellitus (NIDDM) among women with polycystic ovary syndrome (PCOS) has been ascribed to the insulin resistance characteristic of PCOS. This study was undertaken to determine the role of defects in insulin secretion as well as familial factors to the predisposition to NIDDM seen in PCOS. We studied three groups of women: PCOS with a family history of NIDDM (PCOS FHx POS; n = 11), PCOS without a family history of NIDDM (PCOS FHx NEG; n = 13), and women without PCOS who have a family history of NIDDM (NON-PCOS FHx POS; n = 8). Beta cell function was evaluated during a frequently sampled intravenous glucose tolerance test, by a low dose graded glucose infusion, and by the ability of the beta cell to be entrained by an oscillatory glucose infusion. PCOS FHx POS women were significantly less likely to demonstrate appropriate beta cell compensation for the degree of insulin resistance. The ability of the beta cell to entrain, as judged by the spectral power for insulin secretion rate, was significantly reduced in PCOS FHx POS subjects. In conclusion, a history of NIDDM in a first-degree relative appears to define a subset of PCOS subjects with a greater prevalence of insulin secretory defects. The risk of developing NIDDM imparted by insulin
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.