These data support open rotator cuff repair as an effective technique that restores excellent shoulder function. The authors did not find postoperative cuff integrity to have a significant effect on outcomes when compared with those with an intact cuff. In fact, those with a retear still had a significant improvement in all clinical areas assessed, including strength.
Summary:
Social interactions are largely dependent on the interpretation of information conveyed through facial expressions. Although facial reanimation seeks restoration of the facial expression of emotion, outcome measures have not addressed this directly. This study evaluates the use of a machine learning technology to directly measure facial expression before and after facial reanimation surgery. Fifteen study subjects with facial palsy were evaluated both before and after undergoing cross-facial nerve grafting and free gracilis muscle transfer. Eight healthy volunteers were assessed for control comparison. Video footage of subjects with their face in repose and with a posed, closed-lip smile was obtained. The video data were then analyzed using the Noldus FaceReader software application to measure the relative proportions of seven cardinal facial expressions detected within each clip. The facial expression recognition application detected a far greater happy signal in postoperative (42 percent) versus preoperative (13 percent) smile videos (p < 0.0001), compared to 53 percent in videos of control faces smiling. This increase in postoperative happy signal was achieved in exchange for a reduction in the sad signal (15 percent to 9 percent; p = 0.092) and the neutral signal (57 percent to 37 percent; p = 0.0012). For video clips of patients in repose, no significant difference in happy emotion was detected between preoperative (3.1 percent) and postoperative (1.4 percent) states (p = 0.5). This study provides the first proof of concept for the use of a machine learning software application to objectively quantify facial expression before and after surgical reanimation.
CLINICAL QUESTION/LEVEL OF EVIDENCE:
Diagnostic, IV.
Background: Middle and distal insets of gastroepiploic vascularized lymph node transfer (GE-VLNT) for extremity lymphedema have been described. However, there has been no prior comparison of surgical or patient-reported outcomes between these techniques. We analyzed the outcomes between both insets in patients with extremity lymphedema.Methods: Retrospective review of patients with extremity-lymphedema who underwent GE-VLNT. Two groups were analyzed: middle and distal recipient inset. We analyzed 6-month surgical and patient-reported outcomes using the Lymphedema Life Impact Scale-v2 (LLISv2) and scar satisfaction utilizing the Patient Scar Assessment Questionnaire (PSAQ).Results: Between 2017 and 2019, 26 patients with stage II unilateral extremity lymphedema underwent laparoscopically-harvested GE-VLNT (13 distal and 13 middle inset). There were no differences in patient demographics between groups. Mean hospital stay for patients with upper extremity lymphedema was 1.3 vs. 4.0 days (P<0.05), and for lower extremity lymphedema was 1.0 vs. 4.5 days (P<0.05), middle vs. distal inset, respectively. Mean return to daily activities for patients with upper extremity lymphedema was 13.4 vs.33.4 days (P<0.05), and for lower extremity lymphedema was 16.0 vs. 29.5 days (P<0.05), middle vs. distal inset, respectively. Both middle and distal inset showed significant mean excess volume reduction at 6 months postoperatively for both upper and lower extremity lymphedema (upper extremity: middle inset 23.3%, distal inset: 22.0%; lower extremity: middle inset 23.3% and distal inset 13.3%). LLISv2 scores showed improved functional outcomes postoperatively in both upper and lower extremity lymphedema with both insets. Scar satisfaction with appearance and symptoms was higher with middle inset (P<0.05).Conclusions: GE-VLNT is an effective surgical treatment for extremity lymphedema. The middle placement showed shorter hospital stay, early return to work and higher patient satisfaction.
The mean brake reaction time following successful right ankle arthrodesis was significantly slower than that of normal controls. However, the fusion group time was still below the threshold for what is defined as a safe brake reaction time by the United States Federal Highway Administration.
Background: Shear wave elastography (SWE) shows promise in peripheral neuropathy evaluation but has potential limitations due to tissue size and heterogeneity. We tested SWE sensitivity to elasticity change and the effect of probe position in a median nerve cadaver model. Methods: Ten specimens were used to measure median nerve elasticity under increasing loads using SWE and indentation. Measurements were compared using repeated-measures analysis of variance. Results: Indentation and SWE-based longitudinal nerve elasticity increased with tensile loading (P < .01), showing a similar relationship. Acquisition in a transverse plane showed lower values compared with longitudinal measurements, mostly under higher loads (P = .03), as did postdissection elasticity (P = .02). Elasticity did not change when measured proximal to the carpal tunnel. Conclusions: Longitudinal SWE is sensitive to changes in median nerve elasticity. Measuring elasticity of peripheral nerves noninvasively could elucidate intra-neural pathology related to compression neuropathies, and proof to be of added value as a diagnostic or prognostic tool. K E Y W O R D S carpal tunnel syndrome, elastography, nerve elasticity, neurodynamics, peripheral neuropathy
Three-dimensional (3-D) printing offers many potential advantages in
designing and manufacturing plating systems for foot and ankle procedures that
involve small, geometrically complex bony anatomy. Here, we describe the design
and clinical use of a Ti-6Al-4V ELI bone plate (FastForward™ Bone Tether
Plate, MedShape, Inc., Atlanta, GA) manufactured through 3-D printing processes.
The plate protects the second metatarsal when tethering suture tape between the
first and second metatarsals and is a part of a new procedure that corrects
hallux valgus (bunion) deformities without relying on doing an osteotomy or
fusion procedure. The surgical technique and two clinical cases describing the
use of this procedure with the 3-D printed bone plate are presented within.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.