Among patients with NYHA class II or III heart failure, a wide QRS complex, and left ventricular systolic dysfunction, the addition of CRT to an ICD reduced rates of death and hospitalization for heart failure. This improvement was accompanied by more adverse events. (Funded by the Canadian Institutes of Health Research and Medtronic of Canada; ClinicalTrials.gov number, NCT00251251.).
61).However, for patients at centers with a TTR above the study median, OAC had a marked benefit, reducing vascular events by Ͼ2-fold (relative risk, 2.14; 95% confidence interval, 1.61 to 2.85; PϽ0.0001). Mean TTR also varied between countries from 46% to 78%; relative risk (clopidogrel plus aspirin versus OAC) varied from 0.6 to 3.6 (a 5-fold difference). A population-average model predicted that a TTR of 58% would be needed to be confident that patients would benefit from being on OAC. Conclusions-A wide variation exists in international normalized ratio control, as measured by TTR, between clinical centers and between countries, which has a major impact on the treatment benefit of OAC therapy. For centers and countries, a target threshold TTR exists (estimated between 58% and 65%) below which there appears to be little benefit of OAC over antiplatelet therapy.
Background-Genetic testing can diagnose long-QT syndrome (LQTS) in asymptomatic relatives of patients with an identified mutation; however, it is costly and subject to availability. The accuracy of a simple algorithm that incorporates resting and exercise ECG parameters for screening LQTS in asymptomatic relatives was evaluated, with genetic testing as the gold standard. Methods and Results-Asymptomatic first-degree relatives of genetically characterized probands were recruited from 5 centers.QT intervals were measured at rest, during exercise, and during recovery. Receiver operating characteristics were used to establish optimal cutoffs. An algorithm for identifying LQTS carriers was developed in a derivation cohort and validated in an independent cohort. The derivation cohort consisted of 69 relatives (28 with LQT1, 20 with LQT2, and 21 noncarriers).Mean age was 35Ϯ18 years, and resting corrected QT interval (QTc) was 466Ϯ39 ms. Abnormal resting QTc (females Ն480 ms; males Ն470 ms) was 100% specific for gene carrier status, but was observed in only 48% of patients; however, mutations were observed in 68% and 42% of patients with a borderline or normal resting QTc, respectively. Among these patients, 4-minute recovery QTc Ն445 ms correctly restratified 22 of 25 patients as having LQTS and 19 of 21 patients as being noncarriers. The combination of resting and 4-minute recovery QTc in a screening algorithm yielded a sensitivity of 0.94 and specificity of 0.90 for detecting LQTS carriers. When applied to the validation cohort (nϭ152; 58 with LQT1, 61 with LQT2, and 33 noncarriers; QTcϭ443Ϯ47 ms), sensitivity was 0.92 and specificity was 0.82. Conclusions-A simple algorithm that incorporates resting and exercise-recovery QTc is useful in identifying LQTS in asymptomatic relatives. (Circulation. 2011;124:2187-2194.)
Approximately 10% of ischemic strokes are associated with atrial fibrillation (AF) first diagnosed at the time of stroke. Detecting asymptomatic AF would provide an opportunity to prevent these strokes by instituting appropriate anticoagulation. The AF-SCREEN international collaboration was formed in September 2015 to promote discussion and research about AF screening as a strategy to reduce stroke and death and to provide advocacy for implementation of country-specific AF screening programs. During 2016, 60 expert members of AF-SCREEN, including physicians, nurses, allied health professionals, health economists, and patient advocates, were invited to prepare sections of a draft document. In August 2016, 51 members met in Rome to discuss the draft document and consider the key points arising from it using a Delphi process. These key points emphasize that screen-detected AF found at a single timepoint or by intermittent ECG recordings over 2 weeks is not a benign condition and, with additional stroke factors, carries sufficient risk of stroke to justify consideration of anticoagulation. With regard to the methods of mass screening, handheld ECG devices have the advantage of providing a verifiable ECG trace that guidelines require for AF diagnosis and would therefore be preferred as screening tools. Certain patient groups, such as those with recent embolic stroke of uncertain source (ESUS), require more intensive monitoring for AF. Settings for screening include various venues in both the community and the clinic, but they must be linked to a pathway for appropriate diagnosis and management for screening to be effective. It is recognized that health resources vary widely between countries and health systems, so the setting for AF screening should be both country- and health system-specific. Based on current knowledge, this white paper provides a strong case for AF screening now while recognizing that large randomized outcomes studies would be helpful to strengthen the evidence base.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.