This study was designed to determine the optimal intensity for verification phase testing (VP) in healthy, young adults. Thirty one young, active participants (16 females) completed a cycle ergometer graded exercise test (GXT) VO2max test and 4 VP tests at 80, 90, 100, and 105% of the maximum wattage achieved during the GXT. GXT and VP VO2max values showed a significant test x sex interaction (p = 0.02). The males elicited significantly higher VO2max values during the GXT, 80%, and 90% when compared to the 105%, (105 vs. GXT: p = 0.05; 105% vs. 80%: p < 0.01; 105% vs. 90%: p = 0.02). There were no significant differences in VO2max across the tests in the females (p > 0.05); 80% of the males achieved their highest VP VO2max during a submaximal VP test compared to only 37.5% of the females. A secondary study conducted showed excellent reliability (ICCs > 0.90) and low variation (CVs < 3%) for the 90% VP. Our findings show that a submaximal verification phase intensity is ideal for young healthy males to elicit the highest VO2max during cycle ergometer testing. For females, a range of intensities (80–105%) produce similar VO2max values. However, the 80% VP yields an unnecessarily high time to exhaustion.
The aim of the present study was to assess the validity of verification phase (VP) testing and a 3 min all-out test to determine critical power (CP) in males with obesity. Nine young adult males with a body mass index (BMI) ≥ 30 kg·m−2 completed a cycle ergometer ramp-style VO2max test, four randomized VP tests at 80, 90, 100, and 105% of maximum wattage attained during the ramp test, and a 3 min all-out test. There was a significant main effect for VO2max across all five tests (p = 0.049). Individually, 8 of 9 participants attained a higher VO2max (L/min) during a VP test compared to the ramp test. A trend (p = 0.06) was observed for VO2max during the 90% VP test (3.61 ± 0.54 L/min) when compared to the ramp test (3.37 ± 0.39 L/min). A significantly higher VO2max (p = 0.016) was found in the VP tests that occurred below 130% of CP wattage (N = 15, VO2max = 3.76 ± 0.52 L/min) compared to those that were above (N = 21, VO2max = 3.36 ± 0.41 L/min). Our findings suggest submaximal VP tests at 90% may elicit the highest VO2max in males with obesity and there may be merit in using % of CP wattage to determine optimal VP intensity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.