Aims To explore the clinical relevance of joint space width (JSW) narrowing on standardized-flexion (SF) radiographs in the assessment of cartilage degeneration in specific subregions seen on MRI sequences in knee osteoarthritis (OA) with neutral, valgus, and varus alignments, and potential planning of partial knee arthroplasty. Methods We retrospectively reviewed 639 subjects, aged 45 to 79 years, in the Osteoarthritis Initiative (OAI) study, who had symptomatic knees with Kellgren and Lawrence grade 2 to 4. Knees were categorized as neutral, valgus, and varus knees by measuring hip-knee-angles on hip-knee-ankle radiographs. Femorotibial JSW was measured on posteroanterior SF radiographs using a special software. The femorotibial compartment was divided into 16 subregions, and MR-tomographic measurements of cartilage volume, thickness, and subchondral bone area were documented. Linear regression with adjustment for age, sex, body mass index, and Kellgren and Lawrence grade was used. Results We studied 345 neutral, 87 valgus, and 207 varus knees. Radiological JSW narrowing was significantly (p < 0.01) associated with cartilage volume and thickness in medial femorotibial compartment in neutral ( r = 0.78, odds ratio (OR) 2.33) and varus knees ( r = 0.86, OR 1.92), and in lateral tibial subregions in valgus knees ( r = 0.87, OR 3.71). A significant negative correlation was found between JSW narrowing and area of subchondral bone in external lateral tibial subregion in valgus knees ( r = −0.65, p < 0.01) and in external medial tibial subregion in varus knees ( r = −0.77, p < 0.01). No statistically significant correlation was found in anterior and posterior subregions. Conclusion SF radiographs can be potentially used for initial detection of cartilage degeneration as assessed by MRI in medial and lateral but not in anterior or posterior subregions. Cite this article: Bone Joint Res 2021;10(3):173–187.
Purpose The purpose of this study was to investigate the potential of a doubled semitendinosus (ST) and a single gracilis tendon (GT) lateral meniscus autograft to restore the knee joint kinematics and tibiofemoral contact after total lateral meniscectomy (LMM). Methods Fourteen human knee joints were tested intact, after LMM and after ST and GT meniscus autograft treatment under an axial load of 200 N during full range of motion (0°–120°) and four randomised loading situations: without external moments, external rotation, valgus stress and a combination of external rotation and valgus stress using a knee joint simulator. Non-parametric statistical analyses were performed on joint kinematics and on the tibiofemoral contact mechanics. Results LMM led to significant rotational instability of the knee joints (p < 0.02), which was significantly improved after ST autograft application (p < 0.04), except for knee joint flexions > 60°. The GT autograft failed to restore the joint kinematics. LMM significantly increased the tibiofemoral contact pressure (p < 0.03), while decreasing the contact area (p < 0.05). The ST autograft was able to restore the contact mechanics after LMM (p < 0.02), while the GT replacement displayed only an improvement trend. Conclusion The doubled ST lateral meniscus autograft improved the knee joint kinematics significantly and restored the tibiofemoral contact mechanics almost comparable to the native situation. Thus, from a biomechanical point of view, ST meniscus autografts might be a potential treatment alternative for patients who are indicated for meniscus allograft transplantation.
Introduction: Periprosthetic joint infections (PJI) following primary arthroplasty continue to be a serious complication, despite advances in diagnostics and treatment. Two-stage revision arthroplasty has been commonly used as the gold standard for the treatment of PJI. However, much discussion persists regarding the interim of the two-stage procedure and the optimal timing of reimplantation. Serology markers have been proposed as defining parameters for a successful reimplantation. The objective of this matched-pair analysis was to assess the role of serum C-reactive protein (CRP) and white blood cell count (WBC) in determining infection eradication and proper timing of reimplantation. We investigated the delta (∆) change in CRP and WBC values prior to both stages of two-stage revision arthroplasty as a useful marker of infection eradication. Methods: We analyzed 39 patients and 39 controls, matched by propensity score matching (BMI, age, ASA-classification), with a minimum follow-up of 24 months and treated with a two-stage revision THA or TKA in our institution. Data of serum CRP and WBC values were gathered at two selected time points: prior to the explantation of the implant (preexplantation) and following the completion of antibiotic treatment regimen, both systemic and with a drug-eluting cement spacer (prereimplantation). Patient records were reviewed electronically for preexisting comorbidities, overall health status, synovial fluid cultures, inflammatory serologies, revision surgeries, and recurrent or persistent infection based on the modified Musculoskeletal Infection Society criteria. Patient demographics, ∆CRP, ∆WBC, and time interval to reimplantation were statistically analyzed using receiver operator curves (ROC), Pearson’s correlation coefficient, Levene’s test, and Student’s t-test. Results: Infection-free patients exhibited higher mean CRP and WBC than did patients who were reinfected at both time points. When comparing preexplantation with prereimplantation values, the median ∆CRP was 9.48 mg/L (interquartile range (IQR) 2.3–36.6 mg/L) for patients who did not develop a reinfection versus 2.74 mg/L (IQR 1.4–14.2 mg/L) for patients who developed reinfection (p = 0.069). The median ∆WBC was 1.5 × 109/L (IQR 0.6–4.0 × 109/L) for patients who remained infection-free versus 1.2 × 109/L (IQR 0.8–2.2 109/L) for patients who developed reinfection (p = 0.072). Analysis of areas under the curve (AUC) using ROC demonstrated poor prediction of persistent infection by ∆CRP (AUC = 0.654) and ∆WBC (AUC = 0.573). Although a highly significant correlation was found between the interim interval and infection persistence (r = 0.655, p < 0.01), analysis using ROC failed to result in a specific threshold time to reimplantation above which patients are at significantly higher risk for reinfection (AUC = 0.507). Conclusion: No association could be determined between the delta change in serum CRP and WBC before and after two-stage revision arthroplasty for PJI and reinfection risk. Even though inflammatory serologies demonstrate a downtrending pattern prior to reimplantation, the role of CRP and WBC in determining the optimal timing of reimplantation seems to be dispensable. Planning a second-stage reimplantation requires assessing multiple variables rather than relying on specific numeric changes in these inflammatory marker values.
