Aim-To examine the reproducibility of crown-heel length measurement; the precision and reproducibility of knee-heel length measurement; and the association between the two in healthy preterm infants. Methods-Paired crown-heel and kneeheel lengths were measured on 172 occasions by three observers in 43 preterm infants between 205 and 458 days of postconceptional age. Results-Crown-heel length (CHL) measurement was highly reproducible, with a coeYcient of variation (CV) of 0.41%. Knee-heel length (KHL) measurement was relatively precise (CV 0.78%), but less reproducible (intra-observer CV 1.77%, intra-observer CV 2.11%), especially in larger infants. The association between KHL and CHL was not consistent and varied with age. KHL was a poor predictor of CHL, with a 95% predictive interval of ± 27.5 mm. Conclusions-KHL was less reproducible than CHL, especially in larger infants, and a poor predictor of CHL. (Arch Dis Child Fetal Neonatal Ed 1999;81:F50-F55)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.