This paper reviews the centrifugal 'Bio-Disk' platform which is based on rotationally controlled, multi-scale liquid handling to fully integrate and automate complex analysis and synthesis protocols in the life sciences. The platform offers the crucial ingredients for a rapid development of applications: a coherent library of fluidic unit operations, a device technology for actuation, liquid interfacing and detection as well as a developer toolbox providing experimental testing, rapid prototyping and simulation capabilities. Various applications in the fields of life science, in vitro diagnostics and micro-process engineering are demonstrated.
We present two novel fluidic concepts to drastically accelerate the process of mixing in batch-mode (stopped-flow) on centrifugal microfluidic platforms. The core of our simple and robust setup exhibits a microstructured disk with a round mixing chamber rotating on a macroscopic drive unit. In the first approach, magnetic beads which are prefilled into the mixing chamber are periodically deflected by a set of permanent magnets equidistantly aligned at spatially fixed positions in the lab-frame. Their radial positions alternatingly deviate by a slight positive and negative offset from the mean orbit of the chamber to periodically deflect the beads inbound and outbound during rotation. Advection is induced by the relative motion of the beads with respect to the liquid which results from the magnetic and centrifugal forces, as well as inertia. In a second approach--without magnetic beads--the disk is spun upon periodic changes in the sense of rotation. This way, inertia effects induce stirring of the liquids. As a result, both strategies accelerate mixing from about 7 minutes for mere diffusion to less than five seconds. Combining both effects, an ultimate mixing time of less than one second could be achieved.
We present a centrifugal process for the extraction of plasma from sediment by a decanting structure, terminating with metered plasma which is readily available for subsequent on-disk processing. Our technique supplies 2 microl plasma from 5 microl of whole blood at moderate spinning frequencies of 40 Hz within 20 s, only. The residual cell concentration in the purified plasma amounts to less than 0.11%, independent of the frequency of rotation. A capillary duct connects the extracted plasma to subsequent on-disk processing units.
We present a novel, cost-efficient process chain for fast tooling and small-lot replication of high-quality, multi-scale microfluidic polymer chips within less than 5 days. The fabrication chain starts with a primary master which is made by well-established cleanroom processes such as DRIE or negative SU-8 resist based surface micromachining. The formation of undercuts in the master which would complicate demolding is carefully avoided. Secondary PDMS masters or epoxy-based masters which are more suitable for common polymer replication schemes such as soft-embossing, hot-embossing or injection molding are subsequently cast from the primary masters. The polymer replica are mainly made of COC and show excellent fidelity with the conventionally micromachined master while displaying no degeneration, even after more than 200 cycles. The use of other polymers such as PMMA is also possible. The process chain further includes surface modification techniques for overall, long-term stable hydrophilic coatings and for local hydrophobic patches as well as a durable sealing based on thermal bonding.
The centrifugal "lab-on-a-disc" concept has proven to have great potential for process integration of bioanalytical assays, in particular where ease-of-use, ruggedness, portability, fast turn-around time and cost efficiency are of paramount importance. Yet, as all liquids residing on the disc are exposed to the same centrifugal field, an inherent challenge of these systems remains the automation of multi-step, multi-liquid sample processing and subsequent detection. In order to orchestrate the underlying bioanalytical protocols, an ample palette of rotationally and externally actuated valving schemes has been developed. While excelling with the level of flow control, externally actuated valves require interaction with peripheral instrumentation, thus compromising the conceptual simplicity of the centrifugal platform. In turn, for rotationally controlled schemes, such as common capillary burst valves, typical manufacturing tolerances tend to limit the number of consecutive laboratory unit operations (LUOs) that can be automated on a single disc. In this paper, a major advancement on recently established dissolvable film (DF) valving is presented; for the very first time, a liquid handling sequence can be controlled in response to completion of preceding liquid transfer event, i.e. completely independent of external stimulus or changes in speed of disc rotation. The basic, event-triggered valve configuration is further adapted to leverage conditional, large-scale process integration. First, we demonstrate a fluidic network on a disc encompassing 10 discrete valving steps including logical relationships such as an AND-conditional as well as serial and parallel flow control. Then we present a disc which is capable of implementing common laboratory unit operations such as metering and selective routing of flows. Finally, as a pilot study, these functions are integrated on a single disc to automate a common, multi-step lab protocol for the extraction of total RNA from mammalian cell homogenate.
Thrombosis is common in ovarian cancer. However, the interaction of platelets with ovarian cancer cells has not been critically examined. To address this, we investigated platelet interactions in a range of ovarian cancer cell lines with different metastatic potentials [HIO-80, 59M, SK-OV-3, A2780, A2780cis]. Platelets adhered to ovarian cancer cells with the most significant adhesion to the 59M cell line. Ovarian cancer cells induced platelet activation [P-selectin expression] in a dose dependent manner, with the most significant activation seen in response to the 59M cell line. The platelet antagonists [cangrelor, MRS2179, and apyrase] inhibited 59M cell induced activation suggesting a P2Y12 and P2Y1 receptor mediated mechanism of platelet activation dependent on the release of ADP by 59M cells. A2780 and 59M cells potentiated PAR-1, PAR-4, and TxA2 receptor mediated platelet activation, but had no effect on ADP, epinephrine, or collagen induced activation. Analysis of gene expression changes in ovarian cancer cells following treatment with washed platelets or platelet releasate showed a subtle but valid upregulation of anti-apoptotic, anti-autophagy pro-angiogenic, pro-cell cycle and metabolic genes. Thus, ovarian cancer cells with different metastatic potential adhere and activate platelets differentially while both platelets and platelet releasate mediate pro-survival and pro-angiogenic signals in ovarian cancer cells.
In this article we introduce a novel technology that utilizes specialized water dissolvable thin films for valving in centrifugal microfluidic systems. In previous work (William Meathrel and Cathy Moritz, IVD Technologies, 2007), dissolvable films (DFs) have been assembled in laminar flow devices to form efficient sacrificial valves where DFs simply open by direct contact with liquid. Here, we build on the original DF valving scheme to leverage sophisticated, merely rotationally actuated vapour barriers and flow control for enabling comprehensive assay integration with low-complexity instrumentation on "lab-on-a-disc" platforms. The advanced sacrificial valving function is achieved by creating an inverted gas-liquid stack upstream of the DF during priming of the system. At low rotational speeds, a pocket of trapped air prevents a surface-tension stabilized liquid plug from wetting the DF membrane. However, high-speed rotation disrupts the metastable gas/liquid interface to wet the DF and thus opens the valve. By judicious choice of the radial position and geometry of the valve, the burst frequency can be tuned over a wide range of rotational speeds nearly 10 times greater than those attained by common capillary burst valves based on hydrophobic constrictions. The broad range of reproducible burst frequencies of the DF valves bears the potential for full integration and automation of comprehensive, multi-step biochemical assay protocols. In this report we demonstrate DF valving, discuss the biocompatibility of using the films, and show a potential sequential valving system including the on-demand release of on-board stored liquid reagents, fast centrifugal sedimentation and vigorous mixing; thus providing a viable basis for use in lab-on-a-disc platforms for point-of-care diagnostics and other life science applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.