Numerical models of the mitral valve have been used to elucidate mitral valve function and mechanics. These models have evolved from simple two-dimensional approximations to complex three-dimensional fully coupled fluid structure interaction models. However, to date these models lack direct one-to-one experimental validation. As computational solvers vary considerably, experimental benchmark data are critically important to ensure model accuracy. In this study, a novel left heart simulator was designed specifically for the validation of numerical mitral valve models. Several distinct experimental techniques were collectively performed to resolve mitral valve geometry and hemodynamics. In particular, micro-computed tomography was used to obtain accurate and high-resolution (39 µm voxel) native valvular anatomy, which included the mitral leaflets, chordae tendinae, and papillary muscles. Threedimensional echocardiography was used to obtain systolic leaflet geometry for direct comparison of resultant leaflet kinematics. Stereoscopic digital particle image velocimetry provided all three components of fluid velocity through the mitral valve, resolved every 25 ms in the cardiac cycle. A strong central filling jet was observed during peak systole, with minimal out-of-plane velocities (V~0.6m/s). In addition, physiologic hemodynamic boundary conditions were defined and all data were synchronously acquired through a central trigger. Finally, the simulator is a precisely controlled environment, in which flow conditions and geometry can be systematically prescribed and resultant valvular function and hemodynamics assessed. Thus, these data represent the first comprehensive database of high fidelity experimental data, critical for extensive validation of mitral valve fluid structure interaction simulations.
The mitral valve is a complex apparatus with multiple constituents that work cohesively to ensure unidirectional flow between the left atrium and ventricle. Disruption to any or all of the components-the annulus, leaflets, chordae, and papillary muscles-can lead to backflow of blood, or regurgitation, into the left atrium, which deleteriously effects patient health. Through the years, a myriad of surgical repairs have been proposed; however, a careful appreciation for the underlying structural mechanics can help optimize long-term repair durability and inform medical device design. In this review, we aim to present the experimental methods and significant results that have shaped the current understanding of mitral valve mechanics. Data will be presented for all components of the mitral valve apparatus in control, pathological, and repaired conditions from human, animal, and in vitro studies. Finally, current strategies of patient specific and noninvasive surgical planning will be critically outlined.
Purpose Computational models of the heart’s mitral valve (MV) exhibit potential for preoperative surgical planning in ischemic mitral regurgitation (IMR). However challenges exist in defining boundary conditions to accurately model the function and response of the chordae tendineae to both IMR and surgical annuloplasty repair. Towards this goal, a ground-truth data set was generated by quantifying the isolated effects of IMR and mitral annuloplasty on leaflet coaptation, regurgitation, and tethering forces of the anterior strut and posterior intermediary chordae tendineae. Methods MVs were excised from ovine hearts (N=15) and mounted in a pulsatile heart simulator which has been demonstrated to mimic the systolic MV geometry and coaptation of healthy and chronic IMR sheep. Strut and intermediary chordae from both MV leaflets (N=4) were instrumented with force transducers. Tested conditions included a healthy control, IMR, oversized annuloplasty, true-sized annuloplasty, and undersized mitral annuloplasty. A2-P2 leaflet coaptation length, regurgitation, and chordal tethering were quantified and statistically compared across experimental conditions. Results IMR was successfully simulated with significant increases in MR, tethering forces for each of the chordae, and decrease in leaflet coaptation (p<.05). Compared to the IMR condition, increasing levels of downsized annuloplasty significantly reduced regurgitation, increased coaptation, reduced posteromedial papillary muscle strut chordal forces, and reduced intermediary chordal forces from the anterolateral papillary muscle (p<.05). Conclusions These results provide for the first time a novel comprehensive data set for refining the ability of computational MV models to simulate IMR and varying sizes of complete rigid ring annuloplasty.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.