Considering the low incidence of regional lymph node recurrence and the levels with frequent regional recurrence in patients without lymph node metastasis, elective neck dissection in all cases of total thyroidectomy may be immoderate. However, if any risk factors for regional recurrence, including large tumor size, presence of extrathyroid spread, high T stage, and presence of lymph node metastasis, are detected by preoperative and intraoperative evaluation, a systematic compartment-oriented lymphadenectomy should be considered because of the high possibility of regional recurrence.
Electric stimuli can prosthetically excite auditory nerve fibers to partially restore sensory function to individuals impaired by profound or severe hearing loss. While basic response properties of electrically stimulated auditory nerve fibers (ANF) are known, responses to complex, time-changing stimuli used clinically are inadequately understood. We report that forward-masker pulse trains can enhance and reduce ANF responsiveness to subsequent stimuli and the novel observation that sub-threshold (nonspike-evoking) electric trains can reduce responsiveness to subsequent pulse-train stimuli. The effect is observed in the responses of cat ANFs and shown by a computational biophysical ANF model that simulates rate adaptation through integration of external potassium cation (K) channels. Both low-threshold (i.e., Klt) and high-threshold (Kht) channels were simulated at each node of Ranvier. Model versions without Klt channels did not produce the sub-threshold effect. These results suggest that some such accumulation mechanism, along with Klt channels, may underlie sub-threshold masking observed in cat ANF responses. As multichannel auditory prostheses typically present sub-threshold stimuli to various ANF subsets, there is clear relevance of these findings to clinical situations.
The hypothesis of this study was that broader patterns of physiological channel interactions in the local region of the cochlea are associated with poorer spectral resolution in the same region. Electrically evoked compound action potentials (ECAPs) were measured for three to six probe electrodes per subject to examine the channel interactions in different regions across the electrode array. To evaluate spectral resolution at a confined location within the cochlea, spectral-ripple discrimination (SRD) was measured using narrowband ripple stimuli with the bandwidth spanning five electrodes: Two electrodes apical and basal to the ECAP probe electrode. The relationship between the physiological channel interactions, spectral resolution in the local cochlear region, and vowel identification was evaluated. Results showed that (1) there was within- and across-subject variability in the widths of ECAP channel interaction functions and in narrowband SRD performance, (2) significant correlations were found between the widths of the ECAP functions and narrowband SRD thresholds, and between mean bandwidths of ECAP functions averaged across multiple probe electrodes and broadband SRD performance across subjects, and (3) the global spectral resolution reflecting the entire electrode array, not the local region, predicts vowel identification.
Voice- and swallowing-related discomfort in patients who received thyroidectomy showed dynamic changes over time. There was a significant difference in the degree of change according to clinicopathological factors. Patients with these risk factors may benefit from appropriate patient education and various rehabilitation programs for symptom relief.
Evidence of visual-auditory cross-modal plasticity in deaf individuals has been widely reported. Superior visual abilities of deaf individuals have been shown to result in enhanced reactivity to visual events and/or enhanced peripheral spatial attention. The goal of this study was to investigate the association between visual-auditory cross-modal plasticity and speech perception in post-lingually deafened, adult cochlear implant (CI) users. Post-lingually deafened adults with CIs (N = 14) and a group of normal hearing, adult controls (N = 12) participated in this study. The CI participants were divided into a good performer group (good CI, N = 7) and a poor performer group (poor CI, N = 7) based on word recognition scores. Visual evoked potentials (VEP) were recorded from the temporal and occipital cortex to assess reactivity. Visual field (VF) testing was used to assess spatial attention and Goldmann perimetry measures were analyzed to identify differences across groups in the VF. The association of the amplitude of the P1 VEP response over the right temporal or occipital cortex among three groups (control, good CI, poor CI) was analyzed. In addition, the association between VF by different stimuli and word perception score was evaluated. The P1 VEP amplitude recorded from the right temporal cortex was larger in the group of poorly performing CI users than the group of good performers. The P1 amplitude recorded from electrodes near the occipital cortex was smaller for the poor performing group. P1 VEP amplitude in right temporal lobe was negatively correlated with speech perception outcomes for the CI participants (r = -0.736, P = 0.003). However, P1 VEP amplitude measures recorded from near the occipital cortex had a positive correlation with speech perception outcome in the CI participants (r = 0.775, P = 0.001). In VF analysis, CI users showed narrowed central VF (VF to low intensity stimuli). However, their far peripheral VF (VF to high intensity stimuli) was not different from the controls. In addition, the extent of their central VF was positively correlated with speech perception outcome (r = 0.669, P = 0.009). Persistent visual activation in right temporal cortex even after CI causes negative effect on outcome in post-lingual deaf adults. We interpret these results to suggest that insufficient intra-modal (visual) compensation by the occipital cortex may cause negative effects on outcome. Based on our results, it appears that a narrowed central VF could help identify CI users with poor outcomes with their device.
Response rates of auditory nerve fibers (ANFs) to electric pulse trains change over time, reflecting substantial spike-rate adaptation that depends on stimulus parameters. We hypothesize that adaptation affects the representation of amplitude-modulated pulse trains used by cochlear prostheses to transmit speech information to the auditory system. We recorded cat ANF responses to sinusoidally amplitude-modulated (SAM) trains with 5,000 pulse/s carriers. Stimuli delivered by a monopolar intracochlear electrode had fixed modulation frequency (100 Hz) and depth (10%). ANF responses were assessed by spike-rate measures, while representation of modulation was evaluated by vector strength (VS) and the fundamental component of the fast Fourier transform (F 0 amplitude). These measures were assessed across the 400 ms duration of pulse-train stimuli, a duration relevant to speech stimuli. Different stimulus levels were explored and responses were categorized into four spike-rate groups to assess level effects across ANFs. The temporal pattern of rate adaptation to modulated trains was similar to that of unmodulated trains, but with less rate adaptation. VS to the modulator increased over time and tended to saturate at lower spike rates, while F 0 amplitude typically decreased over time for low driven rates and increased for higher driven rates. VS at moderate and high spike rates and degree of F 0 amplitude temporal changes at low and moderate spike rates were positively correlated with the degree of rate adaptation. Thus, high-rate carriers will modify the ANF representation of the modulator over time. As the VS and F 0 measures were sensitive to adaptation-related changes over different spike-rate ranges, there is value in assessing both measures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.