PURPOSE. To quantify and compare the structural and functional changes in subjects with early age-related macular degeneration (AMD), using spectral-domain optical coherence tomography (SD-OCT) and microperimetry.METHODS. Twenty-one eyes of 21 subjects with early AMD were examined. MP-1 10-2 visual fields (VFs) and SD-OCT line and detail volume scans were acquired. The thicknesses of the outer segment (OS; distance between inner segment ellipsoid band and upper retinal pigment epithelium [RPE] border) and RPE layers and elevation of the RPE from Bruch's membrane were measured using a computer-aided manual segmentation technique. Thickness values were compared with those for 15 controls, and values at locations with VF total deviation defects were compared with values at nondefect locations at equivalent eccentricities. RESULTS.Sixteen of 21 eyes with AMD had VF defects. Compared with controls, line scans showed significant thinning of the OS layer (P ¼ 0.006) and thickening and elevation of the RPE (P ¼ 0.037, P ¼ 0.002). The OS layer was significantly thinner in locations with VF defects compared with locations without defects (P ¼ 0.003). There was a negligible difference between the retinal layer thickness values of the 5 eyes without VF defects and the values of normal controls.CONCLUSIONS. In early AMD, when VF defects were present, there was significant thinning of the OS layer and thickening and elevation of the RPE. OS layer thinning was significantly associated with decreased visual sensitivity, consistent with known photoreceptor loss in early AMD. For AMD subjects without VF defects, thickness values were normal. The results highlight the clinical utility of both SD-OCT retinal layer quantification and VF testing in early AMD. (Invest Ophthalmol Vis Sci. 2012;53:7618-7624) DOI:10.1167/iovs.12-10361 A ge-related macular degeneration (AMD) is the third leading cause of blindness worldwide, accounting for 8.7% of blindness in the global population.1 Due to the increase in the average lifespan of the elderly population, it is expected that 17.8 million individuals in the United States will be affected by 2050.2 In view of the relevance of AMD as a public health issue, it is important to understand the changes that occur in the early stages of disease, which may lead to improved future intervention strategies.There has been recent interest in the use of fundus perimetry, also known as microperimetry, as an outcome measure in clinical trials of macular disease.3-7 Functional loss due to AMD was previously demonstrated by findings of reduced visual field sensitivity in retinal locations with drusen compared with nondrusen locations, using scanning laser ophthalmoscope (SLO) perimetry and microperimetry. [8][9][10][11] In contrast, other studies reported no difference in sensitivity between drusen and nondrusen areas. 12Optical coherence tomography (OCT) is a noninvasive imaging technique that provides cross-sectional images of retinal layer structure, useful for visualization of pathology. Spectral-domain O...
BackgroundClinically significant depressive symptoms are prevalent in people attending low vision clinics and often go undetected. The Low Vision Service Wales (LVSW) plans to introduce depression screening and management pathways. Prior to implementation there is an unmet need to understand how eye care practitioners providing the service currently address depression with patients, and the characteristics and beliefs that influence their practice.MethodsA mixed methods convergent design was employed. Twelve low vision practitioners were purposively selected to engage in individual semi-structured interviews which were analysed using thematic analysis. A further 167 practitioners were invited to complete a questionnaire assessing professional background, current practice, confidence and perceived barriers in working with people with low vision and suspected depression. Multiple regression analyses were performed to determine the characteristics related to the Rasch-transformed questionnaire scores.ResultsOf the 122 practitioners that responded to the questionnaire, 33% aimed to identify depression in patients, and those who were more confident were more likely to do so. Those who scored higher on the perceived barriers scale and lower on confidence were less likely to report acting in response to suspected depression (all p < 0.05). Three qualitative themes were identified; depression is an understandable response to low vision, patients themselves are a barrier to addressing depression and practitioners lacked confidence in their knowledge and skills to address depression. The qualitative data largely expanded the quantitative findings.ConclusionsPractitioners viewed their own lack of knowledge and confidence as a barrier to the identification and management of depression and expressed a need for training prior to the implementation of service changes. The study findings will help to inform the development of a training programme to support low vision practitioners and those working with other chronic illness in Wales, and internationally, in the identification and management of people with depression.
