Aims A multitude of cardiac magnetic resonance (CMR) techniques are used for myocardial strain assessment; however, studies comparing them are limited. We sought to compare global longitudinal (GLS), circumferential (GCS), segmental longitudinal (SLS), and segmental circumferential (SCS) strain values, as well as reproducibility between CMR feature tracking (FT), tagging (TAG), and fast-strain-encoded (fast-SENC) CMR techniques. Methods and results Eighteen subjects (11 healthy volunteers and seven patients with heart failure) underwent two CMR scans (1.5T, Philips) with identical parameters. Global and segmental strain values were measured using FT (Medis), TAG (Medviso), and fast-SENC (Myocardial Solutions). Friedman's test, linear regression, Pearson's correlation coefficient, and Bland-Altman analyses were used to assess differences and correlation in measured GLS and GCS between the techniques. Two-way mixed intra-class correlation coefficient (ICC), coefficient of variance (COV), and Bland-Altman analysis were used for reproducibility assessment. All techniques correlated closely for GLS (Pearson's r: 0.86-0.92) and GCS (Pearson's r: 0.85-0.94). Intra-observer and interobserver reproducibility was excellent in all techniques for both GLS (ICC 0.92-0.99, CoV 2.6-10.1%) and GCS (ICC 0.89-0.99, CoV 4.3-10.1%). Inter-study reproducibility was similar for all techniques for GLS (ICC 0.91-0.96, CoV 9.1-10.8%) and GCS (ICC 0.95-0.97, CoV 7.6-10.4%). Combined segmental intra-observer reproducibility was good in all techniques for SLS (ICC 0.914-0.953, CoV 12.35-24.73%) and SCS (ICC 0.885-0.978, CoV 10.76-19.66%). Combined inter-study SLS reproducibility was the worst in FT (ICC 0.329, CoV 42.99%), while fast-SENC performed the best (ICC 0.844, CoV 21.92%). TAG had the best reproducibility for combined inter-study SCS (ICC 0.902, CoV 19.08%), while FT performed the worst (ICC 0.766, CoV 32.35%). Bland-Altman analysis revealed considerable inter-technique biases for GLS (FT vs. fast-SENC 3.71%; FT vs. TAG 8.35%; and TAG vs. fast-SENC 4.54%) and GCS (FT vs. fast-SENC 2.15%; FT vs. TAG 6.92%; and TAG vs. fast-SENC 2.15%). Limits of agreement for GLS ranged from ±3.1 (TAG vs. fast-SENC) to ±4.85 (FT vs. TAG) for GLS and ±2.98 (TAG vs. fast-SENC) to ±5.85 (FT vs. TAG) for GCS. Conclusions We found significant differences in measured GLS and GCS between FT, TAG, and fast-SENC. Global strain reproducibility was excellent for all techniques. Acquisition-based techniques had better reproducibility than FT for segmental strain.
Background: Despite the ongoing global pandemic, the impact of COVID-19 on cardiac structure and function is still not completely understood. Myocarditis is a rare but potentially serious complication of other viral infections with variable recovery, and is, in some cases, associated with long-term cardiac remodeling and functional impairment.Aim: To assess myocardial injury in patients who recently recovered from an acute SARS-CoV-2 infection with advanced cardiac magnetic resonance imaging (CMR) and endomyocardial biopsy (EMB).Methods: In total, 32 patients with persistent cardiac symptoms after a COVID-19 infection, 22 patients with acute classic myocarditis not related to COVID-19, and 16 healthy volunteers were included in this study and underwent a comprehensive baseline CMR scan. Of these, 10 patients post COVID-19 and 13 with non-COVID-19 myocarditis underwent a follow-up scan. In 10 of the post-COVID-19 and 15 of the non-COVID-19 patients with myocarditis endomyocardial biopsy (EMB) with histological, immunohistological, and molecular analysis was performed.Results: In total, 10 (31%) patients with COVID-19 showed evidence of myocardial injury, eight (25%) presented with myocardial oedema, eight (25%) exhibited global or regional systolic left ventricular (LV) dysfunction, and nine (28%) exhibited impaired right ventricular (RV) function. However, only three (9%) of COVID-19 patients fulfilled updated CMR–Lake Louise criteria (LLC) for acute myocarditis. Regarding EMB, none of the COVID-19 patients but 87% of the non-COVID-19 patients with myocarditis presented histological findings in keeping with acute or chronic inflammation. COVID-19 patients with severe disease on the WHO scale presented with reduced biventricular longitudinal function, increased RV mass, and longer native T1 times compared with those with only mild or moderate disease.Conclusions: In our cohort, CMR and EMB findings revealed that SARS-CoV-2 infection was associated with relatively mild but variable cardiac involvement. More symptomatic COVID-19 patients and those with higher clinical care demands were more likely to exhibit chronic inflammation and impaired cardiac function compared to patients with milder forms of the disease.
