of mobile-phase (B %) does not change during the separation. Isocratic elution is suitable for analysis of compounds with a relatively narrow range of polarity and hydrophobicity. In gradient elution, mobile phase strength (B %) increases during the separation. This means that sample retention is measured by k value decrease for each band as it migrates through the column [1-3]. Chromatographers are cautioned to avoid gradient elution when isocratic elution is possible to use. It is common knowledge that development and optimization of HPLC gradient methods can be time consuming and require many experiments [1,2]. Moreover, the transfer of a gradient elution method between columns, instruments and laboratories is notoriously more difficult than the transfer of an isocratic elution method [4,5]. Despite that gradient elution is a powerful method for separation and peak identification of many branches of chromatography provided that the optimum gradient profile, the profile that yields the best separation of the chromatographic peaks of a mixture of analytes can be easily determined [1-3, 6] The principal reason for using a gradient elution approach is a necessity to analyze samples containing solutes with a wide range of hydrophobicity [1-3, 6].As we mentioned before, optimization of gradient elution is a substantially more difficult task than optimization of isocratic conditions and can require many experiments, especially for multi-component samples [7][8][9][10]. Prediction of retention in gradient elution from structural formulae of analytes can potentially save time in method development, however, only a limited number of studies in this field have been published [11][12][13]. An approach described earlier requires many preliminary experiments to "train a column" and values of molecular descriptors which are mainly not known. Such an approach can be considered as theoretically interesting but without practical value [14][15][16]. The solvatic Abstract Application of the solvatic retention model of reversed-phase liquid chromatography was studied to predict retention of phenylisothiocyanate derivatives of amino acids from structural formulae and stationary and mobile phase properties. The gradient elution mode with methanol and acetonitrile aqueous mobile phases was used. It was shown that practically acceptable prediction or retention time values can be achieved after the first approximation step when experimental data of one run are used. The zero approximation level predictions-from structural formulae, column and mobile phase properties can be used as a "first guess" method from which further optimization can begin.
We report our experience with highly polar and charged analyte retention parameter prediction for a reversed-phase high-performance liquid chromatographic method. The solvatic retention model has been used to predict retention of phenylisothiocyanate derivatives of 25 natural amino acids under gradient elution conditions. Retention factors have been calculated from molecular parameters of analyte structures and from the column and eluent characteristics. A step-by-step method which includes the first guess prediction of initial conditions from structural formula and fine tuning of the retention model parameters using data from successive runs can substantially save method development time.
The separation of high-molecular compounds is very difficult, if possible at all, under isocratic conditions. For this gradient elution is needed. The theory of gradient elution for small molecules is well established; however, its applications to reversed-phase gradient separations of biopolymers are not straightforward because of specific problems, such as slow diffusion, limited accessibility of the stationary phase for larger molecules, or possible sample conformation changes during the elution.We used high performance liquid chromatography to investigate the reversed-phase chromatographic behaviour of 14 proteins. The first step was the determination of the experimental data, and then these data were used to predict gradient retention times. A water-organic solvent-trifluoroacetic acid system was used to examine the influence of experimental parameters. The chromatographic results from four C18-chain-length supports were comparable.
Protein molecules present more complex analytical challenges than conventional low molecular weight pharmaceutical compounds, and thus need powerful analytical approaches for the entire pharmaceutical development and quality control process. We used high-performance liquid chromatography to investigate the reversed-phase chromatographic behavior of eleven proteins (albumin, carbonic anhydrase, cytohrome c, L-glutamic dehydrogenase, enolase, α-lactoglobulin, Lysozyme, myoglobin and ribonuclease. By using a water/organic solvent/trifluoroacetic acid system the influence of experimental parameters was examined, and chromatographic results from two C4-chain-length supports were found to be comparable. The model enables prediction of initial conditions from two experimental data points for different types of reversed-phase columns with water-acetonitrile-TFA, water-methanol-TFA, and water-2-propanol-TFA mobile phases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.