Purpose To compare visual fields on the Nidek MP-1 to those obtained on the Humphrey field analyzer (HFA) in healthy volunteers and assess the effects of differences in stimulus parameters and testing strategies that may influence the interpretation of results in patients. A secondary aim was to establish MP-1 normative data to calculate the total deviation analyses and global indices analogous to those used by the HFA. Methods 50 healthy volunteers (age 43.5 ± 13.9 yrs, range 18–68 yrs) underwent repeat MP-1 and HFA visual field testing, using the 10-2 pattern. MP-1 data were converted to HFA equivalent dB units. Between instrument comparisons of HFA and MP-1 sensitivities, regression of sensitivity with age, and examination duration were assessed. Test-retest variability was examined between visits. Results MP-1 (mean = 32.82 dB, SD = 1.92 dB) and HFA sensitivities (mean = 32.84 dB, SD = 1.83 dB) were not significantly different (p = 0.759). SD values for the HFA (range 1.11–3.30 dB) were similar to the MP-1 (range 0.14–2.75 dB). However asymmetry comparisons between instruments showed significantly decreased superior rather than inferior retinal values for the MP-1. There was a small but significant difference (p = 0.004) in mean test duration between the MP-1 (mean = 6:11 min, SD = 1:49 min) and the HFA (mean = 5:14 min, SD = 0:42 min). There was also a difference in the decline of mean sensitivity with age, a decline of 0.1 and 0.4dB per decade was noted in MP-1 and HFA sensitivity respectively. Test-retest variability was similar between instruments. A small but non-significant increase in mean sensitivity at the second visit for both the MP-1 (p = 0.060) and HFA (p = 0.570) was found. Conclusions Both instruments showed similar variability and test-retest variability when results were compared using equivalent units. However there are important differences in sensitivity values, stimulus parameters and testing strategies that have to be taken into account when comparisons are made.
Retinal and intra-retinal layer thicknesses are routinely generated from optical coherence tomography (OCT) images, but on-board software capabilities and image scaling assumptions are not consistent across devices. This study evaluates the device-independent Iowa Reference Algorithms (Iowa Institute for Biomedical Imaging) for automated intra-retinal layer segmentation and image scaling for three OCT systems. Healthy participants (n = 25) underwent macular volume scans using a Cirrus HD-OCT (Zeiss), 3D-OCT 1000 (Topcon), and a non-commercial long-wavelength (1040nm) OCT on two occasions. Mean thickness of 10 intra-retinal layers was measured in three ETDRS subfields (fovea, inner ring and outer ring) using the Iowa Reference Algorithms. Where available, total retinal thicknesses were measured using on-board software. Measured axial eye length (AEL)-dependent scaling was used throughout, with a comparison made to the system-specific fixed-AEL scaling. Inter-session repeatability and agreement between OCT systems and segmentation methods was assessed. Inter-session coefficient of repeatability (CoR) for the foveal subfield total retinal thickness was 3.43μm, 4.76μm, and 5.98μm for the Zeiss, Topcon, and long-wavelength images respectively. For the commercial software, CoR was 4.63μm (Zeiss) and 7.63μm (Topcon). The Iowa Reference Algorithms demonstrated higher repeatability than the on-board software and, in addition, reliably segmented all 10 intra-retinal layers. With fixed-AEL scaling, the algorithm produced significantly different thickness values for the three OCT devices (P<0.05), with these discrepancies generally characterized by an overall offset (bias) and correlations with axial eye length for the foveal subfield and outer ring (P<0.05). This correlation was reduced to an insignificant level in all cases when AEL-dependent scaling was used. Overall, the Iowa Reference Algorithms are viable for clinical and research use in healthy eyes imaged with these devices, however ocular biometry is required for accurate quantification of OCT images.
BackgroundAn evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10–2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD.Methods10–2 SAP and SWAP Humphrey visual fields and stereoscopic fundus photographs were collected in 27 eyes of 27 patients with AMD and 22 eyes of 22 normal subjects.ResultsMean Deviation and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post hoc analysis revealed overlap of functional values among stages. In SWAP, indices of focal loss were more sensitive to detecting differences in AMD from normal. SWAP defects were greater in depth and area than those in SAP. Central sensitivity (within 1°) changed by −3.9 and −4.9 dB per stage in SAP and SWAP, respectively. Based on defect maps, an AMD Severity Index was derived.ConclusionsGlobal indices of focal loss were more sensitive to detecting early stage AMD from normal. The SWAP sensitivity decline with advancing stage of AMD was greater than in SAP. A new AMD Severity Index quantifies visual field defects on a continuous scale. Although not all patients are suitable for SWAP examinations, it is of value as a tool in research studies of visual loss in AMD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.