Objectives We sought to: (1) determine the agreement in cardiovascular magnetic resonance (CMR) and speckle tracking echocardiography (STE) derived strain measurements, (2) compare their reproducibility, (3) determine which approach is best related to CMR late gadolinium enhancement (LGE). Background While STE-derived strain is routinely used to assess left ventricular (LV) function, CMR strain measurements are not yet standardized. Strain can be measured using dedicated pulse sequences (strain-encoding, SENC), or post-processing of cine images (feature tracking, FT). It is unclear whether these measurements are interchangeable, and whether strain can be used as an alternative to LGE. Methods Fifty patients underwent 2D echocardiography and 1.5 T CMR. Global longitudinal strain (GLS) was measured by STE (Epsilon), FT (NeoSoft) and SENC (Myocardial Solutions) and circumferential strain (GCS) by FT and SENC. Results GLS showed good inter-modality agreement ( r -values: 0.71–0.75), small biases (< 1%) but considerable limits of agreement (− 7 to 8%). The agreement between the CMR techniques was better for GLS than GCS (r = 0.81 vs 0.67; smaller bias). Repeated measurements showed low intra- and inter-observer variability for both GLS and GCS (intraclass correlations 0.86–0.99; coefficients of variation 3–13%). LGE was present in 22 (44%) of patients. Both SENC- and FT-derived GLS and GCS were associated with LGE, while STE-GLS was not. Irrespective of CMR technique, this association was stronger for GCS (AUC 0.77–0.78) than GLS (AUC 0.67–0.72) and STE-GLS (AUC = 0.58). Conclusion There is good inter-technique agreement in strain measurements, which were highly reproducible, irrespective of modality or analysis technique. GCS may better reflect the presence of underlying LGE than GLS.
Background.New-onset stage 4–5 chronic kidney disease (CKD) after liver transplantation (LT) is associated with high morbidity, mortality, and economic burden. In 2010, we instituted an early renal sparing immunosuppression (RSI) protocol for LT recipients with severe renal dysfunction (pre-LT dialysis/estimated glomerular filtration rate (eGFR)<30mL/min/1.73 m2 or post-LT acute kidney injury) consisting of 2 doses of basiliximab for induction and delaying tacrolimus to post-LT day 4–7. We examined the effect of early RSI on post-LT renal outcomes.Methods.Data on all adults who had LT between January 1, 2010, and December 12, 2014 were collected. We calculated the renal risk index (RRI) score for each LT recipient (https://rri.med.umich.edu). Primary outcome was new-onset post-LT stage 4–5 CKD.Results.Of 214 LT recipients, 121 (57%) received early RSI and 93 (43%) received standard immunosuppression. Cumulative incidence of new-onset stage 4–5 CKD was higher in early RSI compared with standard immunosuppression (P = 0.03). Female sex and RRI score were the significant risk factors for development of post-LT stage CKD in the entire study cohort as well as the LT recipients with RRI ≥ sixth decile (high-risk group).Conclusions.Delaying tacrolimus initiation combined with basiliximab induction did not have a durable effect on long-term renal outcomes in high-risk LT recipients. Further studies are needed to identify the effective strategies to preserve renal function by targeting patients at high risk for CKD progression.
