Borg's rating of perceived exertion (RPE) is a widely used psycho-physical tool to assess subjective perception of effort during exercise. We evaluated the association between Borg's RPE and physiological exercise parameters in a very large population. In this cohort study, 2,560 Caucasian men and women [median age 28 (IQR 17-44) years] completed incremental exercise tests on treadmills or cycle ergometers. Heart rate, blood lactate concentration, and RPE (Borg scale 6-20) were simultaneously measured at the end of each work load. Rating of perceived exertion was strongly correlated with heart rate (r = 0.74, p < 0.001) and blood lactate (r = 0.83, p < 0.001). The mean values for lactate threshold (LT) and individual anaerobic threshold corresponded to an RPE of 10.8 ± 1.8 and 13.6 ± 1.8, respectively. Fixed lactate thresholds of 3 and 4 mmol/L corresponded to RPEs of 12.8 ± 2.1 and 14.1 ± 2.0. Gender, age, coronary artery disease (CAD), physical activity status and exercise testing modality did not influence this association significantly (all p > 0.05). Borg's RPE seems to be an affordable, practical and valid tool for monitoring and prescribing exercise intensity, independent of gender, age, exercise modality, physical activity level and CAD status. Exercising at an RPE of 11-13 ("low") is recommended for less trained individuals, and an RPE of 13-15 may be recommended when more intense but still aerobic training is desired.
The ability to measure physical activity through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. The aim of this work is to assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males, greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. In conclusion, most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices ().
Precision health relies on the ability to assess disease risk at an individual level, detect early preclinical conditions and initiate preventive strategies. Recent technological advances in omics and wearable monitoring enable deep molecular and physiological profiling and may provide important tools for precision health. We explored the ability of deep longitudinal profiling to make health-related discoveries, identify clinically relevant molecular pathways, and impact behavior in a prospective longitudinal cohort (
n
= 109) enriched for risk of type 2 diabetes mellitus (DM). The cohort underwent integrative Personalized Omics Profiling (iPOP) from samples collected quarterly for up to 8 years (median 2.8 years) using clinical measures and emerging technologies including genome, immunome, transcriptome, proteome, metabolome, microbiome, and wearable monitoring. We discovered over 67 clinically actionable health discoveries and identified multiple molecular pathways associated with metabolic, cardiovascular and oncologic pathophysiology. We developed prediction models for insulin resistance using omics measurements illustrating their potential to replace burdensome tests. Finally, study participation lead the majority of participants to implement diet and exercise changes. Altogether, we conclude that deep longitudinal profiling can lead to actionable health discoveries and provide relevant information for precision health.
IMPORTANCEEndurance exercise is effective in improving peak oxygen consumption (peak V ˙O2 ) in patients with heart failure with preserved ejection fraction (HFpEF). However, it remains unknown whether differing modes of exercise have different effects. OBJECTIVE To determine whether high-intensity interval training, moderate continuous training, and guideline-based advice on physical activity have different effects on change in peak V ˙O2 in patients with HFpEF.
Background: Improving health-related quality of life is a primary target of therapy for patients with inflammatory bowel disease. Physical activity has been demonstrated to improve health-related quality of life in several patient populations with chronic disease. There are very few studies investigating the effects of physical activity on health-related quality of life in inflammatory bowel disease. The primary purpose of this study is to investigate the effects of 10 weeks of moderate physical activity on health-related quality of life in patients with inflammatory bowel disease. Methods: Thirty patients with mild to moderate IBD (Crohn‘s Disease Activity Index (CDAI) <220 or Rachmilewitz Index (RI) <11) were randomized 1:1 to either supervised moderate-intensity running thrice a week for 10 weeks or a control group who were not prescribed any exercise. Health-related quality of life, symptoms, and inflammation were assessed at baseline and after 10 weeks. Results: Participants were 41 ± 14 years (73% female), had a body mass index of 22.8 ± 4.1 kg/m2, and an average CDAI or RI of 66.8 ± 42.4 and 3.6 ± 3.1. No adverse events occurred during the 10-week training period. Health-related quality of life, reported as IBDQ total score, improved 19% in the intervention group and 8% in the control group. Scores for the IBDQ social sub-scale were significantly improved in the intervention group compared with controls (ΔIBDQsocial = 6.27 ± 5.46 vs. 1.87 ± 4.76, p = 0.023). Conclusion: Patients suffering from moderately active IBD are capable of performing symptom-free regular endurance exercise. Our data support the assumption that PA is feasible in IBD patients. PA may furthermore improve quality of life through improvements in social well-being, and may, therefore, be a useful adjunct to IBD therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.