In mild POSAS with normal EES the new SPT device and the standard TBT are equally effective in reducing respiratory indices. However, compared to the TBT, sleep quality, quality of life, and compliance improved significantly more in the SPT group.
The aim of the study was to investigate the clinical feasibility of whole-brain radiation therapy without a thermoplastic mask. Positioning and intra-fractional motion monitoring were performed using optical surface scanning. The motion threshold was 3 mm/3 degrees. The group mean vector deviation was 1.1 mm. The roll was larger compared to pitch and rotation. Two patients out of 30 were not able to lie still. All other patients completed their treatment successfully without a mask. With a probability of success of 93%, we concluded that irradiation without a mask is a clinically feasible method.
Background
Surface-guided radiotherapy (SGRT) is used to ensure a reproducible patient set-up and for intra-fraction motion monitoring. The arm position of breast cancer patients is important, since this is related to the position of the surrounding lymph nodes. The aim of the study was to investigate the set-up accuracy of the arm of patients positioned using SGRT. Moreover, the actual delivered dose was investigated and an extensive breath-hold analysis was performed.
Methods
84 patients who received local or locoregional breast radiation therapy were positioned and monitored using SGRT. The accuracy of the arm position, represented by the clavicle position, was studied on the anterior–posterior kV-image. To investigate the effect of changes in anatomy and patient set-up, the actual delivered dose was calculated on cone-beam CT-scans (CBCT). A deformable registration of the CT to the CBCT was applied to deform the structures of the CT onto the CBCT. The minimum dose in percentage of the prescribed dose that was received by 98% of different CTV volumes (D98) was determined. An extensive breath-hold analysis was performed and definitions for relevant parameters were given.
Results
The arm position of 77 out of 84 patients in total was successful, based on the clavicle rotation. The mean clavicle rotation was 0.4° (± 2.0°). For 89.8% of the patients who were irradiated on the whole-breast D98 was larger than 95% of the prescribed dose (D98 > 95%). D98 > 95% applied for 70.8% of the patients irradiated on the chest wall. Concerning the lymph node CTVs, D98 > 95% for at least 95% of the patients. The breath-hold analysis showed a mean residual setup error of − 0.015 (± 0.90), − 0.18 (± 0.82), − 0.58 (± 1.1) mm in vertical, lateral, and longitudinal direction, respectively. The reproducibility and stability of the breath-hold was good, with median 0.60 mm (95% confidence interval (CI) [0.66–0.71] mm) and 0.20 mm (95% CI 0.21–0.23] mm), respectively.
Conclusions
Using SGRT we were able to position breast cancer patients successfully, with focus on the arm position. The actual delivered dose calculated on the CBCT was adequate and no relation between clavicle rotation and actual delivered dose was found. Moreover, breath-hold analysis showed a good reproducibility and stability of the breath-hold.
Trial registration CCMO register NL69214.028.19.
Background and purpose: Surface guided radiotherapy can be used to improve patient setup and for accurate intrafraction motion monitoring in correspondence to the isocenter. For a clinical relevant motion analysis the actual displacement of the entire clinical target volume (CTV) is necessary. Therefore, the aim of this study was to develop a novel assessment method for intra-fraction motion for rigid body structures based on motion data and a geometrical analysis. Materials and methods: A threshold value on the volume coverage (VC(t)) of the CTV by the planning target volume (PTV) was proposed as online motion monitoring method. Moreover, offline analysis was performed by using heat maps and by calculating VCx, the volume coverage for at least x% of treatment time. The method was applied retrospectively to patient treatment data for whole brain radiation treatment without a thermoplastic mask. Results: In 132 out of 142 fractions in total the proportion of the CTV that was inside the PTV for at least 99% of the time (VC99) was more than 95%, for a CTV-to-PTV margin of 5 mm. The source-voxel heat map showed which part of the CTV had a reduced coverage and the target heat map showed the movement of the CTV. Conclusion: Instead of using an action threshold on the movements of the isocenter, a threshold on the VC(t) of the CTV by the PTV was proposed. The heat maps and resulting values of VCx can be used to adapt the VC(t) threshold or the CTV-to-PTV margin for subsequent fractions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.