Aim To evaluate the ability of single heartbeat fast-strain encoded (SENC) cardiovascular magnetic resonance (CMR) derived myocardial strain to discriminate between different forms of left ventricular (LV) hypertrophy (LVH). Methods 314 patients (228 with hypertensive heart disease (HHD), 45 with hypertrophic cardiomyopathy (HCM), 41 with amyloidosis, 22 competitive athletes, and 33 healthy controls) were systematically analysed. LV ejection fraction (LVEF), LV mass index and interventricular septal (IVS) thickness, T1 mapping and atypical late gadolinium enhancement (LGE) were assessed. In addition, the percentage of LV myocardial segments with strain ≤ − 17% (%normal myocardium) was determined. Results Patients with amyloidosis and HCM exhibited the highest IVS thickness (17.4 ± 3.3 mm and 17.4 ± 6 mm, respectively, p < 0.05 vs. all other groups), whereas patients with amyloidosis showed the highest LV mass index (95.1 ± 20.1 g/m2, p < 0.05 vs all others) and lower LVEF compared to controls (50.5 ± 9.8% vs 59.2 ± 5.5%, p < 0.05). Analysing subjects with mild to moderate hypertrophy (IVS 11–15 mm), %normal myocardium exhibited excellent and high precision, respectively for the differentiation between athletes vs. HCM (sensitivity and specificity = 100%, Area under the curve; AUC%normalmyocardium = 1.0, 95%CI = 0.85–1.0) and athletes vs. HHD (sensitivity = 83%, specificity = 75%, AUC%normalmyocardium = 0.85, 95%CI = 0.78–0.90). Combining %normal myocardial strain with atypical LGE provided high accuracy also for the differentiation of HHD vs. HCM (sensitivity = 82%, specificity = 100%, AUCcombination = 0.92, 95%CI = 0.88–0.95) and HCM vs. amyloidosis (sensitivity = 83%, specificity = 100%, AUCcombination = 0.83, 95%CI = 0.60–0.96). Conclusion Fast-SENC derived myocardial strain is a valuable tool for differentiating between athletes vs. HCM and athletes vs. HHD. Combining strain and LGE data is useful for differentiating between HHD vs. HCM and HCM vs. cardiac amyloidosis.
Myocardial feature-tracking (FT) deformation imaging is superior for risk stratification compared with volumetric approaches. Because there is no clear recommendation regarding FT postprocessing, we compared different FT-strain analyses with reference standard techniques, including tagging and strain-encoded (SENC) MRI. Methods: Feature-tracking software from four different vendors (TomTec, Medis, Circle [CVI], and Neosoft), tagging (Segment), and fastSENC (MyoStrain) were used to determine left ventricular global circumferential strains (GCS) and longitudinal strains (GLS) in 12 healthy volunteers and 12 patients with heart failure. Variability and agreements were assessed using intraclass correlation coefficients for absolute agreement (ICCa) and consistency (ICCc) as well as Pearson correlation coefficients. Results: For FT-GCS, consistency was excellent comparing different FT vendors
Background Right ventricular (RV) strain is a useful predictor of prognosis in various cardiovascular diseases, including those traditionally believed to impact only the left ventricle. We aimed to determine inter-modality and inter-technique agreement in RV longitudinal strain (LS) measurements between currently available cardiovascular magnetic resonance (CMR) and echocardiographic techniques, as well as their reproducibility and the impact of layer-specific strain measurements. Methods RV-LS was determined in 62 patients using 2D speckle tracking echocardiography (STE, Epsilon) and two CMR techniques: feature tracking (FT) and strain-encoding (SENC), and in 17 healthy subjects using FT and SENC only. Measurements included global and free-wall LS (GLS, FWLS). Inter-technique agreement was assessed using linear regression and Bland-Altman analysis. Reproducibility was quantified using intraclass correlation (ICC) and coefficients of variation (CoV). Results We found similar moderate agreement between both CMR techniques and STE in patients: r = 0.57–0.63 for SENC; r = 0.50–0.62 for FT. The correlation between SENC and STE was better for GLS (r = 0.63) than for FWLS (r = 0.57). Conversely, the correlation between FT and STE was higher for FWLS (r = 0.60–0.62) than GLS (r = 0.50–0.54). FT-midmyocardial strain correlated better with SENC and STE than FT-subendocardial strain. The agreement between SENC and FT was fair (r = 0.36–0.41, bias: − 6.4 to − 10.4%) in the entire study group. All techniques except FT showed excellent reproducibility (ICC: 0.62–0.96, CoV: 0.04–0.30). Conclusions We found only moderate inter-modality agreement with STE in RV-LS for both FT and SENC and poor agreement when comparing between the CMR techniques. Different modalities and techniques should not be used interchangeably to determine and monitor RV strain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.