Background:Suture button fixation of syndesmotic injury is growing in popularity, as it has been shown to provide adequate stability in a more cost-effective manner than screw fixation while allowing more physiologic distal tibiofibular joint motion. However, the optimal repair technique and implant orientation have yet to be determined.Purpose/Hypothesis:The purpose of this study was to biomechanically compare 3 suture button construct configurations/orientations for syndesmosis fixation: single, parallel, and divergent. The authors hypothesized that all 3 methods would provide adequate stabilization but that the divergent technique would be the most stable.Study Design:Controlled laboratory study.Methods:The fixation strengths of 3 stabilization techniques with suture button devices were compared with 10 cadaveric legs each (N = 30). Ankle motion under cyclic loading was measured in multiple planes: first in the intact state, then following simulated syndesmosis injury, and then following fixation with 1 of 3 randomly assigned constructs—1 suture button, 2 suture buttons in parallel, and 2 divergent suture buttons. Finally, axial loading with external rotation was applied to failure.Results:All syndesmotic fixation methods provided stability to the torn state. There was no statistically significant difference among the 3 fixation techniques in biomechanical stability. Failure most commonly occurred through fibular fracture at supraphysiologic loads.Conclusion:Suture button implant fixation for syndesmotic injury appears to provide stability to the torn syndesmosis, and the configuration of the fixation does not appear to affect the strength or security of the stabilization.Clinical Relevance:This study provides further insight into the biomechanics and optimal configuration of suture button fixation of the torn syndesmosis. Based on these results, the addition of a second suture button may not significantly contribute to immediate postoperative stability.
Category: Midfoot/Forefoot; Diabetes; Other Introduction/Purpose: Non-traumatic lower extremity amputations (LEA), especially those performed in dysvascular and diabetic patients, are known to have poor long-term prognosis. Perioperative mortality has been reported at between 4 and 10%, and the 1 and 5 year mortality rates range between 22-33% and 39-69%, respectively. While poor outcomes in these patients have been described, there is no consensus as to the predictors of mortality. The purpose of the study is to determine the percentage of patients who had a complication following transmetatarsal amputation (TMA) and identify associated risk factors for complications and mortality. Methods: We queried our institution’s administrative database to identify 247 TMA procedures performed in 229 patients between January, 2002 and December, 2016. Electronic health records were reviewed to document complications defined as reoperation, amputation and mortality. Mortality was also verified using the National Death Index. Additionally, we recorded risk factors including diabetes, A1c level, end stage renal disease (ESRD), cardiovascular disease (CVD), peripheral vascular disease (PVD), history of revascularization, contralateral amputation, and neuropathy. The majority of the study patients were males (157, 69%) and the average age was 57 years (range 24-91). The median BMI was 28 (range 16-58) and 29% of the study patients were obese with a BMI ≥ 30. Fishers Exact tests were used to compare categorical variables. Kruskal-Wallis and Independent T-tests were used to compare numeric data. All data were analyzed using SAS/STAT software version 9.4 (Carey, NC) and a 0.05 level of significance was defined apriori. Results: The conversion rate to below (BKA) or above knee amputation (AKA) was 26% (64 of 247). Males (p=.0274), diabetics (p=.0139), patients in ESRD (p=.019), and patients with a history of CVD (p=.0247) or perioperative revascularization (p=.022) were more likely to undergo further amputation following an index TMA. BMI was significantly higher in patients requiring BKA/AKA (p=.0305). There were no significant differences in age (p=.2723) or A1c levels (p=.4219). The overall mortality rate was 35% (84 of 229). Diabetes (p=.0272), ESRD (p=.0031), history of CVD (p<.0001) or PVD (p=.0179) were all significantly associated with mortality. Patients who died were significantly older (p=.0006) and had significantly higher A1c levels (p=.0373). BMI was not significantly associated with mortality. Twenty-two patients who had 23 further amputations subsequently died. Conclusion: In our series of patients undergoing TMA, 26% underwent further amputation and 35% of patients died. Conversion rate to BKA or AKA occurred at a high rate regardless of preoperative revascularization or the use of tendo-achilles or gastrocnemius lengthening procedures. Male sex, diabetes, ESRD, history of CVD or revascularization are significant risk factors for further amputation. ESRD, diabetes, history of CVD or PVD, older age and higher A1c levels are significant risk factors for mortality. These data provide useful insight into risk factors to be emphasized when counseling patients and their families to establish realistic postoperative expectations.
