BACKGROUND:This study assessed the clinical sensitivity of three fully automated, human immunodeficiency virus (HIV), hepatitis C virus (HCV), and hepatitis B virus (HBV) triplex nucleic acid test (NAT) assays by individual donation (ID-NAT) and at operational minipool (MP-NAT) sizes used worldwide. STUDY DESIGN AND METHODS: MPX, Ultrio, and Ultrio Plus were used to test 2222 pedigreed, markerpositive samples with varying viral loads, each from a unique US blood donor. NAT-positive, seronegative yield samples (16 HBV, 156 HCV, and 23 HIV) were tested in replicates of three; undiluted; and in 1:6, 1:8, and 1:16 dilutions (MP6, MP8, and MP16), simulating various MP sizes. Seropositive samples (1276 HBV, 488 HCV, and 263 HIV) were tested by ID-NAT in singlet. RESULTS: MPX-MP6 and Ultrio Plus-MP16 had equivalent HCV sensitivity. Although Ultrio Plus-MP16 for HIV trended toward lesser sensitivity, this was not corroborated in a large substudy of low-viral-load samples in which Ultrio Plus-MP8/MP16 showed 100% reactivity. MPX-ID and Ultrio Plus-ID HBV clinical sensitivity were identical, but MPX-MP6 was significantly more sensitive than Ultrio Plus-MP16; the differential yield projected to one HBV NAT yield per 4.72 million US donations. Ultrio Plus HBV sensitivity did not increase at MP8 versus MP16. Ultrio Plus versus Ultrio sensitivity was significantly increased in HBV-infected donors with early acute, late acute or chronic, and occult infections. No difference in sensitivity was noted for any virus for MPX-MP6 versus Ultrio Plus-ID. CONCLUSIONS: Our data support US donation screening with MPX-MP6 or Ultrio Plus-MP16 since the HBV DNA detection of Ultrio Plus was significantly enhanced (vs. Ultrio) without compromising HIV or HCV RNA detection.
Screening of U.S. blood donations for ZIKV by individual-donation TMA was costly and had a low yield. Among the 9 confirmed ZIKV-positive donations, only 4 were IgM-negative; of these donations, all 3 that were tested were reactive on minipool TMA. (Funded by the American Red Cross and Grifols Diagnostic Solutions.).
ABBREVIATIONS: ARC = American Red Cross; BSL = Blood Systems Laboratories; ID(s) = individual-donation(s); MP(s) = minipool(s); S/CO = signal-to-cutoff optical density ratio; TMA = transcription-mediated amplification.
BACKGROUND:The routine use of hepatitis C virus (HCV) nucleic acid amplification testing (NAT) donor screening assays has provided an opportunity for revision of the current HCV supplemental testing algorithm, which requires that recombinant immunoblot assay (RIBA) be performed on every HCV enzyme immunoassay (EIA)-repeat-reactive donation. The FDA has approved variance requests to use a new algorithm that eliminates the need to perform RIBA when HCV NAT results are reactive. Data are provided in support of this new algorithm. STUDY DESIGN AND METHODS: HCV EIA (including signal-to-cutoff optical density ratio), RIBA, and NAT data were compiled from 33.2 million donations screened over an approximately 4-year period by the American Red Cross and Blood Systems Laboratories. Further, donations having specific combinations of HCV EIA, RIBA, and minipool (MP) NAT results were evaluated, with more sensitive individual-donation (ID) NAT, to construct improved counseling messages for donors. RESULTS: Of 47,041 EIA-repeat-reactive donations, 49.3 percent were RIBA-positive, 17.1 percent RIBAindeterminate, and 33.5 percent RIBA-negative. NATreactive rates were 79.2, 2.5, and 0.18 percent for RIBApositive, -indeterminate, and -negative donations, respectively. The new algorithm classified an additional 1 percent of donations as HCV-infected while at the same time detecting all infections classified as HCV-infected under the current algorithm. An additional 2.4 percent of RIBApositive, MP NAT-nonreactive donations were reactive when a frozen-thawed aliquot was retested by ID NAT. CONCLUSION: Integrating HCV NAT results with RIBA results for purposes of donor notification allows more appropriate counseling messages to be given to EIArepeat-reactive donors. The new HCV supplemental algorithm is an acceptable alternative to the current algorithm because it provides equivalent or superior accuracy in formulating donor counseling messages and may also result in reduced costs and more timely notification of infected donors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.