Abstract-A high recurrence rate, and progression to higher stages are observed for patients diagnosed with urothelial carcinoma (previously known as transitional cell carcinoma). Low prognostic value of the current grading systems result in extensive follow-up of patients for multiple years after first diagnosis. Although, the aid of computer systems for prognosis prediction of superficial urothelial carcinomas have been proposed, earlier analyses have been focused on using morphological features of cells and attributes describing the patient. In this study, we propose a system to aid in the prediction of prognostic information based on a texture analysis of histopathological images of superficial urothelial carcinoma. The analyses are conducted using the local binary pattern (LBP) and local variance (VAR) operators followed by a RUSBoost classifier. A dataset of 42 patients, consisting of 13 patients without recurrence, 14 with recurrence but not progression and 15 patients with progression are studied. Using a leave-one-out cross-validation, an accuracy of 70% and sensitivity of 84% is achieved.
Background
Fresh stillbirths (FSB) and very early neonatal deaths (VEND) are important global challenges with 2.6 million deaths annually. The vast majority of these deaths occur in low- and low-middle income countries. Assessment of the fetal well-being during pregnancy, labour, and birth is normally conducted by monitoring the fetal heart rate (FHR). The heart rate of newborns is reported to increase shortly after birth, but a corresponding trend in how FHR changes just before birth for normal and adverse outcomes has not been studied. In this work, we utilise FHR measurements collected from 3711 labours from a low and low-middle income country to study how the FHR changes towards the end of the labour. The FHR development is also studied in groups defined by the neonatal well-being 24 h after birth.
Methods
A signal pre-processing method was applied to identify and remove time periods in the FHR signal where the signal is less trustworthy. We suggest an analysis framework to study the FHR development using the median FHR of all measured heart rates within a 10-min window. The FHR trend is found for labours with a normal outcome, neonates still admitted for observation and perinatal mortality, i.e. FSB and VEND. Finally, we study how the spread of the FHR changes over time during labour.
Results
When studying all labours, there is a drop in median FHR from 134 beats per minute (bpm) to 119 bpm the last 150 min before birth. The change in FHR was significant ($$p<0.05$$
p
<
0.05
) using Wilcoxon signed-rank test. A drop in median FHR as well as an increased spread in FHR is observed for all defined outcome groups in the same interval.
Conclusion
A significant drop in FHR the last 150 min before birth is seen for all neonates with a normal outcome or still admitted to the NCU at 24 h after birth. The observed earlier and larger drop in the perinatal mortality group may indicate that they struggle to endure the physical strain of labour, and that an earlier intervention could potentially save lives. Due to the low amount of data in the perinatal mortality group, a larger dataset is required to validate the drop for this group.
Documentation of fetal to neonatal heart rate (HR) transition is limited. The aim of the current study was to describe HR changes from one hour before to one hour after normal vaginal deliveries. We conducted a prospective observational cohort study in Tanzania from 1 October 2020 to 30 August 2021, including normal vaginal deliveries with normal neonatal outcomes. HR was continuously recorded from one hour before to one hour after delivery, using the Moyo fetal HR meter, NeoBeat newborn HR meter, and the Liveborn Application for data storage. The median, 25th, and 75th HR percentiles were constructed. Overall, 305 deliveries were included. Median (interquartile range; IQR) gestational age was 39 (38–40) weeks and birthweight was 3200 (3000–3500) grams. HR decreased slightly during the last 60 min before delivery from 136 (123,145) to 132 (112,143) beats/minute. After delivery, HR increased within one minute to 168 (143,183) beats/min, before decreasing to around 136 (127,149) beats/min at 60 min after delivery. The drop in HR in the last hour of delivery reflects strong contractions and pushing. The rapid increase in initial neonatal HR reflects an effort to establish spontaneous breathing.
This thesis is based on a collection of five papers, four published and one currently under review. For increased readability, the papers have been reformatted for alignment with the format of the thesis and are included as chapters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.