Category: Diabetes Introduction/Purpose: Despite the presence of several studies examining the conversion from transmetatarsal amputation (TMA) to a more proximal amputation, few studies identified the possible predictors of failure. The objective of this study is to examine the rate of conversion of transmetatarsal amputation to below or above knee amputation, and to identify the risk factors for conversion. Methods: A retrospective cohort study was performed examining 71 transmetatarsal amputations performed by a single group of foot and ankle subspecialists within a single specialty group between October 1 2005 and August 25 2015. Demographic information and comorbidities were recorded, as were complications, readmission rate, and rate of conversion to a more proximal amputation. Results: Of the 71 patients who underwent transmetatarsal amputation during the study period, 74.7% progressed to a revision amputation or more proximal amputation at a mean of 9.7 months, but a median of only 3.2 months. 87.3% progressed to below knee amputation, 9.9% underwent revision transmetatarsal amputation, and 2.8% received an above knee amputation. Of the patients who progressed to more proximal amputation, 88.2% had diabetes mellitus, 72.4% had a pre-operative ulceration, and 81.7% had peripheral neuropathy. Only 52.7% had diagnosed peripheral vascular disease, 38.1% had a history of renal disease, and 35% were smokers. Conclusion: Transmetatarsal amputation has an extremely high short-term reamputation rate with the vast progressing to a below knee amputation. Comorbidities such as diabetes mellitus, neuropathy, and history of ulceration are often found in these patients, while renal and peripheral vascular disease as well as tobacco abuse are not necessarily present. This high rate of reamputation may bring into question the efficacy of performing transmetatarsal amputation as opposed to a more proximal amputation as a definitive procedure when lower extremity amputation is required.
Category: Hindfoot Introduction/Purpose: Hindfoot arthrodesis is often the treatment of choice for hindfoot pain due to arthritis or advanced deformity. Good results are dependent on secure fixation while avoiding hardware related side effects. A small radiolucent locking dorsal circular plate placed into the talonavicular and calcaneocuboid joints may provide a low-profile solution for secure fixation of these joints. The goal of this study is to compare the fixation strength of a locking dorsal circular plate to that of the current gold standard technique of screw fixation. Methods: Eight matched fresh-frozen cadaveric foot-ankle pairs were obtained for comparison of the two fixation methods. One side of each matched pair was plated with a locking dorsal circular plate and the contralateral foot was fixed with partially threaded 4.5 mm cannulated screws. All subtalar joints were fixed with two 7.3 mm cannulated screws. Translational forces through a mechanical testing system (MTS) were applied to the constructs cyclically for 40 cycles followed by loading to failure. Displacement was recorded using two high-speed infrared cameras, following sets of orthogonal marker systems attached to each bone. Results: Cyclical loading trials found there to be no significant difference in resistance to motion between the two methods. However, specimens instrumented with plates had an approximately 400% higher load to failure (513.3 N vs 127.7 N) than specimens instrumented with screws. Conclusion: Locking dorsal circular plates are a viable option that provide equivalent and possibly better fixation strength than screw fixation for the talonavicular and calcaneocuboid components of a triple arthrodesis of the hindfoot. These plates are radiolucent allowing easy assessment of the fusion site. In addition, these plates have the theoretical benefit of being low profile to decrease tendon irritation and wound healing problems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.