Several methods exist for measuring medication adherence. The Time4MedTM device (Adherence Innovations, Hong Kong) is a small, electronic card to affix on medication packaging that records date and time of intakes when a button is pushed. We aimed to validate the device with an emphasis on polypharmacy. Twenty volunteers used Time4MedTM devices with a virtual thrice daily intake over 14 days. Diary-recorded date and time were compared to electronically-stored events. Functionality, reliability and recovery for different stress conditions were calculated. User‘s acceptability was assessed with the System Usability Scale (SUS). Eleven elderly outpatients (mean age 80.2 ± 8.1 years) taking >3 medications daily used the device over 4 weeks. Volunteers logged 847 events. Functionality (100%), sensitivity (94.9%), specificity (99.4%) and recovery (100%) were high. Dropping the smart card and storing it in a refrigerator caused either the recording of false events or no recording at all. The mean SUS score was 82.6 (SD 14.8), demonstrating excellent acceptability. Satisfaction was very high for volunteers and patients, except for pushing the button. Time4MedTM devices are highly accurate in recording, retaining and delivering electronic data of multiple medication intake. They are well accepted by elderly patients. They can be recommended in clinical studies and for practitioners who desire to elucidate adherence patterns of ambulatory patients.
Background: To assess adherence to and preference for vitamin D substitution with different pharmaceutical forms and frequencies of administration. Methods: A focus group of stakeholders aimed at preparing the design of an interventional, randomized, crossover study with 2 × 2 groups obtaining monthly or weekly vitamin D products in liquid or solid form for 3 months each. Dosage corresponds to cumulated amount of recommended 800 IU daily (5.600 IU weekly / 24.000 IU monthly). Main inclusion criteria were a vitamin D serum value < 50 nmol/l and age ≥ 18 years. Primary endpoint was adherence, secondary endpoints were preferences and vitamin D serum levels. Results: The focus group reached consensus for preference of a monthly administration of solid forms to adults. Full datasets were obtained from 97 participants. Adherence was significantly higher with monthly (79.5-100.0%) than weekly (66.4-98.1%) administration. Vitamin D levels increased significantly (p < 0.001) in all participants. An optimal value of > 75 nmol/l was achieved by 32% after 3 months and by 50% after 6 months. Preferred formulation was solid form (tablets, capsules) for 71% of participants, and preferred dosage frequency was monthly for 39% of participants. Conclusions: Monthly oral vitamin D in solid form lead to the highest adherence, and is preferred by the participants. However, only one third of study participants achieved values in the optimal range of > 75 nmol/l cholecalciferol using weekly or monthly administration providing an average daily cholecalciferol dose of 800 IU.
Comparison of several regimens of oral vitamin D including an individually calculated loading regimen with the aim of achieving serum values > 75 nmol/l. Interventional, randomized, 3-arm study in vitamin D-deficient outpatients. Participants were allocated to supplementation of 24,000 IU vitamin D monthly over three months, using either a monthly drinking solution (Vi-De 3) or capsule (D3 VitaCaps), or an individualized loading regimen with the capsules taken weekly. For the loading regimen, the cumulative dose was calculated according to baseline 25-hydroxy-vitamin D (25(OH)D) serum value and body weight. Main inclusion criteria were age ≥ 18 years and 25(OH)D serum concentration < 50 nmol/l. The primary outcome was 25(OH)D serum concentration one week after treatment termination. Secondary endpoints were patient’s preferences and adverse events. Full datasets were obtained from 52 patients. Mean 25(OH)D values were statistically significant higher after a loading regimen compared to a monthly administration of 24,000 IU vitamin D (76.4 ± 15.8 vs 61.4 ± 10.8 nmol/l; p < 0.01). All patients treated with the loading regimen reached sufficient 25(OH)D values > 50 nmol/l. Serum 25(OH)D values > 75 nmol/l were observed more frequently in patients taking the loading regimen (47% vs 11% drinking solution vs 12% capsules). Vitamin D-related adverse effects did not occur in any treatment groups. Capsules were preferred by 88.5% of the patients. Compared to treatments with monthly intake of 24,000 IU vitamin D, the intake of an individually calculated weekly loading regimen was able to raise serum concentrations > 50 nmol/l in all cases within a safe range.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.