Purpose Meniscectomy may lead to osteoarthritis. Autologous meniscus substitutes such as fat pads, perichondral tissue, facia-covered meniscus fragments and various tendons have been previously investigated for meniscal replacement in animal models. Recently, a clinical pilot study indicated promising outcomes by utilising a doubled semitendinosus tendon autograft. However, to date, no biomechanical data is available regarding this promising treatment alternative. Therefore, the aim of this in-vitro study on human knee joints was to investigate the potential of two autologous tendon meniscus replacements to restore the knee joint kinematics and tibiofemoral contact after total lateral meniscectomy (LMM). Methods The tibiofemoral loads and knee joint kinematics of fourteen left human cadaveric knee joints were investigated using an established knee joint simulator. Testing conditions included the intact, native state, total LMM and replacement using a single-bundle gracilis tendon (GT) and a doubled semitendinosus (ST) meniscus autograft. The joints were axially loaded with 200 N and exposed to no externally applied moments, external rotation, valgus stress and a combination of external rotation and valgus stress during three flexion-extension cycles (0° – 120°). Non-parametric statistical analyses were performed on joint kinematics, the tibiofemoral mean (CPmean) and peak (CPpeak) contact pressures and the contact area (CA). Results LMM led to significant rotational instability of the knee joint (p < 0.02). While the GT autograft procedure failed to restore joint kinematics, the ST autograft did restore the knee joint kinematics, except for knee joint flexions > 60°. The varus-valgus knee alignment was unaltered by any of the interventions. As expected, LMM significantly increased the CPmean and CPpeak (p < 0.03), while decreasing the CA (p < 0.05). The CPpeak was restored by ST autograft application, while the GT replacement displayed only a trend towards contact mechanics improvement compared to LMM. Conclusion The ST autograft displayed promising results in the initial restoration of the basic biomechanical knee joint function after total LMM. Future studies are required to optimise the tendon autograft procedure for total meniscus replacement and also in-vivo or clinical studies to better understand the remodelling process.
Background Diagnosing patellofemoral instability disorders correctly, weight-bearing MRI (WB-MRI) has become an option. Aiming for a best possible accuracy in displaying potentially underlying causes, the named MRI modalities were sporadically even investigated in different knee flexion angles. However, despite confirmed MRI-outcome-differences between WB-MRI and non-WB-MRI, none of the described MRI modalities have so far established themselves. Mainly this is due to an unfeasibility in daily clinical routine in regard to time and economic aspects. Thus, we intended to evaluate an additional but reduced patellofemoral MR-imaging solely in a relevant 20° of knee flexion under WB- and non-WB-MRI conditions. Methods Seventy-three subjects with and without patellofemoral instability were investigated under supine as well as under WB-MRI conditions in a 20° of knee flexion angle. Patellofemoral risk indices in the sagittal plane (Insall-Salvati-Index, Caton-Deschamps-Index, Patellotrochlear Index) and the axial plane (Patella tilt of Fulkerson and Sasaki) were detected and compared between the different MRI conditions. Significance, reliability and Cohen’s effect size was calculated. Results Nearly all assessed indices showed significant differences between patients and controls in the different MRI positions. Comparing pairwise, all measured indices failed to show significant differences between the two MRI positions. However, patella tilt angles of the patient group showed an elevation from supine to WB-MRI (14.00 ± 7.54° to 15.97 ± 9.10° and 16.34 ± 7.84° to 18.54 ± 9.43°). Here, Cohen’s d showed small to medium effects between supine and WB-MRI. Conclusion In comparison to standard MRI in supine position, axial risk indices seem to be accentuated under WB-MRI and a knee flexion angle of 20°. In particular, symptomatic cases with inconspicuous conventional MRI imaging, additional MRI imaging only in the axial plane in a 20° of knee flexion could be beneficious and useful in clinical daily routine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.