An important percentage of patients undergoing total hip replacement (THR) receive allogeneic blood transfusion (ABT) to avoid the risks of acute anaemia. However, concerns about the risks of ABT have led to the search for alternatives, such as stimulation of erythropoiesis. We prospectively investigated the effect of postoperative administration of 300 mg of intravenous iron sucrose on ABT requirements in THR patients (group 2; n = 24). A previous series of 22 THR patients served as the control group (group 1). All patients were operated on by the same surgeon, using the same implant, and a set of clinical data was gathered. No adverse reactions to iron administration were observed. The group-given iron showed a trend to a lower transfusion rate (46 vs. 73%; P = 0.067) and lower transfusion index (0.96 vs. 1.68 units/patient; P = 0.038). Moreover, amongst the non-transfused patients, admission haemoglobin levels were lower in those coming from the iron group than those from the control group (12.7 +/- 0.9 vs. 14.0 +/- 1.2 g dL(-1), respectively; P = 0.017). Postoperative parenteral iron administration could be a safe and effective way to reduce ABT requirements in the THR patients. A large, randomized controlled trial to confirm these results is warranted.
The transition to AF after CTI AFL ablation was high during a long-term follow-up period and maintained over time. Prior AF and COPD were the primary predictors of transition to AF after CTI AFL ablation. Patients who transitioned to AF had an increased risk of stroke and a more than twofold mortality rate. These clinical implications make it necessary to investigate AF after CTI ablation.
AimRight ventricular pacing (VP) has been hypothesized to increase the risk in heart failure (HF) and atrial fibrillation (AF). The ANSWER study evaluated, whether an AAI-DDD changeover mode to minimize VP (SafeR) improves outcome compared with DDD in a general dual-chamber pacemaker population.Methods and resultsANSWER was a randomized controlled multicentre trial assessing SafeR vs. standard DDD in sinus node disease (SND) or AV block (AVB) patients. After a 1-month run-in period, they were randomized (1 : 1) and followed for 3 years. Pre-specified co-primary end-points were VP and the composite of hospitalization for HF, AF, or cardioversion. Pre-specified secondary end-points were cardiac death or HF hospitalizations and cardiovascular hospitalizations. ANSWER enrolled 650 patients (52.0% SND, 48% AVB) at 43 European centres and randomized in SafeR (n = 314) or DDD (n = 318). The SafeR mode showed a significant decrease in VP compared with DDD (11.5 vs. 93.6%, P < 0.0001 at 3 years). Deaths and syncope did not differ between randomization arms. No significant difference between groups [HR = 0.78; 95% CI (0.48–1.25); P = 0.30] was found in the time to event of the co-primary composite of hospitalization for HF, AF, or cardioversion, nor in the individual components. SafeR showed a 51% risk reduction (RR) in experiencing cardiac death or HF hospitalization [HR = 0.49; 95% CI (0.27–0.90); P = 0.02] and 30% RR in experiencing cardiovascular hospitalizations [HR = 0.70; 95% CI (0.49–1.00); P = 0.05].ConclusionSafeR safely and significantly reduced VP in a general pacemaker population though had no effect on hospitalization for HF, AF, or cardioversion, when compared with DDD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.