Aims: At present, clinical success of hepatocyte transplantation as an alternative to whole liver transplantation is hampered by the limited availability of suitable donor organs for the isolation of transplantable hepatocytes. Hence, novel cell sources are required to deliver hepatocytes of adequate quality for clinical use. Mesenchymal stem cells (MSCs) from human bone marrow may have the potential to differentiate into hepatocytes in vitro and in vivo. Methods: Isolated MSCs were selected by density gradient centrifugation and plastic adherence, differentiated in the presence of human hepatocyte growth medium and transplanted in immunodeficient Pfp/Rag2 mice. Results: Here, we demonstrate that human MSCs gain in vitro the characteristic morphology and function of hepatocytes in response to specified growth factors. Specifically, preconditioned MSCs store glycogen, synthesise urea and feature the active hepatocyte-specific gene promoter of phosphoenolpyruvate carboxykinase (PCK1). After transplantation into livers of immunodeficient mice, preconditioned MSCs engraft predominantly in the periportal portion of the liver lobule. In situ, the cells continue to store glycogen and express PCK1, connexin32, albumin and the human hepatocyte-specific antigen HepPar1, indicating that the transplanted cells retain prominent qualities of hepatocytes after their regional integration. Conclusion: MSCs derived from human bone marrow may serve as a novel source for the propagation of hepatocyte-like cells suitable for cell therapy in liver diseases.
Pan-intestinal capsule endoscopy seems to be feasible in the postoperative surveillance of Crohn's disease. Disease activity is reliably detected. Especially, the findings in the small bowl might be a significant advantage in comparison to ileo-colonoscopy, as they can have significant impact on clinical management. Further studies with a larger number of patients are needed to confirm these findings and might lead to a replacement of the flexible ileo-colonoscopy with pan-intestinal capsule endoscopy in this indication in the future.
Impairment of liver regeneration by propranolol is related to the inhibition of acute hepatic fat accumulation and to a predisposition of hepatocytes to apoptosis.
BACKGROUND & AIMS:Early detection of neoplastic lesions is essential in patients with long-standing ulcerative colitis but the best technique of colonoscopy still is controversial.
METHODS:We performed a prospective multicenter study in patients with long-standing ulcerative colitis. Two colonoscopies were performed in each patient within 3 weeks to 3 months. In white-light (WL) colonoscopy, stepwise random biopsy specimens (4 biopsy specimens every 10 cm), segmental random biopsies (2 biopsy specimens in 5 segments), and targeted biopsy specimens were taken. In NBI colonoscopy, segmental and targeted biopsy specimens were taken. The sequence of WL and NBI colonoscopy was randomized.
RESULTS:In 36 of 159 patients enrolled (22.6%), 54 lesions with intraepithelial neoplasia (IN) were found (51 low-grade, 3 high-grade). In WL colonoscopy we found 11 IN in stepwise biopsy specimens, 4 in segmental biopsy specimens, and 15 in targeted biopsy specimens. In NBI colonoscopy 7 IN were detected in segmental biopsy specimens and 24 IN were detected in targeted biopsy specimens. Almost all IN were found with one technique alone (k value of WL vs NBI, -0.86; P < .001). Statistically equivalent numbers of IN were found in NBI colonoscopywith targeted and segmental biopsy specimens as in WL colonoscopy with targeted and stepwise biopsy specimens, but with fewer biopsy specimens (11.9 vs 38.6 biopsy specimens, respectively; P < .001), and less withdrawal time was necessary (23 vs 13 min, respectively; P < .001).
CONCLUSIONS:Stepwise biopsy specimens are indispensable in WL colonoscopy. The combination of targeted and segmental biopsy specimens in the NBI technique is as sensitive as targeted together with stepwise biopsy specimens in WL colonoscopy, but requires fewer biopsy specimens and less time. The highest sensitivity should be reached by combining the WL and NBI techniques by switching between the modes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.