In this work, we propose a simple method to simultaneously match the refractive index and kinematic viscosity of a circulating blood analog in hydraulic models for optical flow measurement techniques (PIV, PMFV, LDA, and LIF). The method is based on the determination of the volumetric proportions and temperature at which two transparent miscible liquids should be mixed to reproduce the targeted fluid characteristics. The temperature dependence models are a linear relation for the refractive index and an Arrhenius relation for the dynamic viscosity of each liquid. Then the dynamic viscosity of the mixture is represented with a Grunberg-Nissan model of type 1. Experimental tests for acrylic and blood viscosity were found to be in very good agreement with the targeted values (measured refractive index of 1.486 and kinematic viscosity of 3.454 milli-m2/s with targeted values of 1.47 and 3.300 milli-m2/s).
The purpose of this study was to determine whether the use of a scalpel or electrocautery to remove radioactive sealed sources ("seeds") from surgically excised tissue could damage the seed and cause it to leak its radioactive contents. Attempts were made to cut or burn Oncura Model 6711 non-radioactive seeds while in pig muscle or on a stainless steel plate. Additionally, one active 125I seed was purposely charred using pressure with an electrocautery knife to see whether the casing could be damaged. Electron microscopy scanning was performed on the dummy seeds to determine if the integrity of the metal casing had been compromised. Two types of leak tests were performed on the active seed to verify the presence or absence of loose contamination. The seed casing was not damaged from either use of a scalpel or electrocautery when the seed was in tissue. The active seed was not found to be leaking after applying pressure with an electrocautery knife while the seed was on a stainless steel plate. We conclude that removal of active Model 6711 seeds from surgically excised tissue can be done safely with a scalpel or electrocautery because constant, firm pressure cannot be applied to the seed. This is likely true for seeds made of similar materials.
Background: Several contrast media (CM) are used for diagnostic angiography and coronary percutaneous interventions. Catheter miniaturization allows performance of most diagnostic studies using 4-5 F catheters and interventions using 5-6 F catheters. As a result of catheter lumen downsizing and viscosity of CM, the operators are sometimes required to forcefully inject to produce adequate images. Methods and Results: The aim of the study is to perform a comparative rheology analysis between three different commonly used CM: iso-osmolar, nonionic iodixanol, Visipaque 1 , (GE Healthcare); low-osmolar, nonionic ioversol, Optiray 1 ; and low-osmolar, ionic ioxaglate, Hexabrix 1 , (Tyco Healthcare, US). The viscosity was experimentally assessed for temperature varying from 14 to 408C. To reproduce clinical use, an experimental set-up was used and the pressure developed to inject CM was evaluated at different temperatures and compared between the three CM. All three agents demonstrated a nonlinear inverse relationship between temperature and viscosity. At 148C iodixanol showed a twofold increase in viscosity compared with ioversol and ioxaglate. At 408C, the difference was reduced to 27%. At room temperature (208C), the difference in pressure needed to inject CM was 10% between iodixanol and ioxaglate and 6% between iodixanol and ioversol. As the temperatures increased, the differences in pressure became less important, becoming negligible (1%) at 378C. Conclusion: The viscosity of the iso-osmolar nonionic contrast agent iodixanol showed a stronger dependence on temperature compared with ioversol and ioxaglate. The impact of differences in viscosity and pressure to inject between CM were minimized at 378C. This emphasizes the importance of temperature control when using current lowosmolar CM and iso-osmolar CM with smaller sized catheters. '
Cardiovascular diseases are the leading cause of morbidity and mortality in Canada and other western countries. In that context, understanding the mechanics involved in the aorta can lead to better comprehension of the interaction of blood flow and wall mechanics in normal and pathologic conditions. In this work, we present the methodologies to create physical models of the aorta for flow visualization purposes in order to assess the effects of compliance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.