SUMMARYObjective: Stereo-electroencephalography (SEEG) is a procedure performed for patients with intractable epilepsy in order to anatomically define the epileptogenic zone (EZ) and the possible related functional cortical areas. By avoiding the need for large craniotomies and due to its intrinsic precision placement features, SEEG may be associated with fewer complications. Nevertheless, intracerebral electrodes have gained a reputation of excessive invasiveness, with a "relatively high morbidity" associated with their placement. A systematic literature review and meta-analysis of SEEG complications has not been previously performed. The goal of this study is to quantitatively review the incidence of various surgical complications associated with SEEG electrode implantation in the literature and to provide a summary estimate. This will allow physicians to accurately counsel their patients about the potential complications related to this method of extraoperative invasive monitoring. Methods: The systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). We conducted MEDLINE, Scopus, and Web of Science database searches with the search algorithm. We analyzed complication rates using a fixed-effects model with inverse variance weighting. Calculations for the meta-analysis and construction of forest plots were completed using an established spreadsheet. The principal summary measures were the effect summary value and 95% confidence intervals (CIs). Results: The initial 1,901 retrieved citations were reviewed. After removing 787 duplicates, the titles and abstracts of 1,114 publications were screened. At this stage, studies that did not mention the absence or presence of complications following SEEG or that did not fulfill the inclusion criteria in any manner were excluded. After excluding 1,057 citations, the full text was assessed in the resulting 57 articles for eligibility criteria. The most common complications were hemorrhagic (pooled prevalence 1.0%, 95% confidence interval [CI] 0.6-1.4%) or infectious (pooled prevalence 0.8%, 95% CI 0.3-1.2%). Five mortalities were identified (pooled prevalence 0.3%, 95% CI À0.1-0.6%). Overall, our analysis identified 121 surgical complications related to SEEG insertion and monitoring (pooled prevalence 1.3%, 95% CI 0.9-1.7%). Significance: This review represents a comprehensive estimation of the actual incidence of complications related to SEEG. We report a rate substantially lower than the complication rates reported for other methods of extraoperative invasive monitoring. These data should alleviate the concerns of some regarding the safety of the "stereotactic" method, allowing a better decision process among the different methods of
Object Despite its long-reported successful record, with almost 60 years of clinical use, the technical complexity regarding the placement of stereoelectroencephalography (SEEG) depth electrodes may have contributed to the limited widespread application of the technique in centers outside Europe. The authors report on a simplified and novel SEEG surgical technique in the extraoperative mapping of refractory focal epilepsy. Methods The proposed technique was applied in patients with medically refractory focal epilepsy. Data regarding general demographic information, method of electrode implantation, time of implantation, number of implanted electrodes, seizure outcome after SEEG-guided resections, and complications were prospectively collected. Results From March 2009 to April 2012, 122 patients underwent SEEG depth electrode implantation at the Cleveland Clinic Epilepsy Center in which the authors' technique was used. There were 65 male and 57 female patients whose mean age was 33 years (range 5–68 years). The group included 21 pediatric patients (younger than 18 years). Planning and implantations were performed in a single stage. The time for planning was, on average, 33 minutes (range 20–47 minutes), and the time for implantation was, on average, 107 minutes (range 47–150 minutes). Complications related to the SEEG technique were observed in 3 patients. The calculated risk of complications per electrode was 0.18%. The seizure-free rate after SEEG-guided resections was 62% in a mean follow-up period of 12 months. Conclusions The authors report on a safe, simplified, and less time-consuming method of SEEG depth electrode implantation, using standard and widely available surgical tools, making the technique a reasonable option for extraoperative monitoring of patients with medically intractable epilepsy in centers lacking the Talairach stereotactic armamentarium.
This technique, using a combination of Visualase laser ablation, ROSA robot, and intraoperative MRI, facilitated a safe, efficacious, efficient, and minimally invasive approach that could be used for placement of 1 or multiple electrodes in the future.
The SEEG methodology is safe and should be considered in children/adolescents with difficult-to-localize epilepsy. When applied to highly complex and difficult-to-localize pediatric patients, SEEG may provide an additional opportunity for seizure freedom in association with a low morbidity rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.